Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: ANB1-01, 55 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5
Controller Mounting: DIN Rail Mouting, Cable Length: 1 m, Inlet Port Silencer: AN10-01, 62 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5
Controller Mounting: DIN Rail Mouting, Cable Length: 1 m, Inlet Port Silencer: ANB1-01, 55 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5
Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: ANB1-01, 55 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: (None), Exhaust Solenoid Valve: V124-5LU-M5
Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: AN10-01, 62 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: -
s2 in X, Y, Z directions, 3 times each (De-energized)?
s2 in X, Y, Z directions, 3 times each (De-energized)?
y Return spring Stainless steel CAC406 u Body Dimensions: Bracket A J 4-G C 1.5 B D E L 4-H Valve mounting hole F Bracket Mounting Dimensions/Bracket Material: Stainless Steel (mm) A B C D E F G H J L Valve model Bracket part no.
Y DC: 0.45 W (With indicator light: 0.5 W) 24 VDC and 12 VDC are applicable to 0.45 W.
Terminal q DC (+) w N.C e DC () r IN (1 to 5 V) e w q Power supply/Output connection cable (Accessory) Power supply/Output connector (8P) Pin no. 7 Green 8 Yellow 6 Red 5 Gray 4 White 3 Black 2 Blue 1 Brown i u y t r e w q Pin no.
S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S B R G BU W Y YR N S PU BR GD GR T Black Red Green Blue White Yellow Orange Natural Silver Purple Brown Dk.
AFJ AFJ r t y u w AMV q Body size 20 30 40 ZH -X185 Symbol Description Related Products w Pipe thread type Nil Rc N NPT F G + 01 1/8 02 1/4 03 3/8 04 1/2 + e Port size Option a Mounting Nil Without mounting option r B Note 1) With bracket + b Element 5 5 m 40 40 m 80 80 m + Nominal filtration rating t c Water drop removal type/ Large flow type S Water drop removal type Type y T Large
(Select wiring bottom entry when the semi-standard Y is chosen simultaneously.) Note 4) The only difference from the standard specifications is the pressure regulator spring. It does not restrict the setting of 0.2 MPa/0.6 MPa or more.
AW30: G43-10-01-X3 or AW40: G43-10-02-X3 is included.
(Select wiring bottom entry when the semi-standard Y is chosen simultaneously.) Note 4) The only difference from the standard specifications is the pressure regulator spring. It does not restrict the setting of 0.2 MPa/0.6 MPa or more.
bowl with level gauge ACG20 With bowl guard Model combination ACG20 to 40 (9) Filter case with drain guide Combination ACG20 to 40 Non-relieving type Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge ACG20 to 40 Flow direction: Right Left Drain cock with barb fitting: 6 x 4 nylon tubing Symbol Air filter Lubricator Mist separator ACG30, 40 W ACG20 to 40 Y
(Select wiring bottom entry when the semi-standard Y is chosen simultaneously.) Note 4) The only difference from the standard specifications is the pressure regulator spring. It does not restrict the setting of 0.2 MPa/0.6 MPa or more.
s2 in X, Y, Z directions, 3 times each (De-energized)?
s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized