N 0.5MPa 0.5MPa 40 40 0.4MPa 0.4MPa F 0.3MPa 0.3MPa 20 20 0.2MPa 0.2MPa 0 0 10 10 20 20 30 30 40 40 Gripping point L mm Gripping point L mm MHS2-25D MHS2-25D 100 100 F Internal gripping Pressure 0.6MPa Pressure 0.6MPa 80 80 Gripping force N Gripping force N 0.5MPa 0.5MPa 60 60 Note: 1N = 0.2248lbf 1in = 25.4mm 1MPa = 145psi 0.4MPa 0.4MPa 40 40 0.3MPa 0.3MPa 0.2MPa 0.2MPa 20 20 0 0 10 10
Applicable stroke table Stroke [mm] Size 30 50 100 150 200 250 300 350 400 450 500 Manufacturable stroke range 25 15 to 400 32 20 to 500 25 - .
13 40 12 17 58 11 47.3 61 M8 x 1.25 7 18 11 M18 x 1.5 19 30 17 90 2.5 25 159 3/8 up to 600 35 32 85 27 64 20 15.5 40 10 17 58 11 54.8 68.5 M10 x 1.25 7 18 14 M18 x 1.5 19 31 17 98 4 25 170 3/8 up to 750 40 37 32 78 25 52 14 21 71 13 65.8 M12 x 1.75 11 22 17 M22 x 1.5 23 37 21 4 40 204 102 18.5 80.5 116 1/2 up to 750 40 37 116 41 92 30 20 52 14 21 72 16 72.8 87.5 M12 x 1.75 11 26 17 M26 x
The proper tightening torque for screws 0.3 to 0.4 Nm Rated voltage With indicator light VZ Voltage symbol Part no. 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC 24V 12V 100V 200V 110V 220V AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 VS (b) VFN Valve Mounting Circuit with Indicator Light After confirming the gasket is correctly placed under the
AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 Valve Mounting VS After confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque listed below.
14 4 41 AC40-B 1/8 220.4 147.1 39.8 38.4 72.6 110 33.8 3.5 50 75.2 40 9 18 5 48 1/43/81/2 AC40-06-B 1/8 235.4 149.1 37.8 38.4 77.6 110 33.8 3 50 80.2 40 9 18 5 48 3/4 AC50-B 1/8 282.4 220.1 41.2 93.1 110 43.3 3.2 70 96.2 50 11 20 6 60 3/41 AC55-B 1/8 292.4 234.1 44.7 98.1 110 43.3 3.2 70 96.2 50 11 20 6 60 1 1 AC60-B 1/8 297.4 234.1 44.7 98.1 110 43.3 3.2 70 101.2 50 11 20 6 60 Optional
Output impedance Approx. 1 k Analogue output 2.4 to 20 mA 3.2 to 20 mA 4 to 20 mA 2.5% F.S. 2.5% F.S. 2.5%F.S. Output current Current output 3 Linearity: 1% F.S. Linearity: 1% F.S. Linearity: 1% F.S.
Fittings & Tubing Air Cylinders Rotary Actuators Relief port 2 x M5 x 0.8 2 x P through M5 x 0.8 R GC GB E GA MM D C J 2.8 2 x P through A 4 x T counterbore E 0.5 B H S Z (mm) 6 depth 4.8 5 S 10 15 20 25 30 5 Z 10 15 20 25 30 Bore size B C D E GA GB GC H J MM P R T A 13 22 3 23 16 15 13 10 3.2 7 M3 x 0.5 31 10 7 6 10 15 24 4 24 33.5 16 15.5 16 11 M4 x 0.7 3.2 9 6 depth 5 64 69 74 79 84 89
(Max. 20 stations) SUP/EXH block assembly mounting position Valve stations Series 3 5 7 02 2 stations SY3000 SY5000 SY7000 20 20 stations Symbol Mounting position U side D side Both sides Special specifications Applicable stations U D B M 2 to 10 stations 2 to 20 stations In case of special specifications, indicate separately on a manifold specification sheet.
110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 1/8, 1/4, 3/8 1/4, 3/8 1/2 3/8, 1/2 3/4 1/2, 3/4 1 3/4, 1 1, 11/2 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 24
(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED display LED display to indicate the status of the SI unit. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.
OFF M3 hexagon screw Tightening torque 0.6 Nm 1 2 0 0 0 IP address 192.168. Y . X : Thread size: M3 x 30 The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result.
Ambient temperature for operation: -10 to 50 oC Ambient temperature for storage: -20 to 60 oC Model number GSD file M3 hexagon screw If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident. 1 EX260-SPN1/SPN2 GSDML-V.
Solenoid on side B 1 3 5 7 9 17 29 31 No. Designation Description 1 3 5 7 1 1 5 7 Bit No.
M3 hexagon screw Tightening torque 0.6 Nm Terminating resistor Valve manifold : Thread size: M3 x 30 Troubleshooting The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result.
with Rod Boot M14X1.5 M 1 8 X 1 . 5 M18X1.5 M22X1.5 t\,126X1.5 242 ' , u ' 2 O 27 /a 42 20 10 153 I 234 244 43 1.2 59 % 1 6 30 46 1 0 21 50 12 168 1 9 0 104 'r u:3j 38 261 273 52 1.2 66 269 1t4 31 ,s 48.5 23 60 '16 182 23 0 49 58 290 296 52 1.2 66 2Aa 37 ', 55 23 70 20 2Ca 2A 0 7 1 327 347 65 12.5 80 336 40 56.5 25 80 25 226 36 0 72 241 65 1 4 . 0 81 365 Trunnion Type/CLAT with Rod Boot M14X1.5
with Rod Boot M14X1.5 M 1 8 X 1 . 5 M18X1.5 M22X1.5 t\,126X1.5 242 ' , u ' 2 O 27 /a 42 20 10 153 I 234 244 43 1.2 59 % 1 6 30 46 1 0 21 50 12 168 1 9 0 104 'r u:3j 38 261 273 52 1.2 66 269 1t4 31 ,s 48.5 23 60 '16 182 23 0 49 58 290 296 52 1.2 66 2Aa 37 ', 55 23 70 20 2Ca 2A 0 7 1 327 347 65 12.5 80 336 40 56.5 25 80 25 226 36 0 72 241 65 1 4 . 0 81 365 Trunnion Type/CLAT with Rod Boot
A 47 58 B 35 40.5 QA 6 8 QB 13 16 QV 33 38.5 Bore size (mm) 40 50 20 Series RSG Rod End Configuration Lever Type with Integrated Shock Absorber Basic type/Flange mounting These drawings (2 items) show the piston rod extended. Direction of work piece conveyance RSG-L Bore size: 40, 50 (98 + Stroke) Stroke 20 A 4-9 through 110 + Stroke 177 + 2 Strokes 67 + Stroke Approx.
View A PFA3-B DIN rail type Sensor Blue Brown Black Analog output 1 2 3 4 3 x 7.2 (= 21.6) 8-M3 36 15 6.4 2 3.4 5 6 7 8 OUT1 N.C. Load Load 2 1 3 4 6.5 12 to 24VDC + 26 SMC FLOW SWITCH PFA312-(-M) 35.5 30 15.2 56 (4.5) 44 UNIT RESET SET Sensor Blue Brown Black Analog output 1 2 3 4 5 6 7 8 5 6 7 8 29 OUT1 N.C.
Keep the air flow within the rated flow to prevent an outflow of lubricant to the outlet side Note2 When compressor oil mist discharge concentration is 30mg/m3 (ANR). Note3 Bowl seal and other O-rings are slightly lubricated.