Size: 70, Voltage: 30 (Three-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ), Options: LR (L + R)
Size: 80, Voltage: 30 (Three-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ), Options: RT (R + T)
Size: 60, Voltage: 30 (Three-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ), Options: RT (R + T)
Size: 80, Voltage: 30 (Three-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ), Options: LT (L + T)
Size: 80, Voltage: 20 (Single-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ)
Size: 80, Voltage: 30 (Three-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ)
Size: 60, Voltage: 30 (Three-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ), Options: T (w/Terminal Block for Operating, Error and Remote Operation Signals)
Size: 60, Voltage: 30 (Three-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ)
Size: 60, Voltage: 20 (Single-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ), Options: A (Cool Compressed Air Output)
Size: 90, Voltage: 30 (Three-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ)
Body Size: 4000, Port Thread: N (NPT), Port Size: 04 (1/2), Option: None, Voltage: 3 [110 VAC (115 VAC)], Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Flow Direction, Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 2000, Port Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 3 [110 VAC (115 VAC)], Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Flow Direction, Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 3000, Port Thread: N (NPT), Port Size: 03 (3/8), Option: None, Voltage: 3 [110 VAC (115 VAC)], Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Flow Direction, Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Port Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 3 [110 VAC (115 VAC)], Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None or Manual Override, Flow Direction, Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Port Thread: N (NPT), Port Size: 06 (3/4), Option: G (Round Type Pressure Gauge w/Limit Indicator), Voltage: 3 [110 VAC (115 VAC)], Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None or Manual Override, Flow Direction, Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Port Thread: N (NPT), Port Size: 10 (1), Option: None, Voltage: 3 [110 VAC (115 VAC)], Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Flow Direction, Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+K
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: K (w/Fluid Fill Port)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC)