Grease pack part no.: GR-S-010 (10 g) Cylinder body Piston seal 20 is a non-replaceable part, so it is not included in the seal kit. Rod seal CXWM20-PS CXWM20-PS CXWM32-PS CXWM20 CXWM32 Set of left nos. !7, !8, !9 NBR CXWM32-PS Cylinder tube gasket Piston gasket With End Lock Body gasket !2 !3 !4 !
Magnetically Coupled Rodless Cylinder/Slider Type: Ball Bushing Bearing Series CY1L Replacement Procedure is 6, 10, 15, 20 25, 32, 40 P.318 Construction Slider type, ball bushing bearing CY1L6 $0 #9 #8 $1 CY1L10 to 40 #9 $0 $2 #8 $0 #7 $1 F G G unit (10) 10,15 Enlarged view F $1 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series CY1L.
8 Note 1) AS21FE type is electroless nickel plated. Note 2) Meter-in type is black zinc chromate plated. Note 3) Only for AS21FE-01. Note 4) AS231FE-01 (4, 6) is POM. 15-9-38 4 Speed Controller with Residual Pressure Release Valve with One-touch Fitting, Elbow Type/Universal Type Dimensions Elbow type Model Weight (g) T H1 H2 D1 D2 L1 L2 L3 L4 A M1 Max. Min. Max. Min.
Model r e b m u N A f o t r o P l e d o M g n i t r o P e z i s t r o P B e z i s t r o P A c i r t e M " 2 3 / 5 " 4 " 4 / 1 " 6 " 6 1 / 5 " 8 t r o P A t r o P B h c n I 1 1 M K h c u o t e n O g n i t t i f g n i t t i f h c u o t e n O 0 1 , 6 6 1 / 5 8 8 / 3 0 1 2 / 1 2 1 2 1 M K h c u o t e n O g n i t t i f d a e r h t T P N 0 1 , 6 4 / 1 T P N ) T P ( c R 4 / 1 d a e r h
Rod seal NBR 21 is a non-replaceable part, so it is not included in the seal kit. Piston seal NBR Seal kit includes !8, !9, @0 and @2. Order the seal kit based on each bore size. Do not disassemble the trunnion style. Seal kit includes a grease pack (40, 50: 10 g, over 63: 20 g). Order with the following part number when only the grease pack is needed.
Contents Bore size (mm) REBH15-PS REBH25-PS REBH15-PS REBH25-PS 15 25 Set of left nos. @9, #0, #1, #2, #3, #4, #5 @9 #0 #1 #2 #3 #4 #5 Wear ring A Special resin Wear ring B Special resin Note) Cushion seal #5 may be difficult to be replaced. Seal kit includes a grease pack (10 g). Order with the following part number when only the grease pack is needed.
Applicable model M-5N AS1000 Nipple Note) AS1000 with nipple: AS1000-M5-N How to Order M5 AS 1 000 Option Body size H (1) High temperature (5 to 80C) 1 2 3 4 5 M3, M5 standard L (2) Low temperature (30 to 60C) 1 8 1 4 , standard standard standard standard Note 1) AS5000 is available as special. AS1000 is not applicable.
/O.D. mm Part no. 5/8 6/9 6.5/10 5/8 6/9 6.5/10 8/12 8.5/12.5 5/8 6/9 6.5/10 5/8 6/9 6.5/10 8/12 8.5/12.5 KK3P-50N -60N -65N KK4P-50N -60N -65N -80N -85N KKH3S-50N -60N -65N KKH4S-50N -60N -65N -80N -85N 1/8 1/8 1/4 1/4 Use Series KK plug with Series KKH socket, as there is no plug available in Series KKH.
L M Effective orifice(mm 2) Applicable tube O.D.
The mounting nut is not included with the double clevis type.
Press the SET button continuously for 2 seconds or more. Setting is completed when the SET button is pressed continuously for 2 seconds or more. Setting is completed when the SET button is pressed continuously for 2 seconds or more. Setting is completed when the SET button is pressed continuously for 2 seconds or more. Enter the setting value.
Load voltage at OFF = = 24V 4V x 2 pcs. = 16V = 1mA x 2 pcs. x 3k = 6V Example: Power supply is 24V DC Switch internal voltage drop is 4V Example: Load impendence is 3k Leakage current from switch is 1mA 2.11-7 Series MHZ2, MHZJ2, MHK2, MHKL2, MHC2, MHT2 Installation and Setting of Auto Switch Auto switches can be used in various ways depending on the number installed and the required detecting
When needle valve is turned clockwise, it is closed and cylinder speed decreases. When needle valve is turned counter clockwise, it is open and cylinder speed increases. Screw Torque Caution qSuitable torque for tightening fittings is shown in the table below. For standard installation, turn 2 to 3 turns using tool after fastening by hand.
Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur . 2.
Green lights up when the power supply is ON. Green flashes if the power supply is abnormal. Red flashes if the CPU is abnormal. 2 Power supply indicator PWR LED (Green/Red) Green lights up when static neutralization is operated. Red lights up if incorrect high voltage is detected.
R and S (Because S function is also included in R.) S and T (Because S function is also included in T.) Note 2) Voltage symbol 20 (200 VAC) is the terminal block connection as standard. Option S cannot be chosen. Voltage symbol 10 (100 VAC) is the power cable with plug as standard.
8, @0, @1, @2, @3, @8 Set of left nos. !8, !9, @0, @1, @2, @3, @8 Note) !8 !9 @0 @1 @2 @3 24 Cylinder tube gasket NBR REAR10-PS 10 REAR10-PS Wear ring A Special resin 10: not available REAR15-PS 15 REAR15-PS Wear ring B Special resin Piston seal NBR Note 1) It may be difficult to replace the cushion seal @3. Note 2) For wear ring A of 10, please consult with SMC.
Note 2) The weight is the value for the grommet type. 2 Direct Operated 2 Port for Oil Series VCL Construction Parts list Description Material No.