SMC Corporation of America
Elite Part Number Search
Search Results "MXP12-25C-M9PSAPC"

Note 2) Determined under the following conditions: water as the recirculating fluid, set temperature 77F (25C), facility water temperature 77F (25C), flow rate 0.8 gpm (3 L/min), ambient temperature 77F (25C), and sealed from outside air with a lid. Note 3) Differs depending on the operating conditions. Note 4) An appropriate range is from 0.8 to 1.3 gpm (3 to 5 L/min).

Tap Water (as a Circulating Fluid) Quality Standards The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulation type Make-up water Item Unit Standard value Influence Corrosion Scale generation Voltage pH (at 25C) 6.0 to 8.0 v v Electric conductivity (25C) [mS/cm] 100*1 to 300*1 v v Chloride ion (Cl) [mg/L] 50 or less v Sulfuric acid

Servo motor (24 VDC) 77F = 25C, 104F = 40C Ambient temperature: 25C or less Ambient temperature: 40C LEY16Am Pushing force [%] Duty ratio [%] Continuous pushing time [min.]

Basic conditions Supply dew point: 20C (Atmospheric pressure dew point) Supply pressure: 0.5 MPa Ambient environment: 25C, 40% Fig.1 Verification Chart of Condensation (a) Find the correction factors.

Approx.1200W(water), 800W(Fluorinert FC-77) Cooling capacity Conditions: set temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 10 L/min Approx.2200W(water), 1500W(Fluorinert FC-77) Heating capacity Conditions: set temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 10 L/min Recirculating fluid : Water, Fluorine solvent(GALDEN

3 to @4 are at room temperature (20 to 25C). Type of Impact Load Free fall impact Check Model Selection Step z to c prior to use. Graph !3/RJ06 Graph !5/RJ10 Graph !

) 3% F.S. or less (0 to 50C, based on 25C) Temperature characteristics Analog voltage output (non-linear) output impedance 1 k output for display unit PF2A3 Output for display unit Resistance Output Note 2) specifications Voltage output 1 to 5 V (within the flow rate range) Linearity: 5% F.S. or less; allowable load resistance: 100 k or more.

For details, refer to the optional accessory (page 11). 6 HEF Series Cooling Capacity Circulating fluid: Water, Flow rate: 1 L/min Circulating fluid: Water, Flow rate: 1 L/min, When constant fan speed mode is selected 600 600 500 500 Cooling capacity [W] Cooling capacity [W] Ambient temperature 25C 400 400 Ambient temperature 25C 300 300 200 200 Ambient temperature 35C Ambient temperature

MHZ2-25C/MHZL2-25C MHZ2-6C/MHZA2-6C 140 Pressure 0.7 MPa Pressure 0.7 MPa 8 120 0.6 MPa 0.6 MPa Pressure 0.7 MPa Pressure 0.7 MPa Gripping force (N) Gripping force (N) 100 6 0.5 MPa 0.5 MPa 0.6 MPa 0.6 MPa 80 0.4 MPa 0.4 MPa 0.5 MPa 0.5 MPa F 4 60 0.3 MPa 0.3 MPa 40 0.4 MPa 0.4 MPa 2 0.25 MPa 0.25 MPa 20 0.3 MPa 0.3 MPa 0 10 20 30 0 20 40 60 80 100120 Gripping point L (mm) Gripping point

MHZ2-25C/MHZL2-25C MHZ2-6C/MHZA2-6C 140 Pressure 0.7 MPa Pressure 0.7 MPa 8 120 0.6 MPa 0.6 MPa Pressure 0.7 MPa Pressure 0.7 MPa Gripping force (N) Gripping force (N) 100 6 0.5 MPa 0.5 MPa 0.6 MPa 0.6 MPa 80 0.4 MPa 0.4 MPa 0.5 MPa 0.5 MPa F 4 60 0.3 MPa 0.3 MPa 40 0.4 MPa 0.4 MPa 2 0.25 MPa 0.25 MPa 20 0.3 MPa 0.3 MPa 0 10 20 30 0 20 40 60 80 100120 Gripping point L (mm) Gripping point

MHZ2-25C/MHZL2-25C MHZ2-6C/MHZA2-6C 140 Pressure 0.7 MPa 8 120 0.6 MPa Pressure 0.7 MPa Gripping force (N) Gripping force (N) 100 6 0.5 MPa F 0.6 MPa 80 0.4 MPa 0.5 MPa 4 60 0.3 MPa 40 0.4 MPa 2 0.25 MPa 20 0.3 MPa F 0 10 20 30 0 20 40 60 80 100 120 Gripping point L (mm) Gripping point L (mm) Internal Grip MHZ2-10C/MHZL2-10C MHZ2-32C MHZA2, MHZ2, MHZL2 250 Pressure 0.7 MPa Pressure 0.7 MPa

Note 2) Power supply 12 months continuous operation (without back lighting) Battery life 250ms Response speed 2% F.S. or less (Temperature conditions: at 25C) Display accuracy 1% F.S. or less (Temperature conditions: at 25C) Repeatability 3% F.S. or less (0 to 50C, based on 25C) Temperature characteristics M5 x 0.8 Piping port 0 to 50C (with no condensation) Ambient temperature 35 to 85%

(Based on 25C) Enclosure Operating temperature range Operating humidity range Withstand voltage Temperature characteristics Note 1) When analog voltage output is selected, analog current output cannot be used together. Note 2) When analog current output is selected, analog voltage output cannot be used together.

(not including sensor accuracy), Response time: 150 ms or less Accuracy (to display value) (25C) 1.0% F.S. or less 1.5% F.S. or less 2.0% F.S. or less 0.5% F.S.

(10 to 60C: based on 25C) 2% F.S. or less (25C) 3% F.S. or less (25C) Temperature characteristics 0.2% F.S. or less 1% F.S. or less Repeatability 0.3% F.S. or less Hysteresis Output Display (Resolution) IP40 IP65 IP40 Enclosure Note Page 16-3-1 16-3-33 16-3-23 16-1-2 2 Electronic Pressure Switch Series (Separate Type) Model Selection Table Controller PSE300 PSE200 Model Sensor input amount

(Not including sensor accuracy), Response time: 150 ms or less Accuracy (To display value) (25C) 1.0% F .S. or less 1.5% F .S. or less 2.0% F .S. or less PF2 0.5% F .S.

) 3% F.S. or less (10 to 60C: based on 25C) 2% F.S. or less (25C) 3% F.S. or less (25C) Temperature characteristics 0.2% F.S. or less 1% F.S. or less Repeatability 0.3% F.S. or less Hysteresis Output Display (Resolution) IP40 IP65 IP40 Enclosure Note Page 16-3-1 16-3-33 16-3-23 17-5-176 36 Electronic Pressure Switch Series (Separate Type) Model Selection Table Controller PSE300 PSE200 Model

(at 25C water) Repeatability 1% F.S.

Trace the arrow mark, starting from F for cooling temperature 25C (pressure dew point 25C) to obtain the intersection G on the pressure characteristic line for 0.7 MPa. 8. From the intersection G, trace the arrow mark to obtain the intersection H on the vertical axis. 9.

object m (kg) Mass of transferred object m (kg) Mass of transferred object m (kg) 20 30 30 Example 2 RS 20 20 10 MI 10 10 5 4 3 4 5 3 4 5 3 2 2 2 1 1 1 1 5 10 20 10 5 1 20 30 10 5 1 20 30 Transfer speed (m/min) Transfer speed (m/min) Transfer speed (m/min) Lever-type mass of transferred object and transfer speed graphs (graphs (2) and (3)) show the values at room temperature (20 to 25C