Control Method: S (Meter-in, Light Blue), Stud Position: B (Left Side), Tube Diameter: 06 (ø6), Thread Type: R, Port Size: M5 (M5 x 0.8)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: B (Out 1: PNP, Out 2: Flow Rate: PNP, Temp.: None, Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G (Instantaneous Flow: gal/min, Accumulated Flow: gal.
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature:
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 06 (3/4), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C),
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: A (Out 1: NPN, Out 2: Flow Rate: NPN, Temp.: None,Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 06 (3/4), Output Specification/Temperature Sensor: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature:
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: R
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: Instantaneous Flow: L/min, Temperature
.: 06 (ø6), Residual Pressure Release Function: without Residual Pressure, Thread Type: Rc, Size: 01 (1/8), Seal Method: S (w/Sealant)
.: 06 (ø6), Residual Pressure Release Function: without Residual Pressure, Thread Type: Rc, Size: 02 (1/4), Seal Method: S (w/Sealant)
.: 06 (ø6), Residual Pressure Release Function: without Residual Pressure, Thread Type: Rc, Size: 01 (1/8), Seal Method: S (w/Sealant)
.: 06 (ø6), Residual Pressure Release Function: E (w/Residual Pressure), Thread Type: Rc, Size: 01 (1/8), Seal Method: S (w/Sealant)
.: 06 (ø6), Residual Pressure Release Function: E (w/Residual Pressure), Thread Type: Rc, Size: 01 (1/8), Seal Method: S (w/Sealant)
.: 06 (ø6), Residual Pressure Release Function: E (w/Residual Pressure), Thread Type: Rc, Size: 02 (1/4), Seal Method: S (w/Sealant)
.: 06 (ø6), Residual Pressure Release Function: without Residual Pressure, Thread Type: Rc, Size: 02 (1/4), Seal Method: S (w/Sealant)
Body Size: 5000, Port Thread: N (NPT), Port Size: 06 (3/4), Option: S (Silencer), Flow Direction, Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Indicator: S, Control Method: E (Meter-out), Stud Position: A (Right Side), Tube Diameter: 06 (ø6), Thread: R, Port Size: M5 (M5 x 0.8)
Indicator: S, Control Method: E (Meter-out), Stud Position: A (Right Side), Tube Diameter: 06 (ø6), Thread: G (F), Port Size: 01 (1/8)
Indicator: S, Control Method: E (Meter-out), Stud Position: B (Left Side), Tube Diameter: 06 (ø6), Thread: R, Port Size: M5 (M5 x 0.8)