SMC Corporation of America
Elite Part Number Search
Search Results "ISE76G-F02-L2"

Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.

L2 = 21 x m + 89.8 L1 = 10.5 x n + 45 Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Default settings At the time of factory shipment, the product is in "Remote Control Mode" and set to "Enable DHCP".

Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.

HRLE050 200V N L HRLE090 200V L3 L1 L2 Fig. 3-12 Cable wiring (200V) 3.3 Installation Procedure HRLE Series 3-16 HRX-OM-Z002 Chapter 3 Transport and Set Up 400V L1 L2 L3 Fig. 3-13 Cable wiring (400V) HRLE Series 3.3Installation Procedure 3-17 HRX-OM-Z002 Chapter 3 Transport and Set Up 3.3.4 Preparation and wiring of communication cable Be sure to turn OFF the breaker of the facility power

/Z1 (CN2) (CN1) 1 1 3 3 2 2 4 4 3 2 1 3 2 1 4 4 2 1 1 3 2 1 6 8 3 5 7 2 4 2 1 1 3 2 USB Board PCB4 Display Board PCB3 BK BR RD RD RD RD BL BK BK RD RD WH Not connected at option Z 24COM AOUT +24V + OUT (CN1) 3 6 2 5 4 1 BR BR BL BL Option DM DI Sensor Level Switch Level Switch Water Leak Sensor BL BR WLS LS1 LS2 Solenoid Valve DI SVDI Option DM BL 11 FWD 12 CM 30C 30B G G4 [ ] 18AWG G/Y L2

Connect the stripped cable to the L, N, PE terminals(For 400V, L1, L2, L3, PE) of the female connector. (Recommended tightening torque: 0.7 Nm) Female connector Screw (Recommended thightening torque : 0.7Nm) PE 2(N) 1(L1) 1(L) 2(L2) PE 3(L3) 200V type 400V type Fig 3-5 Cable connection HRR Series 3.3 Installation 3-11 HRX-OM-X071 Chapter 3 Transport and Setting Up 5.

Dimensions C D L1 L2 Fd Fc C Fn (Fc) (KF Flange) (K Flange) (CF Flange) K B J H A G A Unit: mm Model A B C D Fn Fd Fc G H J KK P.C.D.

Dimensions XMH series / Angled Valve C D L1 L2 A Fn Fc C (Fc) (CF Flange) (KF Flange) H J H B G A Unit:mm Table 5 Model A B C D Fn Fc G H J P.C.D L1 L2 XMH-16 40 100.5 38 1 30 34 17 35 18 P.C.D 27 6x4.4 XMH-25 50 114 48 1 40 26 41 21.5 XMH-40 65 162.5 66 2 55 70 41 57 30 P.C.D 58.7 6x6.6 XMH-50 70 179.5 79 2 75 52 70 35 XYH series / Straight Valve D G C C B H Fn J (KF Flange) 45 Unit: mm

. 2. 3. 1. 2. 3. 4. 3 *3) 1 1.5 3) 1 1 () 4 1 1-1 MXQ6 MXQ8 MXQ12 MXQ16 MXQ20 MXQ25 1) 2) ( ) 3) 4) / / 2 ,3 ) 2 2 ,3 ) 1) 1 2) 20 ,0.150.6MPa 3) MXQ25(A)-150,MXQ6B-50,75MXQ8B-75,100MXQ16B-100,150MXQ20B-125,150 300mm/s 4) MXQ**B 50200mm/S 1 (MPa) MXQ8(A,C) 0.3 MXQ8B 0.3 MXQ12(A,C) 0.3 MXQ12B 0.3 MXQ16(A) 0.2 MXQ16B 0.2 MXQ20(A) 0.2 MXQ20B 0.2 MXQ25(A) 0.2 5 2. 2-1 ,2 L1 L2

/ mm mm mm c.p.m. mm(L1-L2) (L1) (L2) g MHL2-10D 60 20 56 76 280 MHL2-10D1 40 78 118 345 10 40 MHL2-10D2 60 96 156 425 MHL2-16D 60 30 68 98 585 MHL2-16D1 60 110 170 795 16 40 MHL2-16D2 80 130 210 935 MHL2-20D 60 40 82 122 1,025 MHL2-20D1 80 142 222 1,495 20 40 MHL2-20D2 100 162 262 1,690 MHL2-25D 60 50 100 150 1,690 MHL2-25D1 100 182 282 2,560 25 40 MHL2-25D2 120 200 320 2,775 MHL2-32D

Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.

Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.

Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.

Installation example n,m L 0 1 2 3 4 5 6 7 8 9 10 L1 45 55.5 66 76.5 87 97.5 108 118.5 129 139.5 150 L2 89.8 110.8 131.8 152.8 173.8 194.8 215.8 236.8 257.8 278.8 299.8 n,m L 11 12 13 14 15 16 L1 160.5 171 181.5 192 202.5 213 L2 [mm] : L1 shows the dimensions of the VQC1000 series solenoid valve.

Dimensions for installation n: number of solenoid valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series solenoid valve manifold. -11No.EX-OMW0016-A Wiring

Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.

Please refer to an individual catalog for the size when other manifolds are connected. n_m L 0 1 2 3 4 5 6 7 8 L1 45 55.5 66 76.5 87 97.5 108 118.5 129 L2 89.8 110.8 131.8 152.8 173.8 194.8 215.8 236.8 257.8 n_m L 9 10 11 12 13 14 15 16 L1 139.5 150 160.5 171 181.5 192 202.5 213 L2 278.8 299.8 Wiring (for power supply, communication and input) and piping are done on only one side.