Standard stroke Bore size (mm) Standard stroke (mm) Piping port position 15, 32 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700 Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left a b c d e f g h Nil Note 1) Consult SMC if the
(Refer to page 5 for detailed specifications of the contact protection boxes.) 6.2 5.7 3.4 12.5 Most sensitive position 11 Series CYP Clean Room Rodless Cylinder Solid State Auto Switches/Direct Mount Type D-Y59 /D-Y69 /D-Y7P (V) A B A B Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.
(Refer to page 5 for detailed specifications of the contact protection boxes.) 6.2 5.7 3.4 12.5 Most sensitive position 11 Series CYP Clean Room Rodless Cylinder Solid State Auto Switches/Direct Mount Type D-Y59 /D-Y69 /D-Y7P (V) A B A B Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: 11 LPM , 11 LPM, Max Pressure: 11.6 PSIG / 800 mbar , 11.6 PSIG / 800 mbar, Max Vacuum: 21.6 in HgV / -730 mbar , 21.6 in HgV / -730 mbar, Voltage (DC): 24, DC Motor Type: Standard, Item Dimensions: Length: 5.91 in / 150 mm Width: 3.43 in / 87 mm Height: 2.44 in / 62 mm , Length: 5.91
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: 11 LPM , 11 LPM, Max Pressure: 11.6 PSIG / 800 mbar , 11.6 PSIG / 800 mbar, Max Vacuum: 21.6 in HgV / -730 mbar , 21.6 in HgV / -730 mbar, Voltage (DC): 12, DC Motor Type: Standard, Item Dimensions: Length: 5.91 in / 150 mm Width: 3.43 in / 87 mm Height: 2.44 in / 62 mm , Length: 5.91
Thomas Rotary Vane Pump Max Flow: 8.5 LPM , 8.5 LPM, Max Intermittent Pressure: 450 mbar , 450 mbar, Max Continuous Pressure: 150 mbar , 150 mbar, Max Intermittent Vacuum: 50% , 50%, Max Continuous Vacuum: 15% , 15%, Motor Type: Brushless DC , Brushless DC, Nominal Voltage: 12 V DC , 12 V DC, Min.
Description Description Note AWG30 AW30P-340AS AF30P-060S AR30P-150AS C3SFP-260S C3SF (2) AWG40 AW40P-340AS AF40P-060S AR40P-150AS C4SFP-260S C4SF (2) 4 5 6 7 8 9 10 11 Valve assembly Filter element Diaphragm assembly Bowl O-ring Bowl assembly (1) 1 2 3 Body Bonnet Handle Brass, HNBR Platinum silver Black Black Non-woven fabric Weatherability NBR NBR PC PC Stainless steel Pressure gauge
Refer to VCW for model numbers and characteristics. 17-2-11 6 Series VCA Construction q w e r t Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Component Parts No.
Dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size B D E F H K L M N A C Model Note) Q V R Q R Q R S Q R S U 22 23 45 44 43 58 40.5 46.5 99 43 66 83 13.5 28 31 56.5 12.5 28 14 12.8 M4 4.5 64 1/8 VCL21 22 23 46 44 44 58 41.5 46.5 99 44 66 86 18 36 31 58.5 12.5 28 18 12.8 M4 6 67.5 1/4 24 25 56.5 46 54.5 60 52 48.5 101 54.5 68 99 22 40 36.5 11 15 32 20 19
(mm) Electrical entry P Port size B C D E F H K L M N A Grommet: G Conduit: C Conduit terminat: T Model Q R Q R Q R S U 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 22 59 44 50 99 50 66 83 1/8 VCS21 18 36 67.5 31 8.5 12.5 28 18 12.8 M4 6 22 62 44 53 99 53 66 86 1/4 22 40 81.5 36.5 11 15 32 20 19 M5 8 24 76 46 66.5 101 66.5 68 99 1/4, 3/8 VCS31 30 50 86 36.5 13.5 15 32 25 23 M5 8 24 80 46 71 101
An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 11 Series VCA 2 Port Solenoid Valve for Fluid Control Precautions 1 Be sure to read before handling. Design Selection Caution 1.
Description Material 0 3.5 7.1 10.6 14.1 17.7 21.2 24.7 NARM1000 NARM2000 134819 13615 13614 16.5 x 13.5 x 1.5 P7 Flow (SCFM) 7 8 9 10 11 13626 13625 13624 23 x 20 x 1.5 P8 Valve Valve spring Brass/NBR Stainless steel POM NBR NBR Pressure Characteristics Valve retainer O-ring O-ring Initial setting Supply pressure: 0.7MPa{7.1kgf/cm2} Secondary pressure: 0.2MPa{2.0kgf/c Flow: .4 SCFM NARM1000
Panel When mounting on a panel, refer to page 561 in Specific Product Precautions. 4.5 M5 x P0.5 8.5 M6 x P0.5 5.5 71 11 18 124 46 53 92 10 10 9.5 Bleed Bleed 63 Exhaust SUP(1) OUT(2) 30 OUT(2) SUP(1) 43 35 2 x Rc 1/8 Port size EXH 43 50 50 2 x Rc 1/4 Port size 2 x Rc 1/8 35 60 2 x Rc 1/8 Pressure gauge port Pressure gauge port 50 Mounting hole IR300-0 IR2120-02 36 2 Bracket (Option) 30
Note 11) For options: E1, E2, E3, E4. This product is for overseas use only according to the new Measurement Law. (The SI unit is provided for use in Japan.) Note 12) : For thread type: NPT only Note 13) : Combination available for options: E1, E2, E3, E4. Note 5) When choosing with H (panel mount), the installation space for lead wires will not be secured.
Note 11) For options: E1, E2, E3, E4. This product is for overseas use only according to the new Measurement Law. (The SI unit is provided for use in Japan.) Note 12) : For thread type: NPT only Note 13) : Combination available for options: E1, E2, E3, E4. Note 5) When choosing with H (panel mount), the installation space for lead wires will not be secured.
The adsorption column is cut right and left and alternately every about 150 seconds and changes. Please confirm the change is regularly divided by the flow of the reproduction air. It can know the outlet air atmospheric pressure dew point of Heatless Air Dryer because of the change in the color of upper Indicator.
The graphs below show the variation of the distance for the product to turn ON, for 3 types of gap, by changing the supply pressure (50 kPa) when the product is set to turn ON at 150 kPa supply pressure. Detection nozzle: 1.5 Piping: F type: 4 x 2.5 tube Test conditions G, H type: 6 x 4 tube Reference pressure: 150 kPa : Use within the rated pressure range (100 kPa to 200 kPa).
Seal material PTFE (FKM) Ambient temperature 20 to 100C (-4 to 212F) 184C (363F) or less (PTFE), 120C (248F) or less (FKM) Note 1) Fluid temperature Enclosure Dust proof, Splash proof (equivalent to IP65) Environment Location without corrosive or explosive gases Valve leakage cm/ min 300 (PTFE), 0.1 (FKM) with air Mounting orientation Unrestricted Vibration/Impact resistance m/s Note 2) 30/150
200 10 50 100 150 200 250 15 600 500 400 300 200 100 20 200 400 600 800 1000 25 200 400 600 800 1000 1200 1400 Flow rate Q [kg/h] ( ): Saturated steam holding heat (kcal/kg) ( ): Saturation temperature (C) For Water How to read the graph The pressure differential to generate a flow rate of 25 L/min water is as follows.
size 01 B 1 8 B 1 4 B 3 8 04 B 1 2 06 B AFF 1 Standard 11 2 Standard Nil Rc Thread type 02 03 JIS Symbol AME AM F G N NPT P . 14-20-57 3 4 1B Misc. 10 14 1 B 1 2 20 2B Caution Note) Refer to How to Order Bowl Assembly on page 14-20-59.