II Air Cylinder Drive Systems Total Stroke Time and Speed at the End Series SV Series SV1000 Applicable bore size: 20, 25, 32, 40 Applicable related components Total stroke time s Solenoid valve Tubing Speed controller Silencer 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 200 CM2 20 50% 70% 10% 30% 150 Stroke mm AS2201F -01-06 AS2200-01 70% 100 50 10% 30% 50% 0 200 CM2 25 150 Stroke mm AS2201F
PA07 . 17 4.6 Auto tuning modePr.PA08 . 18 4.7 Input signal automatic on selectionPD01 . 18 4.8 Parameter setting by MR Configurator2TM . 19 4.8.1 Parameter reading . 20 4.8.2 Parameter setting (Ex. Control mode change) . 20 5.
GFCI 5. 6. 7. 13 1 13 R 13-2 IDFA6E-20-R 5A 30mA 13-3 1) 2) 3) 9.5mm M5 1.25mm 2 L N 6.5mm M3 1.25mm 2 6-3 14-3 13 2 14 T 14 T T 14-2, 14-3 14-1 1. 2. 3. GFCI 4. 5. GFCI 6. 7. 8. 9.
Flow Rate Range: 501 (5 to 500 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: F (PNP; Analog 4 to 20 mA), Option 1: w/Lead Wire w/Connector, Unit Specifications: Unit Selection Function, Option 2: R (With Bracket), Calibration Certificate: A (With Calibration Certificate)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification: J (OUT 1: Analog 1 to 5V; OUT 2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F), Bracket: R (
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Body Needle V seal Lock nut Adjustment handle Insert bushing Nut Collar A 1 2 3 4 5 6 7 8 PFA PCTFE PTFE PVDF PVDF PFA PFA PFA Body class 2 y u y u B Dimensions A (B) (max.S) D H Port A 2 x G SMC (J) SMC C E F K Port B E A B C D E F G H J K S Model 48 60 72 LVN20 LVN30 LVN40 24 30 36 12 18 22 88 110 124 34.5 43 52 6 9 11 4 5 6 14 25 25 20 26 33 18 24 30 2.4 7.5 8.0 940 LQ1/LQ3/LVN/LQHB Series
Auto switches with load voltage less than 20 V cannot be used. Because there is no current leakage, the load voltage will not increase when turned OFF. However, depending on the number of auto switches in the ON state, the indicator lights may sometimes grow dim or not light up, due to the dispersion and reduction of the current flowing to the auto switches.
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: B (Out 1: PNP, Out 2: Flow Rate: PNP, Temp.: None, Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket
Note 2) On the AMC220,an R(PT)1/4 fitting can be attached by Note 1) Female thread: Available only AMC220, 320, 520 N NPT 04 1 2 F G(PF) 06 3 4 removing the drain cock. (It becomes the drain piping style) How to Order Oil Case Assembly If the oil case becomes damaged, it can be replaced easily.
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: N (w/o Lead Wire and M8 Connector)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: N (w/o Lead Wire and M8 Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: R (w/Bracket)
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F), Bracket: R (Bracket)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F), Bracket: R (Bracket)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only)
Flow Rate Range: 102 (10 to 1000 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: F (PNP; Analog 4 to 20 mA), Option 1: N (No Lead Wire), Unit Specifications: M (SI Unit Only), Option 2: R (With Bracket)