This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, ROTARY, CLAMP, ACTUATOR, MKA/MKB CLAMP CYLINDER, HE, 20MM MKA/MKB DBL ACT-AUTO-SW, 1.13905 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, ROTARY, CLAMP, ACTUATOR, MKA/MKB CLAMP CYLINDER, NE, 50MM MKA/MKB DBL-ACT AUTO-SW, 3.47840 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, ROTARY ACTUATOR, AUTO-SW, ACTUATOR, CRQ2 ROTARY ACTUATOR, ME, 40MM CRQ2 DBL-ACT AUTO-SW, 5.51155 lb
Magnet: D (Built-in), Mounting: C (MP4, Single Detachable Rear Clevis), Bore Size: 325 (3 1/4"), Stroke: 0700 (7"), Air Cushion: Both Ends (Air Cushion), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.), X Option: XC6 (Stainless Steel Rod)
Magnet: D (Built-in Magnet), Mounting: C (Rear Pivot Mount), Bore: 088 (7/8"), Stroke: 0300 (3"), Cushion: No Cushion, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: D (Built-in Magnet), Mounting: C (Rear Pivot Mount), Bore: 075 (3/4"), Stroke: 0050 (1/2"), Cushion: No Cushion, Rod Boot: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.), Mounting Options: X155US (Rear Pivot Mount w/o Clevis Pin)
Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore: 125mm, Port Thread: Rc, Stroke: 250mm, Cushion: K (Rod Boot, Heat Resistant Tarpaulin), Pivot Bracket: N (Pivot Bracket), Rod End: W (Double Knuckle Joint), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore: 125mm, Port Thread: Rc, Stroke: 25mm, Cushion: K (Rod Boot, Heat Resistant Tarpaulin), Pivot Bracket: N (Pivot Bracket), Rod End: W (Double Knuckle Joint), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 50mm, Port Thread Type: F (Built-in One-touch Fittings), Stroke: 100mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: L (Shipped Together), Rod End Bracket: D (Simple Joint A Type + Joint), Auto Switch: M9B
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 50mm, Port Thread Type: F (Built-in One-touch Fittings), Stroke: 50mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: L (Shipped Together), Rod End Bracket: D (Simple Joint A Type + Joint), Auto Switch: M9B
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes *: 12
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes *: 12
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes *:
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, ML, 40MM CQ2-Z NON-ROT AUTO-SW, 1.70858 lb
Magnet: D (Built-in), Series: J2, Mounting: L (Single Foot), Bore Size: 10mm, Stroke: 150mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: V (Single Knuckle Joint), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.), Auto
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead
Magnet: Built-in Magnet, Mounting: Head Flange, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 400mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc., Made to Order: w/Heavey Duty Scraper
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead