OFF OFF 1 ON OFF 2 Binary Output OFF ON 3 ON ON 4 31 point preset output is possible without bank switching, by means of binary system output from a 5 point output terminal. Cylinder stop output is used as the readout release signal. 31 30 4 When the count value coincides with preset no. 3. 3 2 1 Preset no.
M3 x 0.5 Finger opening port 4 0.005 0.025 1.6 7 M3 x 0.5 Finger closing port 18 In the case of MHC2-6S, finger opening port is a breathing hole. 8 Series MHC2-6/MHCA2-6 Dimensions MHCA2-6 (Short body) 2-M2 x 0.4 thread depth 4 (Mounting thread) 4-M2 x 0.4 through (Attachment mounting thread) 5 10 Attachment mounting limiting range 16 11 2-M3 x 0.5 through Prepared hole dia. 2.6 through
screw) 31 0.5 45 45 3 3 5.3 5.3 250.2 250.2 32 16 2 x M3 x 0.5 through 6.5 counterbore depth 5 (Same on the opposite side) 3.4 through 3 3 45 5.5 45 M2.5 x 0.45 x 6 L (Hexagon socket head cap screw) M3 x 0.5 x 12.5 L (Hexagon bolt) and M3 x 0.5 (Hexagon nut) 2 x M3 x 0.5 through Steel ball Plug 2 x M3 x 0.5 through 2.75 (11) (10+ST) 250.2 4 Part no.
ZZ Max. 31 2 x 6H7 Depth 8 4 x 9.5 counterbore depth 5.5 With shock absorber Max.
Model Screw size Max. tightening torque [Nm] A [mm] L [mm] EQFS16 M3 0.6 3.5 23.5 EQFS25 M4 1.5 4.5 24 EQFS32 M5 3.0 5.5 30 EQFS40 M6 5.2 6.6 31 Body mounting Maintenance Warning Body mounting reference plane For housing B bottom Maintenance frequency Positioning pin (Reference plane) Perform maintenance according to the table below.
ZZ Max. 31 2 x 6H7 Depth 8 4 x 9.5 counterbore depth 5.5 With shock absorber Max.
ZS-28-B) M3 x 5L 2. Mounting with panel mount adapter Secure the panel mount adapter with two M3 x 8L mounting screws. Panel Front protective cover (Part no. ZS-27-01) M3 x 8L 2. Connector pin numbers for power supply/output cable Panel mount adapter (Part no. ZS-27-C) Rotate 90 to mount. 16-3-30 9 Series PSE Specific Product Precautions 3 Be sure to read before handling.
(Mounting angle adjustable range) Pivoting bracketIZN10-B2 (Mounting angle adjustable range) 2 x Hexagon socket head cap screw M3 x 16 (Accessory) 30 Doc. no.IZ-OMV0005 DIN rail mounting bracketIZN10-B3 (Mounting angle adjustable range) 40o 2 x Hexagon socket head cap screw M3 x 6 (Accessory) Pivot mounting Inward mounting (Mounting angle adjustable range) 31 Doc. no.IZ-OMV0005 Power supply
mounting nut Hexagon socket head cap bolt (M3 x 0.5 x 14 spring wasdher 2 pcs.)
x 0.5 MXS 3H9 +0.025 0 depth 3 Note) F (Equal pitch) N x M3 x 0.5 thread depth 6.5 (Insert) 6 A 4 4.7 MXQ 48 6 10.5 35 MXF 14 21 31 20.5 MXW 13 18 3H9 depth 3 +0.025 0 3H9 depth 3 +0.025 0 58 MXJ 4 x 3.2 4 x 6.5 15 9.5 MXP MXY 4.5 4.7 2 x M3 x 0.5 thread depth 6 A G H 4 x M4 x 0.7 8 MTS Section AA Operating port 2 x M3 x 0.5 M 8 N 2 ( 1): The number of pitches 0.3 15 (Table length) 16
Match polarity between solenoid valve and SI unit output. -41No.EX-OMX1001 Maintenance Replacement of the SI unit Remove the M3 hexagon screws from the SI unit and release the SI unit from the valve manifold. Replace the SI unit.
The terminal screw is an M3 cross head screw. Note: Connect the ground terminal to ground. Resistance to ground should be 100 ohms or less. A. Single power supply used B.
Applied voltage When connecting fittings to valves, tighten as indicated below. 1) M3, M5 types 1. When using SMC fitting, follow the guidelines below. After tightening by hand, tighten an additional 1/4 (M3), 1/6 (M5) turn with a tightening tool. However, if miniature fittings are used, tighten an additional 1/4 turn with a tightening tool after tightening by hand.
Class B coil: AWG20 Insulator O.D. 2.5 mm Terminal cover Round head combination screw M3 Tightening torque: 0.5 to 0.6 Nm mark mark Tightening torque: 0.5 to 0.6Nm Round head combination screw M3 Tightening torque: 0.5 to 0.6Nm Conduit terminal Cross section A-A (Wiring inside) Lead wire Seal Conduit piping (Port size G1/2 Tightening torque 0.5 to 0.6Nm) Rated voltage Lead wire color (1)
Manually unlocking For 20 to 32 Dust cover holding bolt Dust cover Manual unlocking bolt Manual unlocking bolt Lock ring Locking direction Locking direction Lock ring Rod side Head side Rod side Head side MLGP--F: Extension locking MLGP--B: Retraction locking 1) Remove the dust cover. 2) Screw a manual unlocking bolt (a bolt of M3 x 0.5 x 15L of more commercially available) into the lock
X 0.5 M10 X 1.0 9 18.5 25.5 32.5 3 27.5 34.5 41.5 3 10 19 22 6 14.5 21 28 12 12 3.5 M4 X 0.7 M15 X 1.5 13 20.5 27 34 4 32.5 39 46 5 12 27 31 7 16.5 22.5 29 19 14 4.2 M5 X 0.8 M22 X 1.5 20 23.5 29.5 36 5 37.5 43.5 50 6 Plug Mounting Style CJPS B C E G H K MM NN 5st 10st F 15st R 5st 10st S 15st W Q 5st 10st Z Bore (mm) 6 10 15 A 15st 7 12 13.9 6 12.5 19.5 26.5 8.5 9 3.5 M3 X 0.5 M10 X 1.0
x 0.5 (attachment mounting screw ) M5 x 0.8 Finger closing port 0 -0.1 8 0 -0.7 14.9 closed 4 7 4-M5 x 0.8 depth 8 (two on opposite side) 18.8 15 Max. 7.3 42 22.5 M5 x 0.8 Finger opening port 3-R2 3 29 15 16 10 22 8 31 18 51.5 6 40 78 Angle adjustment bolt 2-5.5 through 2-9.5 depth of counter bore 3 3-R2 11 2 10 +0.03 0 3-4H9 long groove depth 4 (one each on three sides) 0 -0.062 47h9 M5
9 Magnet Nickel plated @0 Hexagon socket head set screw Stainless steel @1 Resin case Resin @2 725 Series MRHQ Dimensions MRHQ10 A B 34 41 54.5 4 x M4 x 0.7 depth 6 24.5 0 -0.062 37h9 0 -0.1 4 31 +2.2 0 15.2 opened 0 -0.1 5 0 -0.7 11.2 closed M5 x 0.8 4 x M2.5 x 0.45 (attachment mounting screw ) Finger closing port 3 Max. 6.1 5.7 13.7 12 4 x M4 x 0.7 depth 6 (two on opposite side) 34 M5 x
Terminal cover 2(, +) 2(, +) Round head combination screw M3 Tightening torque 0.5 to 0.6 Nm A Without electrical option With surge voltage suppressor DIN terminal, Conduit terminal 2 1 + mark +mark Varistor A 1(+, ) G1/2 Tightening torque 0.5 to 0.6 Nm SOL.
External pilot port Without M5 x 0.8 thread: Internal pilot VVEXB-1 With M5 x 0.8 thread: Common external pilot VVEXB-2 P = 31 P(1) port: Rc 1/8, For 6 manifold stations or n-Rc 1 8 more, exhaust from the both sides.