Cylinder ports are NAMUR hole pattern. 3-12-4 5 NAMUR Interface 5 Port Solenoid Valve Series VFN2000N/3000N NAMUR Mounting Pattern Axis A-A' can be aligned to suit. A 24 VK M5 thread 8 deep, with or without insert depending on base material. VZ 32 VF A' VFR Coding stud.
A 24 V100 M5 thread 8 deep, with or without insert depending on base material. SY 32 SYJ A' VK Coding stud.
How to Order 10 SY 5 L 5 1 20 01 Clean series Bracket Series Nil: Without bracket F1: With foot bracket A, B port size 3 10-SY3000 5 10-SY5000 Thread piping 2 position single only Coil type Symbol Port size M5 x 0.8 10-SY3000 Applicable series 7 9 10-SY7000 10-SY9000 M5 Standard Nil 1 8 01 10-SY5000 T With power saving circuit (24, 12 VDC only) Actuation type 1 4 10-SY7000 02 02 03 2 position
Be sure to adopt a reliable connecting method if the rotary table is used very frequently or if it is used in a location that is exposed to a large amount of vibrations. Consider the possibility of a reduction in the circuit air pressure caused by a power failure.
Use caution to the popping of a snap ring. When replacing rod seals and removing and mounting a snap ring, use a proper tool (snap ring plier: tool for installing a type C snap ring). Even if a proper tool is used, it is likely to inflict damage to a human body or peripheral equipment, as a snap ring may be flown out of the tip of a plier.
Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be as follows.
Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with a switching element or when a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the leakage voltage passing through the C-R circuit. The suppressor residual leakage voltage should be as follows.
3 y r t !1 A A Enlarged view of A Component Parts Description No.
1 @3 A* A* Component Parts Material Description Remarks No. q w e Aluminum alloy Rod cover White anodized Aluminum alloy Head cover White anodized Enlarged view of A Aluminum alloy Cylinder tube Hard anodized Aluminum alloy Piston Chromated Hard chromate plated r Carbon steel Cushion spear A t Carbon steel Hard chromate plated Cushion spear B y Carbon steel Hard chromate plated Piston Rod
and Japanese NPT1/4 (M5 female threaded) N02 Option 1 G1/4 (M5 female threaded) Rc1/8 URJ1/4 TSJ1/4 Note) Fixed unit ISE80H: MPa Others : MPa, kPa With unit display switching function Fixed SI unit Note) F02 Nil C01 A2 B2 M P Initial value psi Option 2 Bottom ported R1/4 (M5 female threaded) None Nil 02L With bracket NPT1/4 (M5 female threaded) N02L A C01L A2L B2L Rc1/8 ZS-24-A ZS-35-A URJ1
b c d e f g Nil Reed switch L R Solid state switch S h Nil L R S Operating direction Left Right a b h g d c f e Note) Lead wire length symbols 0.5m .
3 EA EA y A A P P r q B EB B !4 EB !7 !1 !2 t Component Parts Aluminum alloy NBR Note No. !0 Description Material No. PBT ADC Material Note q Description Black zinc chromated Metallic plated Pilot body Body Piston guide B Valve Metallic plated !1 !2 w e Return spring Cushion Cushion Valve spring Return spring Piston B Head cover r Stainless steel Spool/sleeve Stainless steel ZDC !
Construction/Parts/Dimensions AN05/10/20 AN15/30/40 No hexagonal part in AN05 and AN10 B Dimensions (mm) B Port size R, NPT A B D Model Sound absorbing material (Resin sintered body) AN05-M5 AN10-01 AN15-02 AN20-02 AN30-03 AN40-04 6.5 15 M5 x 0.8 Body (Resin) A 23 1/8 11 A 32 1/4 14 16 Hexagonal flats D 14 45 1/4 16.5 17 58.5 3/8 20 Port size 21 68 24 1/2 2
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. Note 3) With a low number of operating cycles, even a valve with a small Cv factor can be operated.
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. Note 3) With a low number of operating cycles, even a valve with a small Cv factor can be operated.
IS400-1 (1S-1) IS400-2 (1S-2) Model Port size B J A C D E F G H I , 1 4 1 2 1 1 AL800-12 to 14-1 AL900-20-1 431 (481) 437 (487) 3 x M5 x 0.8 x depth 6 3 x M5 x 0.8 x depth 6 230 230 ( ): With float switch 117 117 60 60 100 100 2 59 63 166 162 73 73 1046
M5 M5 M5 M5 1)When using SMCs fitting, etc. After tightening by hand, give it additional 1/6 turn with a wrench. (1/4 turn for miniature fittings.) In case that two gaskets are equipped such as universal elbow or universal tee, give it additional 1/2 turn with a wrench.
5 Port Solenoid Valve Body Ported/Single Unit Series SY3000/5000/7000/9000 How to Order 5 L SY 5 1 20 01 Series Bracket 3 SY3000 5 SY5000 Nil: Without bracket F1: With foot bracket A, B port size Thread piping 7 9 SY7000 SY9000 2 position single only Symbol Port size M5 x 0.8 SY3000 Applicable series M5 1 8 01 SY5000 1 4 SY7000 02 02 03 Type of actuation Coil specifications 1 4 Standard Nil