actuation VFN VZ314--01 (Piping: 6 x 1 m) Speed controller/Silencer AS3301F-02-06/AN110-01 Bore size Series CA1 Pressure 0.5 MPa Load factor 50% Stroke 400 mm Average speed (mm/s) Series 100 40 50 63 80 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ314--01 (Piping: 6 x 1 m) Speed controller/Silencer AS3301F-02-06/AN110-01 800 700 600 500 400 300 200
, IRV20: With GZ43-K-01) G ZN ZP ZA ZB Note 3) With ZSE30A-01-N-ML With ZSE30A-01-P-ML With ZSE30A-01-A-ML With ZSE30A-01-B-ML NPN open collector 1 output PNP open collector 1 output NPN open collector 2 outputs PNP open collector 2 outputs With digital pressure switch Fittings Nil L Straight Elbow Note 1) Two plug nuts are mounted on the gauge port.
I.D. 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFH04-01 KFH04-02 KFH06-01 KFH06-02 KFH06-03 KFH08U-01 KFH08U-02 KFH08U-03 KFH08N-01 KFH08N-02 KFH08N-03 KFH10U-02 KFH10U-03 KFH10U-04 KFH10N-02 KFH10N-03 KFH10N-04 KFH12U-02 KFH12U-03 KFH12U-04 KFH12N-02 KFH12N-03 KFH12N-04 10 10 15.5 1.5 1.6 13 23 14 25 36 16 25 37 16 24 36 32 40 65 31 39 64
Connection L2 M d A Effective area (mm2) Weight (g) L1 thread R Model 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFH04-01 KFH04-02 KFH06-01 KFH06-02 KFH06-03 KFH08U-01 KFH08U-02 KFH08U-03 KFH08N-01 KFH08N-02 KFH08N-03 KFH10U-02 KFH10U-03 KFH10U-04 KFH10N-02 KFH10N-03 KFH10N-04 KFH12U-02 KFH12U-03 KFH12U-04 KFH12N-02 KFH12N-03 KFH12N-04 10 10
-06 AS121FG-U10/32-07 18.3 23.1 11.7 13.5 18.1 22.9 11.6 12 6 1/4" 13.5 AS221FG-01-04 AS221FG-N01-01 12.7 20.4 27.5 9.3 4 1/8" 16 20.4 27.5 17 9.3 12.7 AS221FG-01-06 AS221FG-N01-03 14.3 13.5 20.4 27.5 11.6 6 5/32" 14.2 31.1 36.1 12 32.1 27.1 NPT 1/8 R 1/8 17 AS221FG-01-08 AS221FG-N01-05 12.7 14.3 23.1 30.2 19 18.5 25.3 32.4 15.2 11.4 36.1 8 3/16" 31.1 32.1 27.1 16.5 14.2 AS221FG-01-10 AS221FG-N01
[Option] Note) CE-compliant: For DIN terminal only VV3K3-S42-05-01 VV3K3-20-04 Common SUP/Common EXH Type 20: Body ported (A port top ported) How to Order Applicable solenoid valve VK332--M5(-Q) VK332--01(-Q) Applicable blanking plate assembly VK300-42-1A Bracket VK300-43-1A VV3K3 05 20 A port: Rc 1/8, M5 x 0.8 Valve stations Option P, R port thread type 01 1 station Nil None Nil F With
Type: 000 (Lever Type Feedback), Pressure Gauge: 2 (0.3MPa), Construction: 1 (w/Terminal Box)
Type: 100 (Rotary Type), Pressure Gauge: 2 (0.3MPa), Construction: 1 (w/Terminal Box)
Port Size: 0 (ZM Ejector Mounting), Switch & Voltage: 21 (Reed Switch/100VAC)
Body Size: 32, Pilot Type: 0 (Air Operated), Port: 02 (1/4), Thread: Rc, Voltage: None, Electrical Entry: None, Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style or None
Body Size: 22, Pilot Type: 0 (Air Operated), Port: 02 (1/4), Thread: Rc, Voltage: None, Electrical Entry: None, Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style or None
Function: 2 Position Double, Body Option: Class 2, Piping: Side, Port Size: 1/4, Voltage: 100VAC 50/60HZ, Electrical Entry: -, Thread: -, Option: -
Function: 2 Position Single, Body Option: Class 2, Piping: Side, Port Size: 1/4, Voltage: 100VAC 50/60HZ, Electrical Entry: -, Thread: -, Option: -
Function: 2 Position Single, Body Option: Class 3, Piping: Side, Port Size: 1/4, Voltage: 100VAC 50/60HZ, Electrical Entry: -, Thread: -, Option: -
Function: 3 Position Exhaust Center, Body Option: Class 3, Piping: Side, Port Size: 1/4, Voltage: 100VAC 50/60HZ, Electrical Entry: -, Thread: -, Option: -
Body Option: 3/8 Basis, Port Size: 1/4, Voltage: 100VAC 50/60HZ, Lead Wire: -, Option: -, Thread: -
Body Size: 32, Pilot Type: Air Operated, Port: 1/4, Thread: Rc, Voltage: None, Electrical Entry: None, Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style or None, Option: -
Type: Lever Type Feedback, Pressure Gauge: 0.3MPa, Construction: w/Terminal Box, Accessories: -, Connection: -
Type: Rotary Type, Pressure Gauge: 0.3MPa, Construction: w/Terminal Box, Accessories: -, Connection: -
Port Size: ZM Ejector Mounting, Switch & Voltage: Reed Switch/100VAC, Lead Wire Length: -