Air catch sensor, Operating pressure: 0.05 to 0.2MPa, Enclosure IP66, Port size: 1/8, Fluid: dry air, DIGITAL GAP CHECKER, AIR CATCH SENSOR, ISA ISA2 ISA3, 825, 121 lb
Air catch sensor, Operating pressure: 0.05 to 0.2MPa, Enclosure IP66, Port size: 1/8, Fluid: dry air, Digital Gap Checker, AIR CATCH SENSOR, ISA ISA2 ISA3, 827, 121 lb
Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 3000 SERIES 5 PORT VALVE, 4/5 PORT SOLENOID VALVE, VVD, 121
It should be applied for filtration of compressed air requiring high cleanliness for coating, ELEMENT ASSEMBLY, SUPER MIST SEPARATOR, 121, 180 lb
for filtration of compressed air requiring high cleanliness for coating lines, compressed air for clean rooms and compressed air for equipment necessary to avoid oils.Super mist separator, Modular connection is possible , Filter replacement time can be judged visually , Port size: 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1 1/2, 2 , Threads: Rc, G, NPT, SUPER MIST SEPARATOR, SUPER MIST SEPARATOR, 121
Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 3000 SERIES 5 PORT VALVE, 4/5 PORT SOLENOID VALVE, VVD, 121
0.7MPa (high pressure type 1.0MPa), Effective area mm 2 (Cv): metal seal 2.2 (0.12) - 16.2 (0.9); rubber seal 3.6 (0.2) - 21.6 (1.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50° C, 3000 SERIES 5 PORT VALVE, 4/5 PORT SOLENOID VALVE, VVD, 121
for filtration of compressed air requiring high cleanliness for coating lines, compressed air for clean rooms and compressed air for equipment necessary to avoid oils.Super mist separator, Modular connection is possible , Filter replacement time can be judged visually , Port size: 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1 1/2, 2 , Threads: Rc, G, NPT, SUPER MIST SEPARATOR, SUPER MIST SEPARATOR, 121
Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 3000 SERIES 5 PORT VALVE, 4/5 PORT SOLENOID VALVE, VVD, 121
Single acting, spring return, pin cylinder, Compact design-minimizes mounting space, Three bore sizes available, Strokes from 5mm to 15mm available, Two mounting styles available, Pin Cylinder, Double Acting, Sgl Rod, ROUND BODY CYLINDER, 371, 121 lb
3000 SERIES 5 PORT VALVE, 4/5 PORT SOLENOID VALVE, VVD, 121 lb
3000 SERIES 5 PORT VALVE, 4/5 PORT SOLENOID VALVE, VVD, 121 lb
internally (except size 10) to further improve reliability.Rotary actuator, free-mounting type, CRBU2, Sizes: 10, 15, 20, 30, 40, Possible direct mounting from 3 directions, Three styles of units available: switch, angle adjusting, switch and angle adjusting, Available in single or double vane, Single vane type can rotate up to 270°, Actuator, Free Mount Rotary, ROTARY ACTUATOR, 517, 121
The specification of the terminating resistor is 121 1%, 1/4 W. Figure 2 (3)How to connect. Tighten the connector fixing screws (M2.5 slotted head screws) firmly with a tightening torque of 0.2 to 0.3 Nm. Figure 3 -10No.EX-OMO0004-D 2. Wiring of the power supply Connect the power supply to the power supply connector (1 pc.).
Applied part GR-S-010 (10 g) GR-S-020 (20 g) GR-L-005 (5 g) GR-L-010 (10 g) Guide Cylinder 121
Fine particles are generated due to wear of emitters and motor sliding during operation. 26 IZF10/IZF10R Series Dimensions 96 82 80 79 39 37 110 121 96.5 94 103 Holding bolt Bracket 60.3 6.5 46 1 Power supply switch LED indicators Balance adjustment trimmer IZF10R 98.9 Air flow adjustment switch 64.1 Without bracket (39) 30 3 x 5.5 through 33.5 1.5 4 23 25 24.5 (46) 50 12.5 66.8 5.5 5.5 30
Secure with bolts, anchor bolts, etc. 121 HRS100/150 Series Specific Product Precautions 3 Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 13 to 16 for Temperature Control Equipment Precautions. Mounting/Installation Caution Caution 3.
(including 4 M10 bolts) Note 10) Weight (dry state) kg Approx. 121 Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 10C or less. Note 2) Use fluid in condition below as the circulating fluid.
equipartions of circumference) Bracket Port size R, NPT, G Cylinder speed (mm/s) Dimensions Element Drain piping type Drain guide Drain cock Oil bowl B' C C Drain cock Drain guide (A) (B) Rc , NPT, G Mounting bracket Port size Model C B A Drain piping F G H J K L B' D E 6 6 1/4 female thread M3 x 0.5 1 4 2.3 15 12 20 50 73 AMC220 40 56 88 100 22 Depth 8 Body size A B C M3 x 0.5 71 88 101 101 121
ITVH N Bracket dimensions With auto drain Model Port size A M L K J H G F E D C B L 178 211 277 321 B 260 298 366 436 T 9 9 11 11 S 8 16 21 26 R 78 97 98 115 P 50 35 45 46.5 U (Body) V (Adapter) 1 4, 3 8 1 4, 3 8 AMR3000 AMR4000 AMR5000 AMR6000 144 166 188 230 182 215 281 325 21.5 18 16 18.5 37 37 42 42 3.2 3.2 4.5 4.5 32 40 48 56 28 37 37 44 51 61 66 81 101 121 131 161 10 10 45 70 260 302