SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2D100-1000-D"

(Example: When the value can be displayed down to 0.001 MPa for the product for 0 to 1 MPa, the resolution is 1/1000) Display resolving power Displayed pressure value can be adjusted within the range of 5%R.D. (5% of displayed value).

Attenuation rate 1000 ft (max.) 28 / 1000 ft (max.) 17.5 / Conductor resistance 6.9 / 1000 ft (max.) 3.6 / 1000 ft (max.) Bus cable type Baud rate Total main line length Branch line length Total main and branch line length 500 kbps 100 m max. 39 m max. Thick 250 kbps 250 m max. 78 m max. 6 m max. 125 kbps 500 m max. 156 m max.

D Shows how precisely the pressure can be indicated or set by the digital Pressure switch. When 1 digit = 1 kPa, the pressure is given with an increment Digit (Min. setting unit) of 1 kPa, e.g., 1, 2, 3,, 99, 100. E Energy saving automatic control Indicate that the vacuum pressure during adsorption is monitored and ON and OFF of the ejector is automatically controlled.

Remove water droplets from the inlet air Water droplets in the air can lower performance and cause malfunction. d. Large quantities of dust (solid foreign matter) are contained in the supply air. When there are large quantities of dust (solid foreign matter), install an air filter or main line filter to the inlet side of the mist separator. e.

or less 1000 or less XC22 Fluororubber seal 140 1600 or less 1000 or less 1000 or less XC26 Clevis pins with flat washer 160 Double clevis pin and double knuckle pin made of stainless steel 1600 or less 1200 or less 1200 or less XC27 180 2000 or less 1200 or less Rod side trunnion XC30 200 2000 or less 1200 or less With coil scraper XC35 250 2400 or less 1200 or less Hard chrome plated

Refer to the LECA Operation Manual for installation. e CC-Link direct input type (LECPMJ) is not CE-compliant. t Lead [mm] Symbol LEFS16 LEFS25 LEFS32 LEFS40 A 10 12 16 20 B 5 6 8 10 y Stroke [mm] 50 50 to to 1000 1000 * Refer to the applicable stroke table.

Symbol LEFS16 LEFS25 LEFS32 LEFS40 A 10 12 16 20 B 5 6 8 10 Stroke [mm] 100 100 to to 1000 1000 Refer to the applicable stroke table. [UL-compliant products] When conformity to UL is required, the electric actuator and controller/driver should be used with a UL1310 Class 2 power supply.

D Shows how precisely the pressure can be indicated or set by the digital Pressure switch. When 1 digit = 1 kPa, the pressure is given with an increment of Digit (Min. setting unit) 1 kPa, e.g., 1, 2, 3,, 99, 100. E Energy saving automatic control Indicate that the vacuum pressure during adsorption is monitored and ON and OFF of the ejector is automatically controlled.

D Shows how precisely the pressure can be indicated or set by the degital Pressure switch. When 1 digit = 1 kPa, the pressure is given with an increment of Digit (Min. setting unit) 1 kPa, e.g., 1, 2, 3,, 99, 100. E Energy saving automatic control Indicate that the vacuum pressure during adsorption is monitored and ON and OFF of the ejector is automatically controlled.

D Shows how precisely the pressure can be indicated or set by the digital Pressure switch. When 1 digit = 1 kPa, the pressure is given with an increment of Digit (Min. setting unit) 1 kPa, e.g., 1, 2, 3,, 99, 100. E Energy saving automatic control Indicate that the vacuum pressure during adsorption is monitored and ON and OFF of the ejector is automatically controlled.

D Shows how precisely the pressure can be indicated or set by the digital Pressure switch. When 1 digit = 1 kPa, the pressure is given with an increment Digit (Min. setting unit) of 1 kPa, e.g., 1, 2, 3,, 99, 100. E Energy saving automatic control Indicate that the vacuum pressure during adsorption is monitored and ON and OFF of the ejector is automatically controlled.

(Example: If a product for 0 to 1 MPa can indicate pressure by 0.001 MPa, the indication resolution is 1/1000.) Indication resolution Indication LED The LED that turns on when the switch output is ON. Indication unit The unit of pressure used in the display. 11 - NO. ZQ-OM01501 No.

VDC Pressure Characteristics Pressure Characteristics 1 i 6 _ 102 9 s 3 o t 5 o 1000 2000 3000 4000 5000 F ow rale f/min(ANBI 20 30 40 200 400 600 400 looo Fow rale i/m n(ANF) 1 3 1 102 e7 T3 d 7 3 58 a a a 29 1 5 1 5 o 4 8 1 2 1 6 2 A 2 4 2 8 400 800 1200 1.in 2004 2400 200 400 600 800 1000 Belief flo\i/ i.

Stroke [mm] 100 to 1000 100 to 1000 [UL-compliant products] When conformity to UL is required, the electric actuator and controller/driver should be used with a UL1310 Class 2 power supply. Refer to the applicable stroke table.

(Example: When the value can be displayed down to 0.001 MPa for the product for 0 to 1 Mpa, the resolution is 1/1000) Display resolving power Displayed pressure value can be adjusted within the range of 5%R.D. (5% of displayed value).

Also, one piece of amp "HPX-EG00-1S-L02" manufactured by Azbil Corporation is required for one sensor to detect the fluid leakage (two amps are required in total). 14 Revision 18-Aug-2020 Revision D Completely revised by format change.

Also, one piece of amp "HPX-EG00-1S-L02" manufactured by Azbil Corporation is required for one sensor to detect the fluid leakage (two amps are required in total). 13 Revision 18-Aug-2020 Revision D Completely revised by format change. Change the part number of amp for the sensor.