. / N.C.), Rated Voltage: 6 (12 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: Instantaneous Flow: L/min, Temperature:

H (Conduit terminal: T) I (DIN terminal: D) Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S T U Model VNA2-10A VNA2-15A VNA3-20A VNA4-25A 3 8 1 2 3 4 63 144.5 55 125.5 52 42 26 29 4.5 14 24.3 72.5 2.3 80.5 25 75 34 80 84.5 124 135.5 151.5 137 153 156 172 60.5 73 1 80 90 62 72 50 60 31 36 35 40 5.5 6.5 17.5 20 28.3 33.3 84 100 2.3 2.3 92 108 30 35 84 90 43 49 89 95 93.5 99.5 Port

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: E (Digital Pressure Switch for Vacuum / -100 to 100 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)],

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: 1 (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 06 (3/4), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G [Instantaneous Flow: L/min (gal/min), Temperature