/M5W/M5TL D-E7A/E80A D-M5, D-M5W, D-M5TL D-E7A, D-E80A D10 15 5 10 1 pc. 2 pcs.
H (Conduit terminal: T) I (DIN terminal: D) Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S T U Model VNA2-10A VNA2-15A VNA3-20A VNA4-25A 3 8 1 2 3 4 63 144.5 55 125.5 52 42 26 29 4.5 14 24.3 72.5 2.3 80.5 25 75 34 80 84.5 124 135.5 151.5 137 153 156 172 60.5 73 1 80 90 62 72 50 60 31 36 35 40 5.5 6.5 17.5 20 28.3 33.3 84 100 2.3 2.3 92 108 30 35 84 90 43 49 89 95 93.5 99.5 Port
D-A5/A6, D-A59W Tie rod mounting D-G3/K3 Band mounting Solid state swich D-F5/J5, D-F5NT, D-F5W/J59W, D-F5BA, D-F5F Tie rod mounting 1.10-1 Air Cylinder/Standard Series CS1 Lube, Non-lube: 125, 140, 160, 180, 200, 250, 300 Air-hydro: 125, 140, 160 How to Order CS1 L 300 160 JR Rod boot/Cushion Rod boot Mounting J K N R H Nylon tarpaulin Heat resistant tarpaulin No cushion With cushion on
Alarm group E OFF OFF Power supply for control is turned OFF Supply power again Procedure to restart operation when alarm group D is generated Procedure 1: Alarm group D is generated "SVRE" changes to OFF (Servo is OFF) Procedure 2: Turn ON RESET (The alarm is cancelled) After turning ON SVON, SVRE turns ON (Servo is ON). -63No.
(V), D-A93(V), D-A96(V) (mm) Lead wire entries outside A A Model Mounting Auto switch operating range A B A B A B 54 MXY6 34 MXH 59 5 MXY8 39 MXU 67 MXY12 47 MXS Solid State Auto Switch D-M9B(V), D-M9N(V), D-M9P(V) Lead wire entries inside MXQ (mm) B B Model Mounting Auto switch operating range MXF A B A B A B 50 MXY6 3 38 MXW 55 MXY8 3.5 43 MXJ 63 MXY12 3 51 MXP Lead wire entries parallel
--T 153 71 105.5 90 89 -45No.PF-OMN0009CN-F PF3W511-U25/PF3W521-U30(PVC ) 2X A B D E F J K L N P Q 25 A 154 46 77 57.6 23 77 63 28 18 3.5 14 32 30 A 146 56 91 71.6 28.5 73 60.5 25 27.5 3.5 14 38 S T U V W Y Z 25 A 59 36 48 58 70 7 2 -46No.PF-OMN0009CN-F M8 (ZS-40-A) ()4 ()3 1() -47No.PF-OMN0009CN-F EPDM EPDM 11 11 PVC 420 mA 2 420 mA 11 PVC -48No.PF-OMN0009CN-F Revision history
The signal has to be converted by a A/D converter for pressure display or switch output. Current Output signal is a current signal in the range of 4 to 20[mA]. The signal is transformed into a voltage signal before being converted by a A/D converter for pressure display or switch output.
Tie-rod base SS5V 10 1 A2W W D 05 U 10S Cassette base SS5V 10 W U D 05 16S 1 A2W Clean series DIN rail length specified Enclosure IP67 Standard length Nil 3 Series For 3 stations Specify a longer rail than the standard length. 1 2 10-SV1000 10-SV2000 16 For 16 stations SI unit 0 Without SI unit DeviceNet/PROFIBUS DP/ EtherNet/IP A2W Valve stations P, E port location Symbol 02 Stations
Refer to the power supply specification for the size of the acceptable electric wire. [2] Connect the motor cable (U, V, W) to the servomotor connection terminals (U, V, W). Connect the motor ground terminal to the driver ground terminal. Connect the encoder cable to the encoder cable connector.
Tie-rod base SS5V W 1 A2W D 05 U 10S Cassette base U SS5V W D 05 16S 1 A2W Enclosure IP67 specifications DIN rail length specified Series Standard length Nil 3 SI unit 1 2 SV1000 SV2000 Specify a longer rail than the standard length.
D J Bracket (Option) AR20(K)-B to AR40(K)-06-B 2 x P1 Panel fitting dimensions A (Port size) Y W C B Q V K OUT OUT IN IN Z Plate thickness AR20(K)-B to AR30(K)-B: Max. 3.5 AR40(K)-B : Max. 5 R F P2 S (Pressure gauge port size) Bracket (Option) U M J D T N AR50(K)-B/AR60(K)-B 2 x P1 A (Port size) B Q C K OUT IN R F P2 S (Pressure gauge port size) Bracket (Option) T N J M D U 73 Regulator Series
Option Applicable model 10-/21-AF20-A 10-/21-AF30-A 10-/21-AF40-A 10-/21-AF40-06-A 10-/21-AF50-A 10-/21-AF60-A Bracket assembly Note 2) AF52P-050AS AF22P-050AS AF32P-050AS AF42P-050AS AF42P-070AS Note 2) Assembly includes a bracket and 2 mounting screws. 1069-1 A Air Filter 1021-AF-A Dimensions AF20-A AF30-A to 40-06-A 10211021T N S J M U D J M U D S N T Air Preparation Equipment Pressure
0 o u r e !3 !1 u u TMH r t r t ASD e !3 e !3 AS q AS-FE !1 !1 i !4 y q q KE i !5 i !5 AS-FG AS-FP AS-FM AS321F-02 Meter-out type AS3201F-02 Meter-in type AS3211F-02 AS-D AS-T ASP ASN AQ ASV AK VCHC ASR ASQ Component Parts No.
0 i y u q o !0 i y Component Parts No. Description Material Note 1 Body A PBT 2 Knob POM 3 Body B PBT 4 Needle PBT 5 Needle guide Stainless steel 6 U-seal HNBR 7 Spacer PBT1 Component Parts No.
7.3 D C B A PD port size Metric size: Rc1/8 Inch size: NPT1/8 Supply Port Dimensions [mm] Dimensions [mm] N C4 4.7 C6 4.7 N3 4.7 N7 7.3 A B C D E F ZHP63BM 26 45.8 63 68 12.5 33.8 ZHP80BM 28 57 80 85 18 41.8 ZHP63UM 26 63 66 5 20.3 ZHP80UM 26 80 83 5 20.3 Circuit Adapter Dimensions (by Mounting Style) [mm] G H J K L M ZHPmmmA-mmS 25.7 22.6 5 13 M8 ZHPmmmB-mmS 27.1 21.2 6 17 M10 ZHPmmmC-mmS
Fluid passage dia.: P R J K 2 x L H I O 4 x Sa Thread depth Sb G M N A D F Vacuum flow Dust bag When dust bag is mounted E T Suction air Suction air Discharge air B C C U Hose band V Note 1) (mm) A 158 B 70 C 50 D 20 E F 24.5 G 60.5 H 5 I 70 J 60 K 5.5 L 72 M 37 N 2 O 30 P Rc1/4 Q R 59 Sa Sb T 500 U 250 V 310 Model ZH30--X185 ZH40--X185 28.5 146.5 M4 x 0.7 10 203 90 64 25 27.2 33.5 196.8
D -With Built in Magnet (Not available as std. on single acting models, XB6 & XB7) I XBg -Low Friction I XCO -Stainless Steel Rod LNumber of Auto-swircnes -2 pcs. S 1 p c . n n p c s . L Long leads uountng B Front Nose Mount C -Rear Pivot E -Double End K -Non-Rotating Rod R -Block Mount W-Double Rod Auto.Switch 853. D-853 Gsg D-G59 B54. D-854 K59 D-K59 864 .
D -With Built in Magnet (Not available as std. on single acting models, XB6 & XB7) I XBg -Low Friction I XCO -Stainless Steel Rod LNumber of Auto-swircnes -2 pcs. S 1 p c . n n p c s . L Long leads uountng B Front Nose Mount C -Rear Pivot E -Double End K -Non-Rotating Rod R -Block Mount W-Double Rod Auto.Switch 853. D-853 Gsg D-G59 B54. D-854 K59 D-K59 864 .
PEND Petroleum CW-6H Water-glycol, Emulsion For 2 1/2B, 3B CW-6H-W Phosphoric ester CW-6H-V Petroleum D-73H Water-glycol, Emulsion For 1/2B to 1B D-73H-W Phosphoric ester D-73H-V Petroleum D-74H Cap Water-glycol, Emulsion For 1 1/4B to 2B D-74H-W Phosphoric ester D-74H-V Petroleum D-75H Water-glycol, Emulsion For 2 1/2B, 3B D-75H-W Phosphoric ester D-75H-V 506 Suction Guard FHG Series How
(Cable length) Product image Both straight Both angle Number of functional poles M12: 4 pins Key type M12: D-coded 1 2 1 (Yellow) : TD+ 2 (White) : RD+ 3 (Orange) : TD 4 (Blue) : RD Pin assignment 3 4 Plug, D-coded (Viewed from the plug) Fixed cable length 0.5 m, 1 m, 2 m, 3 m, 5 m, 10 m Wiring Cable O.D. 6.5 mm Conductor nominal cross section 0.34 mm2/AWG22 Wire O.D.