Step Axis Movement mode Speed Position Acceleration Deceleration Pushing force Trigger LV Pushing speed Moving force Area 1 Area 2 In position Comments mm/s mm mm/s2 mm/s2 mm mm mm Axis 1 ABS 500 100.00 3000 3000 0 85.0 50 100.0 10.0 30.0 0.5 Axis 2 ABS 500 100.00 3000 3000 0 85.0 50 100.0 10.0 30.0 0.5 0 Axis 3 ABS 500 100.00 3000 3000 0 85.0 50 100.0 10.0 30.0 0.5 Axis 1 INC 500 200.00
Refer to page 714.) 25 or less 40 or less 5 3 Fluid 2 position single 2 position double 3 position Operating pressure range MPa Ambient and fluid temperature Response time ms (0.5 MPa) Max. operating frequency (Hz) Manual override (Manual operation) Pilot exhaust method Lubrication Mounting orientation Impact/Vibration resistance m/s2 Note 1) 2 position single, double 3 position 2 position
Move Speed Position Accel PushingF T riggerL V PushingSp Moving F Area1 Area2 In posn mm/s2 mm/s mm mm/s2 mm/s mm mm mm 0 Absolute 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 Absolute 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 Absolute 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 6.
The unit conversion between SI and conventional units are as follows: Oscillation acceleration 100m/s2 = 10.1972G Pressure 1MPa = 10.1972kgf/cm2 Cylinder thrust/load 100N = 10.1972kgf Standard air: Symbol (ANR) Torque 1Nm = 10.1972kgfcm Temperature 20C {293K}, Air with Moment of inertia 1kgm2 = 10.1972kgcm/s2 an absolute pressure of 760 mmHg Kinetic energy 1J = 10.1972kgcm {101.3kPa}, and
With the 0.1 W specification, the vibration and impact resistance is 10/50 m/s2 or less. Note 3) With the low vacuum specification, the operating pressure range is 1.33 102 Pa to the maximum operating pressure.
(Between lead wire and the case) 1000 m/s2 300 m/s2 Impact resistance 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute 1) (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Withstand voltage Except magnetic resistant 2-color indication type solid state switch (DP5DWL/P5DWSC).
ripple 10% or less) Current consumption 20mA or less (without load) Enclosure IP65 Operating temperature range Operating: 0 to 50C, Stored: 25 to 85C in stock (no freeze nor condensation) Environmental resistance Voltage resistance 1000VAC for 1 min between external terminals and case Insulation resistance 50M or more (500VDC) between external terminals and case Vibration resistance 4.9m/s2
2.5% F.S. or less Note 3) No-voltage input (solid state switch or reed switch), input 5ms or more IP65 Operating: 0 to 50C, Stored: 10 to 60C (With no condensation or freezing) Operating and stored: 35 to 85% RH (With no condensation) 250VAC for 1 min, between all lead wires and enclosure 2M or more (at 50VDC) between all lead wires and enclosure 10 to 500Hz with 1.5mm amplitude or 98m/s2
Mount the switch in a locations where there is no vibration greater than 98 m/s2 or impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.
Do not drop, bump or apply excessive impacts (980 m/s2 or more for sensor unit and 98 m/s2 or more for amplifier unit) while handling. Although the trimmer auto switch body may not be damaged, the inside of the trimmer auto switch could be damaged and cause a malfunction. 2. Refer to the Operation Manual for how to adjust/set. Maintenance Warning 1.
P1 LED lever meter Sensor S1 S3 Red is on: Output OFF Green is on: Output ON S4 S2 + P2 Red 1 Gap too big S1, S2: Fixed orifice S3: Variable orifice (Set via adjustment knob) S4: Detection nozzle Red 2 Green 1 BEST POSITION The bridge circuit is constructed as shown in the diagram. Position the work piece in front of the nozzle (S4).
Do not drop or apply the excessive force (1000 m/s2) to a switch when handling. Do not drop, or bump, or apply the excessive force (more than 1000 m/s2) when handling a switch. The internal parts of a switch are damaged, and may result in a malfunction, even though a switch case itself is not damaged. 2. When handling a switch, hold it by the switch body.
With the 0.1 W specification, the vibration and impact resistance is 10/50 m/s2 or less. Note 3) With the low vacuum specification, the operating pressure range is 1.33 102 Pa to the maximum operating pressure.
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Auto feed lube series ALF400 - 900 makes lubrication work unnecessary, thus significantly reducing the amount of maintenance labor. The problem of running out of oil is prevented because the oil is fed automatically. Auto feed lube, metric style, Rc (PT) threads, Body sizes: 1/2, 3/4, 1, 1+1/2, 2, Bracket option available LUBRICATOR, AUTO FEED LUBE.
Cyl, Air Slide Table. 900 lb. D87.
Series: LEKFS, Size: 40, Motor Mounting Position: L (Left Side Parallel), Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 900, Motor Option: B (with Lock), Seal Band Stopper: N [Roller Type Seal Band Stopper [Grease Free]], Actuator Cable Type, Length: RA (10), Controller: C91 (JXC91, EtherNet/IPâ„¢ Direct Input
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN