/04w 2-1/4,3/8, 1/2 A,B PORTS L L 2-1/8 PILOT EXH PORTS 15 33.5 A A B B 29.5 29.5 5-1/4 PORTS M12 CONNECTOR (OPTIONAL) 2-7 MOUNTING HOLES 43.5 23 23 11.5 14 14 4 2 12 12 25 17 18 25 5 1 3 46.5 12 12 2-3/8 EA,EB PORTS 22.5 22.5 L = 1/4 23.5 15 30.5 45 3/8 27 EA EB P 1/2 30.5 49.5 1/4, 3/8,1/2 P PORT 152.5 165.5 ALL DIMENSIONS ARE IN MILLIMETERS 11 Series VS R8b S ISO SIZE 2-3 SUB-BASE VS8w

Refer to flow characteristic chart to select the model with adequate margin for required flow rate. 687 Compact Proportional Solenoid Valve Series PVQ10 How to Order 13 03 M5 5 PVQ L A Base mounted Body / Seal material Valve type / /! & !

Inch size Metric size 01 02 23 2 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 03 05 07 09 11 13 Control type 04 06 08 10 12 0 1 Meter-out Meter-in Use 1/8" tube.

Note) AS-FP Metric size Inch size Meter-out Meter-in 0 1 01 02 23 2 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 03 05 07 09 11 13 AS-FM 04 06 08 10 12 AS-D AS-T With One-touch fitting ASP Thread type M3 Port size Note) For applicable tubing O.D. selection, refer to the Model on page 484. Use 1/8" tube.

Thread type G adopts face seal method. 02 1/4 03 3/8 04 1/2 Only meter-in type is available. The meter-out version is not available and therefore is not shown in this How to Order. 10

Metric size Inch size Body size Port size 06 6 3 1/8 standard 07 1/4 Symbol Cylinder side 08 8 4 1/4 standard 09 5/16 01 R1/8 10 10 11 3/8 5 3/8 standard 02 R1/4 12 12 13 1/2 6 1/2 standard 03 R3/8 04 R1/2 N01 NPT1/8 N02 NPT1/4 N03 NPT3/8 N04 NPT1/2 XTO Series XTO257102 Applicable tubing O.D.

Thread type G adopts face seal method. 02 1/4 03 3/8 04 1/2 Only meter-in type is available. The meter-out version is not available and therefore is not shown in this How to Order. 10

Note) Type 01 02 03 04 Inch size Metric size Elbow Universal 2 3 1/8" AS 23 01 3.2 03 05 07 09 11 13 04 06 08 10 12 4 5/32" 6 3/16" Control AS-FE U10/32 N01 N02 N03 N04 8 1/4" Meter-out Meter-in 0 1 10 5/16" Made to Order Refer to the below for details. KE 12 3/8" 1/2" With One-touch fitting AS-FG Note) For applicable tubing O.D. selection, refer to the Model on page 734.

For Water Digital Flow Switch Series PF2W How to Order Integrated Display Type PF2W7 20 03 27 M Flow rate range Thread type 04 20 40 11 0.5 to 4 L/min 2 to 16 L/min 5 to 40 L/min 10 to 100 L/min Unit specifications Rc NPT G Nil N F With unit switching function Note1) Fixed SI unit Note2) Nil M Lead wire (Refer to page 322.)

Refer to pages 16-14-3 to 16-14-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 16-1-11 to 16-113 for Precautions on every series. q u w e 1 3 LOW i o r 2 4 Selection !0 t Caution !1 1. Select the model taking into consideration the material suitable for the operating fluid.

Inch sizes Metric 3, 4, 6 6, 8, 10 10, 12 19, 25 12, 19 03 05 07 11 13 19 25 1/8 3/16 1/4 3/8 1/2 3/4 1 Inch Valve type Symbol Type 1/4, 3/8 3/8, 1/2 3/4, 1 1/2, 3/4 1/8, 3/16, 1/4 Basic type N.C. PB PA PA N.O. PB B A B A B A Basic size With reducer Note) Applicable fittings for body class 6 is LQ1. N.C. N.O. Double acting Double acting With flow rate adjustment PA PA N.C.

Power Valve: Regulator Valve Series VEX1 How to Order 03 D 3 1 0 B VEX 1 Regulator valve Option None Nil Bracket Foot (VEX110 only) Gauge B F G When specifying more than one option, combine symbols alphabeticaly.

Double acting Double acting 03 04 06 08 10 12 19 25 3 4 6 8 10 12 19 25 With flow rate adjustment PA N.C. B A N.C. Double acting With bypass PA PA N.C. PB B A B A Inch sizes Double acting 03 05 07 11 13 19 25 1/8 3/16 1/4 3/8 1/2 3/4 1 N.C. Double acting N.C. With flow rate adjustment & bypass PA B A N.C. N.C. With indicator PA Basic size With reducer N.C.

Body Size/Type: 32 (Elbow Size 03 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: N (NPT), Port Size: 03 (3/8), Applicable Tubing O.D: 11 (ø3/8"), Sealant: S (w/Sealant)

Body Size/Type: 32 (Elbow Size 03 Standard), Control Type: 1 (Meter-in), 1: 1, Thread Type: N (NPT), Port Size: 03 (3/8), Applicable Tubing O.D: 11 (ø3/8"), Sealant: S (w/Sealant)

No.SYJ300-OMU0003 SYJ Series S 904 3.57 JIS C 3306 0.5mm L M DIN ) (Z) 22 3 0.4Nm (DZ) (1.652.5N m) () NL: () () (3 ) 1V (0.20.25Nm) DIN Y Y DIN DIN 8mm DIN D SY100-61-3-05 DDIN 9.4mm D DIN DC24V 24V SY100-61-3-05 N N DC12V 12V SY100-61-3-06 AC100V 100V SY100-61-2-01 D DIN Assy V115-D V115-Y AC200V 200V SY100-61-2-02 AC110V 110V SY100-61-2-03 V111(G,H,L,M,W)V115-Y

Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 http://www.smcworld.com 2012 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing QW printing QW 8150SZ Printed in Japan. D-G

OZ Edition B Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 URL http://www.smcworld.com 2010 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing NR printing OZ 7150SZ Printed in Japan. D-DN

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2"), VALVE FOR TRANSMISSION

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE