SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-46-02-M5"

(a) Direct Mounting with four M5 screws Mounting screw (M5) 4pcs. (prepared by customer) (b) DIN rail mounting The figure on the right shows how to mount the DIN rail mounting brackets. Secure the DIN rail mounting bracket using the mounting screws (M5 x 8) 2 places on one side (4 places on both Mounting screw M5X8 sides).

x 0.8 M4 x 0.5 M10 x 1 34 132.5 46 50 27.3 47 15 3H9 3.5 M5 x 0.8 8 32 27 3H9 3.5 19 3H9 3.5 M10 x 1.5 15 M6 x 1 M5 x 0.5 M12 x 1.25 37 168.5 58.5 63.5 39 54 20.5 4H9 4.5 M6 x 1 10 43 36 4H9 4.5 24 4H9 4.5 M10 x 1.5 15 M6 x 1 M5 x 0.5 M12 x 1.25 40 184 63.5 69 36.4 57 23 4H9 4.5 M6 x 1 10 48 39 4H9 4.5 28 4H9 4.5 M12 x 1.75 18 M8 x 1.25 M6 x 0.75 M14 x 1.5 46 214.5 76 78 42.4 66 26.5 5H9

X 0.8 (Finger opening port) Auto switch mounting groove (4 locations) 4-M5 X 0.8 44 (Piston rod and rack screw) 5.5 H M5 X 0.8 18.2 (Finger closing port) 12.4 0.5 9 8 8.4 16.8 15 31 Width across 12.5 A flats 8 (4 locations) (46) 20 15 15 7 Closed 7 7 34 20 10 10 Open G 4-M4 X 0.7 through (Thread for mounting attachment) Model MHL2-10D MHL2-10D1 MHL2-10D2 J 80 108 146 A B C D E F G H 38 54

Right) MXZ25L(Pilot port location: Left) 2 x M5 x 0.8 (Pilot port) 2 x M5 x 0.8 (Pilot port) 22.2 + Stroke 22.2 + Stroke 9.5 2.5 9.5 (54.9) (54.9) 8 8 2.5 Auto switch Auto switch 10 MXZ Series Model Selection For Transfer (1) Load weight and overhang L1 and L2, should be within the average speed limit in the graphs. (2) For horizontal use, overhang L3 should not exceed the allowable range

M2 M3 m1 m2 m3 16 25 40 16 25 40 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 100 120 100 38 35 35 MY2HT 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.

Required screws are as follows: 2 x M5 (End plate: torque = 1.5 Nm) 2 x M5 (SI Unit : torque = 1.5 Nm) 4 x M (Valve manifold: refer to valve manifold catalogue) Fig. 7-1 Required screws All manifolds are mounted using 8 screws (except VQC4000 which uses 7 screws). 25 No.EX##-OMY0004 7.1.1. Valve manifold connection Connect the valve manifold with the 2 screws on the SI Unit.

Range (mm) No. of auto switches mounted Applicable auto switch Bore size (mm) 25 6 4 D-M5, D-M5W, D-M5T D-E7A, D-E80A Auto switch model 40 6 4 D-M5, M5W, M5T D-E7A, E80A 32 6 4 10 15 5 10 1 pc. 2 pcs.

Refer to p.0-39 to 0-46 for common precautions of auto switch.

plug) Air supply unit circuit diagram M5 x 0.8 Stroke end air supply port 2-M5 x 0.8 air supply port C 82 (air supply port D on reverse side, hexagon socket head plug) 52 36 8 44 SMC When equipped with air supply unit system 1, there are two supply ports, A and C.

T-brackets T-nuts Model LC1-1-L5 (Weight: 16.0g) Model LC1-1-L3 (Weight: 15.5g) M (Weight: 10.0g) M5 M3 17.5 17.5 17.5 7.5 18 12 11 Model M 20 7.5 7.5 21 LC1-1-N3 M3 x 0.5 29 30 LC1-1-N5 M5 x 0.8 Controller Connectors These are connectors 'all halfpitch type' used for CN1 (control input/output) and CN2 (general purpose input/output).

Product number Suitable screws Tightening torque Thread depth PF3A703H Equivalent to M4 1.5 Nm 10 7 PF3A706H Equivalent to M5 3 Nm 10 8 PF3A712H Equivalent to M6 5.2 Nm 10 9 Prepared by the user.

22.5 29 19 14 4.2 M5 X 0.8 M22 X 1.5 20 23.5 29.5 36 5 37.5 43.5 50 6 CJPB6SCJP6, #6 CJPB10SCJP10, #6 CJPB15SCJP15, #6 1.2-10

Stroke (mm) Pulling force Bore size (mm) 40, 50, 63 80, 100 Thread size 3 10 N M3 x 0.5 x 30l or more 3 24.5 N M5 x 0.8 x 40l or more Remove the bolt for normal operation. It can cause lock malfunction or faulty release. Rubber cap 2. Manual release lock type Push the M/O knob and turn it 90 counterclockwise.

35 Motor mounting position: Right side parallel Motor mounting position: Left side parallel 106 4 106 48 5 3H9 (+0.025 0 ) depth 35 3H9 (+0.025 0 ) depth 35 8 46 46 47 47 H G *1 When mounting the actuator using the body mounting reference plane, set the height of the opposite surface or pin to be 3 mm or more.

Wiring 46 8.4. Process data 46 8.5. LED indicators 47 8.6. Block diagram 48 -2No.EX##-OMU0020-A 9. End Plate EX245-EA2-1/2 49 9.1. Parts and description 49 9.2. Specifications 50 10. Accessories 51 10.1. Markers 51 10.2. Y Connector 52 10.3. Seal cap 54 10.4. Joint pack 56 11. Dimensions 57 11.1. The Input/Output Modules Manifold 57 12. Troubleshooting 58 12.1. EX245-SPN1/SPN2 58 12.2.

Hs 46 50 56 Approx. Ht 26 26 26 16 Series CLK1 Clamp Cylinder with Lock Auto Switch Specifications Lead wire colors inside [ ] are those prior to conformity with IEC standards.

Parameter Setting Hardware Configuration (EDS file) I/O Map SWEDEN (46) 8 603 12 00 Ekhagsvgen 2931, SE-141 71 Segeltorp, Sweden (7) Set the Ethernet port Refer to the SMC website (URL https://www.smcworld.com) to obtain more detailed information about these setting above.

Parameter Setting Hardware Configuration (GSDML file) I/O Map SWEDEN (46) 8 603 12 00 Ekhagsvgen 2931, SE-141 71 Segeltorp, Sweden Refer to the SMC website (URL https://www.smcworld.com) to obtain more detailed information about these setting above.

(46) 8 603 12 00 Ekhagsvgen 2931, SE-141 71 Segeltorp, Sweden SWITZERLAND (41) 052 396 31 31 Dorfstrasse 7, CH-8484, Weisslingen, Switzerland UNITED KINGDOM (44) 0845 121 5122 Vincent Avenue, Crownhill, Milton Keynes, Buckinghamshire MK8 0AN, United Kingdom URL https://www.smcworld.com Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81

) (2)2mm 2 D (3) 40 30mm 50mm ()60mm 0mm 16 *LEH 10mm 25 30mm 30mm 50mm DIN 60mm 17 - 4 4.1 Node Address/Data Rate 1 DeviceNet MSD LSD Data Rate *1 PGM DeviceNet *2 010 *3 PGM DeviceNet Node Address MSD LSD Data Rate Node Address Data Rate MSD LSD 0 125kbps 10) 1) 1 250kbps 0 0 0 2 500kbps 0 1 1 3 PGM *1 0 2 2 9 6 2 62 6 3 63 6 4 PGM *1 9 9 2 PGM 64-99 01h MAC ID 063 02