VN Rated voltage 1 2 3 4 5 6 7 8 9 Solenoid valve option Nil Standard 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-10 by Applicable Fluids Check List for special fluids outside of the standard.
200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400500 1000 1500 Piston speed mm/s Piston speed mm/s Piston speed mm/s Piston speed mm/s Features 6
100 2000 110.5 0 2500 138 1,000 2,000 3,000 3000 88.5 Maximum speed Vmax (mm/s) Note) Refer to page 1202 for the maximum absorbed energy since cushioning ability may in some cases exceed the allowable cushioning ability if the cylinder is used under high speeds and large loads. 100 250 =0.7 200 0.5 0.1 0.3 150 100 50 0 1,000 2,000 3,000 Maximum speed Vmax (mm/s) : Cylinder load ratio Vmax
100 90 100 Inner volume cm3 1 1.1 2.6 2.7 5.6 5.7 14.4 14.5 Double vane Be sure to read before handling.
70 to 100 Maximum pushing force LEP 10 (Basic) 100 50 to 100 LEP 10L (Compact) 100 60 to 100 Parameter protect 1: Common + StepData Changeable parameter 1: Common + StepData, 2: Common Enable switch 2: Disable Select 1:Enable or 2:Disable when using a teaching box Model name Part no. of each product Only the English characters and numbers are changeable.
201 to 350 Minimum stroke for mounting auto switches 25 301 to 400 32 301 to 450 Number of auto switches Model 40 301 to 800 25, 50, 75, 100, 125, 150, 200, 250, 300 2 pcs. 1 pc. 50, 63 301 to 1200 D-G5BA 15mm 10mm 80 301 to 1400 Refer to page 15 for details. 100 301 to 1500 Note 1) All non-standard strokes are produced upon receipt of order.
Table 8-1 Quality standard for fresh water (tap water) Item Product Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulfuric acid ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness
H4 S y m b o l Initial power / Power consumption (W) 100 VAC 200/40 200/50 400/100 600/150 200 VAC 800/40 800/50 1600/100 2400/150 Heater assembly number XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 XL1A25-60S-3 XL1A25-60S-2 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs.
H4 Initial power / 100 VAC 200/40 200/50 400/100 600/150 Power Symbol 200 VAC 800/40 800/50 1600/100 2400/150 consumption (W) Heater assembly number XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 XL1A25-60S-3 XL1A25-60S-2 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs.
H4 S y m b o l Initial power / Power 100 VAC 200/40 200/50 400/100 600/150 200 VAC 800/40 800/50 1600/100 2400/150 consumption (W) Heater assembly number XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 XL1A25-60S-3 XL1A25-60S-2 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs.
Seal Metal seal Rubber seal Coil voltage 0 1 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Function 1 2 3 Stations U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) D side (2) Note 1) Applicable to DC specifications. Note 2) Refer to page 2-5-39 for external pilot specification.
H4 Initial power / 100 VAC 200/40 200/50 400/100 600/150 Power Symbol 200 VAC 800/40 800/50 1600/100 2400/150 consumption (W) Heater assembly number XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 XL1A25-60S-3 XL1A25-60S-2 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs.
30 10 334 150 40 13 13 16 16 19 19 22 22 32 100 63 113 76 119 76 145 90 151 90 166 106 173 106 200 122 253 160 8 12 6 40 66 84 28 5 2.0 27 37 1/4,3/8 172 AMH250 178 1/2 8 12 6 40 66 84 28 5 2.0 27 37 3/8, 1/2 204 AMH350 3/4 210 8 14 7 50 80 100 34 5 2.3 32 37 8 14 7 50 80 100 34 5 2.3 32 37 10 14 9 55 88 110 50 9 3.2 37 37 10 14 9 55 88 110 50 9 3.2 37 37 10 16 9 65 102 130 60 10 4.5 39
Gasket INLET OUTLET 277 ZFA Series Dimensions: ZFA 100 200 Single unit Bracket Cover opened-up dimensions 70 Element extracted dimensions 55 2 x 4.5 2 x Port size Note) The above diagram is for ZFA200. The bracket location shows L side.
Err42 Err8 No.1ON ON ON LEDNo.10 Err9 3 P3 2 P2 Err9 Err9 ON ON ON ()5mm Err5 5mm 1 1 Err10 Err11 CPU Err12 ON 8P8 48 11-2 () 200 200 6P6 *L=1mm *200.0 1 PRG STEP P6 200 200 300mm/sec 50% 35% 49 12. 121 No. P1 No.
Grommet Class B coil: AWG20 Outside insulator diameter of 1.8 mm 2 port q w Lead wire color Rated voltage w Red Blue Red Gray q Black Blue Red Gray DC 100 VAC 200 VAC Other AC Maintenance Warning There is no polarity. 1. Removing the product The valve will reach a high temperature when used with high temperature fluids.
Cylinder Speed Chart Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series Average speed (mm/s) 800 700 600 500 400 300 200 100 0 It is when the cylinder is extending that is meter-out controlled by speed controller which
14000 22000 36000 55000 0.5 0.5 0.5 0.5 0.5 0.5 0.75 1 1.25 2 2.5 3 Basic type, Flange type, Foot type Mounting Operating range Center of sphere Operating range Axial center 5 Semi-standard/Thread nominal size -5 to 60C JA20-8-100 JA25-10-150 JA32-10-100 JA40-12-125 JA40-12-150 JA40-12-175 JA50-16-150 JA63-16-200 JA80-20-250 JA100-24-300 JA100-27-150 JA125-27-200 JA160-33-200 20 25 32 32
ISA2-G 1 ISA2-G 5 ISA2-H 1 ISA2-H 5 Detection zone 0.01 to 0.25 mm 0.03 to 0.50 mm Fluid Dry air (Filtered through a 5 m filter) Operating pressure range 30 to 200 kPa 50 to 200 kPa Detection nozzle size 1.5 2.0 50 kPa 5 or less 10 or less Supplied pressure Flow consumption L/min (ANR) 100 kPa 8 or less 15 or less 200 kPa 12 or less 22 or less Power supply voltage 12 to 24 VDC10%, ripple
Lateral load Operating pressure: 1 MPa 1000 200 300 500 Stroke Eccentric distance 100 100 Load weight (kg) 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 63 Allowable lateral load (N) 50 40 63 1 32 25 20 50 40 10 32 0.1 25 10 100 200 300 500 1000 Maximum piston