MHZ2-25C/MHZL2-25C MHZ2-6C/MHZA2-6C 140 Pressure 0.7 MPa 8 120 0.6 MPa Pressure 0.7 MPa Gripping force (N) Gripping force (N) 100 6 0.5 MPa F 0.6 MPa 80 0.4 MPa 0.5 MPa 4 60 0.3 MPa 40 0.4 MPa 2 0.25 MPa 20 0.3 MPa F 0 10 20 30 0 20 40 60 80 100 120 Gripping point L (mm) Gripping point L (mm) Internal Grip MHZ2-10C/MHZL2-10C MHZ2-32C MHZA2, MHZ2, MHZL2 250 Pressure 0.7 MPa Pressure 0.7 MPa

Note 2) Power supply 12 months continuous operation (without back lighting) Battery life 250ms Response speed 2% F.S. or less (Temperature conditions: at 25C) Display accuracy 1% F.S. or less (Temperature conditions: at 25C) Repeatability 3% F.S. or less (0 to 50C, based on 25C) Temperature characteristics M5 x 0.8 Piping port 0 to 50C (with no condensation) Ambient temperature 35 to 85%

(Based on 25C) Enclosure Operating temperature range Operating humidity range Withstand voltage Temperature characteristics Note 1) When analog voltage output is selected, analog current output cannot be used together. Note 2) When analog current output is selected, analog voltage output cannot be used together.

(not including sensor accuracy), Response time: 150 ms or less Accuracy (to display value) (25C) 1.0% F.S. or less 1.5% F.S. or less 2.0% F.S. or less 0.5% F.S.

(10 to 60C: based on 25C) 2% F.S. or less (25C) 3% F.S. or less (25C) Temperature characteristics 0.2% F.S. or less 1% F.S. or less Repeatability 0.3% F.S. or less Hysteresis Output Display (Resolution) IP40 IP65 IP40 Enclosure Note Page 16-3-1 16-3-33 16-3-23 16-1-2 2 Electronic Pressure Switch Series (Separate Type) Model Selection Table Controller PSE300 PSE200 Model Sensor input amount

(Not including sensor accuracy), Response time: 150 ms or less Accuracy (To display value) (25C) 1.0% F .S. or less 1.5% F .S. or less 2.0% F .S. or less PF2 0.5% F .S.

) 3% F.S. or less (10 to 60C: based on 25C) 2% F.S. or less (25C) 3% F.S. or less (25C) Temperature characteristics 0.2% F.S. or less 1% F.S. or less Repeatability 0.3% F.S. or less Hysteresis Output Display (Resolution) IP40 IP65 IP40 Enclosure Note Page 16-3-1 16-3-33 16-3-23 17-5-176 36 Electronic Pressure Switch Series (Separate Type) Model Selection Table Controller PSE300 PSE200 Model

(at 25C water) Repeatability 1% F.S.

Trace the arrow mark, starting from F for cooling temperature 25C (pressure dew point 25C) to obtain the intersection G on the pressure characteristic line for 0.7 MPa. 8. From the intersection G, trace the arrow mark to obtain the intersection H on the vertical axis. 9.

object m (kg) Mass of transferred object m (kg) Mass of transferred object m (kg) 20 30 30 Example 2 RS 20 20 10 MI 10 10 5 4 3 4 5 3 4 5 3 2 2 2 1 1 1 1 5 10 20 10 5 1 20 30 10 5 1 20 30 Transfer speed (m/min) Transfer speed (m/min) Transfer speed (m/min) Lever-type mass of transferred object and transfer speed graphs (graphs (2) and (3)) show the values at room temperature (20 to 25C

Viscosity: 3mPas (3cP) or less Detection style Karman vortex Rated flow range 0.4 to 4 l/min 1.8 to 20 l/min Note 1) 4 to 40 l/min Operating pressure range Note 2) 0 to 1 MPa 0 to 0.6 MPa Proof pressure Note 3) 1.5 MPa 0.9 MPa Operating fluid temperature 0 to 90C Linearity Note 4) 2.5% F.S. or less (at 25C water) Repeatability 1% F.S. or less (at 25C water) Temperature characteristics 5%

Item Unit Standard value Influence 10 s Corrosion Scale generation 5 s pH (at 25C) 6.0 to 8.0 v v Electric conductivity (25C) [S/cm] 100* to 300* v v Chloride ion (Cl) [mg/L] 50 or less v Sulfuric acid ion (SO42) [mg/L] 50 or less v 2 s Min. 1 s Standard item 0.5 s 0.2 s Acid consumption amount (at pH4.8) [mg/L] 50 or less v Total hardness [mg/L] 70 or less v Calcium hardness (CaCO3) [mg

Tap Water (as Facility Water) Quality Standards The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulation type Make-up water Influence Item Unit Standard value Corrosion Scale generation pH (at 25C) 6.0 to 8.0 v v Electric conductivity (25C) [S/cm] 100* to 300* v v Item Unit Standard value Influence Standard item Chloride ion (Cl)

Item Unit Standard value Influence Protection Circuit Corrosion Scale generation pH (at 25C) 6.5 to 8.2 v v Electric conductivity (25C) [S/cm] 100* to 800* v v Chloride ion (Cl) [mg/L] 200 or less v Sulfuric acid ion (SO42) [mg/L] 200 or less v Caution Standard item If operating in the below conditions, the protection circuit will activate and an operation may not be performed or will stop

Protection Circuit Item Unit Standard value Influence Corrosion Scale generation Caution pH (at 25C) 6.5 to 8.2 v v Electric conductivity (25C) [S/cm] 100* to 800* v v Chloride ion (Cl) [mg/L] 200 or less v Sulfuric acid ion (SO42) [mg/L] 200 or less v If operating in the below conditions, the protection circuit will activate and an operation may not be performed or will stop.

Trace the arrow mark, starting with F for cooling temperature 25C (pressure dew point 25C) to find the intersection G on the pressure characteristic line for 0.7 MPa. 8. From the intersection G, trace the arrow mark to obtain the intersection H on the vertical axis. 9. The intersection H is the amount of water included in the compressed air 1 m3 at 0.7 MPa, pressure dew point of 25C.

Item CH1 CH2 Setting range 5 to 35 10 to 40 CH2 set temperature CH1set By default 20 25 temperature [Tips] Sample set temperature: To change from CH1SP: 25C and CH2SP: 30C status, to CH2SP: 15C, first set CH1SP to 15C and then CH2SP to 15C. If CH2SP is set to 15C before setting CH1SP to 15C, then the following message appears: Please set CH1SP first.

minute between live parts and case Insulation resistance 50 M between live parts and case (at 500 VDC) 10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s2 acceleration, Vibration resistance in X, Y, Z directions, for 2 hours each (De-energized) 980 m/s2 in X, Y, Z directions, 3 times each (de-energized) Impact resistance Temperature characteristics 2% F.S. or less (based on 25C

Minimum display unit (Ambient temperature of 25C) Analog output accuracy 0.5% F.S. (Ambient temperature of 25C) Repeatability 0.1% F.S. Minimum display unit Temperature characteristics 0.5% F.S. (Ambient temperature: 0 to 50C, 25C standard) Accuracy Output type Select from NPN or PNP open collector output.

Temperature characteristics Ambient temperature 5% F.S. (25C reference) Fluid temperature 5% F.S. (25C reference) Operating pressure range*3 0 to 1 MPa Proof pressure*3 2 MPa Accumulated flow range*4 9.9 L 9 L by 0.1 L by 1 L Switch output NPN or PNP open collector output Maximum load current 80 mA Maximum applied voltage 28 VDC Internal voltage drop NPN: 1 V or less (at load current of 80