Bore sizes: 10, 15, 20, 25, 32, 40 mm; Stroke lengths: 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke lengths: 500 mm (10 bore), 1000 mm (15 bore), 1500 mm (20 bore), 2000 mm (25, 32 & 40 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.
Bore sizes: 10, 15, 20, 25, 32, 40 mm; Stroke lengths: 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke lengths: 500 mm (10 bore), 750 mm (15 bore), 1000 mm (20 bore), 1500 mm (25, 32 & 40 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.
Bore sizes: 10, 15, 20, 25, 32, 40 mm; Stroke lengths: 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke lengths: 500 mm (10 bore), 750 mm (15 bore), 1000 mm (20 bore), 1500 mm (25, 32 & 40 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec
Bore sizes: 10, 15, 20, 25, 32 mm; Stroke lengths: 150, 200, 300, 400, 500, 600, 800, 1000 mm; Maximum stroke lengths: 500 mm (10 bore), 750 mm (15 bore), 1000 mm (20 bore), 1200 mm (25 bore), 1500 mm (32 bore); Minimum operating pressure: 0.2 MPa (29 psi); Speed: 70 ~ 300 mm/sec.
Bore sizes: 25, 32 40, 50, 63 mm; Stroke lengths: 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke length: 1300 mm (25, 32, 40, 50 & 63 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.
Bore sizes: 25, 32 40, 50, 63 mm; Stroke lengths: 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke length: 1300 mm (25, 32, 40, 50 & 63 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.
Pressure sensor for general purpose fluids, Fluid: fluid, including gas, that will not corrode SUS316L, Accuracy (ambient temp. of 25C): 1%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP65, SENSOR, GENERAL FLUID SWITCH, INSTRUMENTATION, PSE200/300/530-560, DX, PSE200/300/530-560 1/4, .80129 lb
Compact pressure sensor for pneumatics, Proof pressure: 500kPa, Accuracy (ambient temp. of 25C): 2%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP40, SENSOR, MINIATURE AIR, VACUUM, INSTRUMENTATION, PSE200/300/530-560, CB, PSE200/300/530-560 1/8 NPT, .17553 lb
2% F.S.or less, allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)20 mA or less (without load)IP65Operating: 0 to 50C, Stored: ?
Pressure sensor controller, Response time: 1 ms or less, Set pressure resolution: 1/1000, Repeatability: 0.1% F.S. or less, Enclosure: IP40, CONTROLLER, REMOTE DISPLAY, INSTRUMENTATION, PSE200/300/530-560, 1X, PSE200/300/530-560 OTHER SIZE, .37654 lb
0.1% F.S. or less, Enclosure: IP40, CONTROLLER, REMOTE DISPLAY, INSTRUMENTATION, PSE200/300/530-560, 1X, PSE200/300/530-560 OTHER SIZE, .40280 lb
Multi channel controller, Low power consumption: 55mA or less, NPN or PNP open collector available, Simplified application, Space saving, CONTROLLER, PRESSURE SENSOR, INSTRUMENTATION, PSE200/300/530-560, 1X, PSE200/300/530-560 OTHER SIZE, .36960 lb
Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size *: 125, 140, 160, 180, 200, Standard stroke *: 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable, Compact Cylinder, CQ2-Z, COMPACT CYLINDER, 493, 300 lb
Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size *: 125, 140, 160, 180, 200, Standard stroke *: 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable, Compact Cylinder, CQ2-Z, COMPACT CYLINDER, 493, 300 lb
. *3 Temperature characteristics (25 oC reference) 2%F.S. max. (15 to 35 oC) 5%F.S. max. (0 to 50 oC) Pressure characteristic (0 kPa reference 4) 2%F.S. max. (0 to 300 kPa) 5%F.S. max. (-70 to 0 kPa) Rated pressure range -70 kPa to 300 kPa Operating pressure range -100 kPa to 400 kPa Proof pressure 500 kPa (Non-linear output) 5 Output voltage 1 to 5 V Analogue output Response time 5 ms or
(page 72) Y S16 0x012C 3 R/W (300) P1H (Upper limit of the OUT1 window comparator) Setting of OUT1 upper limit of window comparator. (page 72) 0x04C4 (1220) 0x04C5 (1221) 0x04C6 (1222) 0x04C7 (1223) Y S16 0x0258 4 R/W (600) WH1 (Setting of OUT1 window comparator hysteresis) Setting of OUT1 window comparator hysteresis.
Max. 150 NL/min 3000 NL/min PF2A703H 5.5 CFM 106.0 CFM 300 NL/min 6000 NL/min PF2A706H 10.5 CFM 212.0 CFM 600 NL/min 12000 NL/min PF2A712H 21.0 CFM 423.5 CFM : Analogue output is based on the rated flow range at normal condition. Displayed flow range is based on standard condition. Therefore, the range of rated flow and the displayed flow are different..
Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 L/min L/min L/min L/min L/min Pressure Rated pressure range -50 kPa to 0.5 MPa -50 kPa to 0.75 MPa Proof pressure 1.0 MPa Output for PF2A3 Analogue voltage output (non-linear), Output impedance: 1 k Voltage output 1 to 5 V Output impedance 1 k Analogue output Current output 4 to 20 mA Load impedance Power supply voltage 12 V: 300
. -19No.PF-OMO0014-D Output for PF2W3 + Analogue (4 to 20 mA) type PF2W5--2Analogue output: 4 to 20 mA Load impedance: 300 (12 VDC) 600 (24 VDC) 1: Refer to the PF2W3 operation manual for details of the flow monitor. 3: Load indicates analogue input equipment such as an ammeter. -20No.PF-OMO0014-D Troubleshooting Troubleshooting If an operation failure occurs with the product, use the chart
Min. load impedance: 100 k (Output impedance: 1 k) Analogue output Current output: 4 to 20 mA, Accuracy: 2%F.S. or less Max. load impedance: 300 or less with 12 VDC, 600 or less with 24 VDC Supply voltage 12 to 24 VDC 10% Power consumption (No load) 20 mA or less Enclosure IP65 Environment Operating temperature range Operation: 0 to 50 C, Storage: -25 to 85 C (no condensation or freezing