Applied voltage When connecting fittings to valves, tighten as indicated below. 1) M3, M5 types 1. When using SMC fitting, follow the guidelines below. After tightening by hand, tighten an additional 1/4 (M3), 1/6 (M5) turn with a tightening tool. However, if miniature fittings are used, tighten an additional 1/4 turn with a tightening tool after tightening by hand.

from above / through hole type Screw material SUS Screw dimensions M2.5 x 0.45 Recommended tightening torque [Nm] 0.27 to 0.36 L3 (Maximum screw-in depth) [mm] 2.5 L4 (Plate thickness) [mm] 2.1 3 Work piece mounting / top mounting type Screw material SUS Screw dimensions M3 x 0.5 Recommended tightening torque [Nm] 0.48 to 0.63 L5 (Maximum screw-in depth) [mm] 2.5 (5) When connecting the

SYJ7000 M3 0.8Nm Caution Replacement of Pilot Valve Pilot valve in this series are improved to provide excellent energy saving results. However following this improvement, these new valves are no longer compatible with the conventional pilot valve used at the interface.

Keep the air flow within the rated flow to prevent an outflow of lubricant to the outlet side Note2 When compressor oil mist discharge concentration is 30mg/m3 (ANR). Note3 Bowl seal and other O-rings are slightly lubricated.

Class B coil: AWG20 Insulator O.D. 2.5 mm Terminal cover Round head combination screw M3 Tightening torque: 0.5 to 0.6 Nm mark mark Tightening torque: 0.5 to 0.6Nm Round head combination screw M3 Tightening torque: 0.5 to 0.6Nm Conduit terminal Cross section A-A (Wiring inside) Lead wire Seal Conduit piping (Port size G1/2 Tightening torque 0.5 to 0.6Nm) Rated voltage Lead wire color (1)

Keep the air flow within the rated flow to prevent an outflow of lubricant to the outlet side Note 4 When the compressor oil mist discharge concentration is 30 mg/m3 (ANR). Note 5Bowl seal and other O-rings are slightly lubricated.

Manually unlocking For 20 to 32 Dust cover holding bolt Dust cover Manual unlocking bolt Manual unlocking bolt Lock ring Locking direction Locking direction Lock ring Rod side Head side Rod side Head side MLGP--F: Extension locking MLGP--B: Retraction locking 1) Remove the dust cover. 2) Screw a manual unlocking bolt (a bolt of M3 x 0.5 x 15L of more commercially available) into the lock

See Fig. 4] For FN112-10, two screws are mounted in the middle of the guide assembly [M3 See Fig. 4] 2-6. The element can now be pulled out of the cover. Do not disassemble the element any further. Note) Reassembly should be performed by reversing the disassembly procedure. Refer to the schematic drawings for the assembly and disassembly procedures for the cover, seals etc.

Standard Strokes Stroke (mm) Bore size (mm) Bore size (mm) Mounting bracket Applicable switch Note 50 100 75 125 150 175 200 250 300 400 500 25 Switch mounting screw (M3 X 0.5 X 8 l ) Square nut 12 V V V V V V D-A7, A8 D-A7lH, A80H D-A73C, A80C D-A79W D-F7lV D-F7, J7 D-J79C D-F7lWV D-F79W, J79W 12 20 BQ-1 20 V V V V V V V V 32 V V V V V V V V V Switch mounting screw (M3 X 0.5 X 10 l )

X 0.5 M10 X 1.0 9 18.5 25.5 32.5 3 27.5 34.5 41.5 3 10 19 22 6 14.5 21 28 12 12 3.5 M4 X 0.7 M15 X 1.5 13 20.5 27 34 4 32.5 39 46 5 12 27 31 7 16.5 22.5 29 19 14 4.2 M5 X 0.8 M22 X 1.5 20 23.5 29.5 36 5 37.5 43.5 50 6 Plug Mounting Style CJPS B C E G H K MM NN 5st 10st F 15st R 5st 10st S 15st W Q 5st 10st Z Bore (mm) 6 10 15 A 15st 7 12 13.9 6 12.5 19.5 26.5 8.5 9 3.5 M3 X 0.5 M10 X 1.0

Universal mounting Model Model Size (Nominal x Height) Piece Metric size Inch size TMH-23J TMH-04J TMH-06J TMH-06 TMH-01J TMH-03J TMH-05 TMH-07 TMH-09 TMH-11 TMH-13 M3 x 15 M3 x 20 1 M4 x 25 TMH-08 TMH-10 TMH-12 The holder can be used to secure an individual part.

A I 18 6 21 9 5 5 23 34 Side A Side B 12-11-13 14 Series MRHQ Dimensions MRHQ16 A B 41 50 66.5 4-M5 x 0.8 depth 8 30 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0 -0.062 47h9 +2.2 -0.2 20.9 opened 0 -0.1 5 41 +0.03 0 3-4H9 depth 6 (one each on three sides) 4-M3

Tighten the screws (M3) for mounting the blank cover in the range of 0.3 0.03Nm. Failure to observe these torque values could lead to equipment damage.

Specifications Compressed air 1.0MPa Fluid Max. operating pressure Min. operating pressure(1) 0.05MPa 1.5MPa Proof pressure Ambient and fluid temperature 5 to 60C Filtration 0.3m (95% particle size collection) Max.1.0mg/m3(ANR) (08ppm)(2) Oil mist removal rate 2 years or when pressure drop reaches 0.1MPa Element life Note 1) With Auto drain: 0.15MPa Note 2) At oil mist removal rate blowing

8000 AMD801 24000 AMD901 Model Rated flow (l/min(ANR)) Port size (Nominal size B) Weight (kg) 2B Flange 2B/3B/4B Flange 50 140 Specifications Compressed air 1.0MPa Fluid Max. operating pressure Min. operating pressure(1) 0.05MPa 1.5MPa Proof pressure Ambient and fluid temperature Filtration 5 to 60C Order Made P.4.6-14 0.01m(95% particle size collection) Oil mist removal rate Max.0.1mg/m3

valve Measurement distance: 1m R(PT) R(PT) M3 M5 1 8 1 8 Port size Fluid Noise reduction dB(A) 16 21 13 18 Compressed air Max. operating press Ambient and fluid temperature 1.0MPa 5 to 50C Effective area (mm2) Weight (g) Dimensions (mm) 20 35 1 5 9.5 20 1 3.3 22.5 38 9 17 11 A B 13 6 8 Note) NPT thread for AN101 and AN110 is alsoavailable.

Note 2) When the compressor oil mist discharge concentration is 30mgf/m3 (ANR). Accessory part no. Accessory Applicable model AFD40 AFD20 AFD30 AFD40 AFD40-06 Note 1) Bracket assembly AF20P-050AS AD27 AF30P-050AS AD38 AD37 AF40P-050AS AD48 AD47 AF40P-070AS AD48 AD47 N.O. N.C. Note 2) Float type auto drain Note 1) Assembly includes a bracket and 2 mounting screws.

Tightening of M3, M5, and M6 screws 1) M3 After tightening by hand, tighten an additional 1/4 rotation with a tool. 2) M5 and M6 After tightening by hand, tighten an additional 1/6 rotation with a tool. Over tightening can cause damage to the threads and/or air leakage due to deformation of the gasket. Under tightening can cause loose threads and air leakage, etc. 1.

Moment (Nm) Payload (N) ML1C/M2,M3 How to calculate the load ratio A. Consider q Max. payload, w static moment, e dynamic moment (when stopper collides) when calculating the Max. allowable moment and payload. Evaluate q and w as a (average speed), and e as (collision speed =1.4a).

plate Retainer Spool valve Piston Spring Sub-plate Note Platinum silver Platinum silver Platinum silver No. q w e r t y u i Material Aluminium die-casted Aluminium die-casted Aluminium die-casted Brass Aluminum/NBR Resin Stainless steel Aluminium die-casted Platinum silver How to Order Sub-plate Replacement Parts Series Sub-plate Hexagon socket head bolt Gasket for sub-plate VP 00 2 3 P 1 M3