VNA VNA 2 1 2 1 2 1 VNA VNA D-X Technical Data 1177
Signal Cable color S Standard cable Brown Red Orange Yellow Green Blue A A B B COM-A/COM COM-B/ 2 1 6 5 3 4 Cable color Connector D terminal no.
8 9 A B C D E F 1 4.1 + *S2 S1 DC24V MADE IN JAPAN 2 3 4 (48.5) (50) 133 10.5 10.5 5.1 4.5 5 5 Models Output unit can be used for mixed connection with PCW series.
Component Parts Note No. q Description Material Plated Cast iron Cover assembly Body assembly Platinum silver painted Valve composition, NBR, FKM Aluminum alloy Iron N.O.
When used as a switch output device Setting of NPN open collector 2 outputs Setting of PNP open collector 2 outputs Brown DC(+) q Brown DC(+) q Load Black OUT1 r Black OUT1 r Load Main circuit Main circuit + + 12 to 24 VDC 12 to 24 VDC White OUT2 w White OUT2 w Load Load Blue DC() e Blue DC() e When used as an IO-Link device Brown L+ q L+ Black C/Q r Main circuit C/Q IO-Link master White
DC+ 1 Brown q N.C. 2 Not used w DC 3 Blue e IN: 1 to 5 V 4 White r Power supply/Output connector (8P) Power supply/Output connector (accessory) i u y t r e w q Pin No. Pin no. Terminal 7 Green CH4_OUT1 8 Yellow N.C.
Lube Unit/ALDU600-06 to 10, ALDU900-12 to 20 Float switch mounting position Mounting thread M12 R 3.2 S 40 Q IN P M N M L A B C E E F G K J (Bracket mounting dimensions) H D S Bracket (Option) Panel (Option) 6 x 17 A B C D E F G H J K L M N P Q R S Model Port size ALDU600-06 ALDU600-10 ALDU900-12 ALDU900-14 ALDU900-20 289 291.2 453 453 476 24.5 13.6 51 45.5 14.5 69.5 78.2 89 94.5 102.5 4
Aluminum die-casted Aluminum die-casted Material Note q Description Housing Body Chrome treated Epoxy coating on inner surface Note: Sight glass is indicated in the figure above for easy understanding of parts, however mounting position is different. Refer to dimensions on pages 14-20-40 to 14-20-41 for details. w e Sight glass Tempered glass AM850 is aluminum casted.
This is not a clean room series product. 4 MACM Series Dimensions W (Workpiece loadable range) 4 x D At maximum offset (A + 2 x S) S F DB DA C X114 X115, X116 U B W A H T H Q PB E PA PD P (Unlocking port) PE P (Locking port) P (Relief port) (Option V only) MACM4, MACM6 MACM2, MACM10 PC PC PC PC PE P (Relief port) (Option V only) PD [mm] Dimensions Model A B C D DA DB E F H P PA PB PC PD
Description TBR-1,2,3,4 TBR-A167 q Side plate PP TBR-1 TBR-A188 TBR-2 TBR-A168 w Branch pipe ABS TBR-3 TBR-A169 TBR-4 TBR-A170 TBR-1 TBR-A183 TBR-2 TBR-A184 e Fixing rod ABS TBR-3 TBR-A185 TBR-4 TBR-A186 TBR-1,2,3,4 TBR-A187 r Fixing plate PP 534
Actuating force F1 is applied to the top surface of pressure regulation piston r by the pilot pressure (pilot valve assembly q: VY1D B 00-00), and actuating force F2 is applied to the bottom surface of the piston by the port A pressure that pases through the feedback passage. Thus, the port A pressure that corresponds to the pilot pressure is established.
Size ASF Model d T Weight (g) H D1 D2 L1 L2 L3 L4 A Model d T Weight (g) H D1 D2 L1 L2 L3 L4 A Max.
N R Pilot port 12(P1) Indicator (Option) 1 8 2 x (Back side 10(P2)) VNA P1 4 x P S VNB F U D E SGC Bracket (Option) A B 15 SGH VNC 1(A) (Back side 2(B)) Main port T C Port size: refer to table below A B VNH VND VND Main port 1(A), 2(B) A B C D E F G M N P Q R S T U Model VCC VND20D-10A VND20D-15A VND30D-20A VND40D-25A 3 8 1 2 3 4 1 63 42 28 14 73.5 81.5 4 52 26 4.5 24.3 2.3 25 34 56 TQ 80
PF3A702H AC40#-D Y400-D Y400T-D E400-#04-D : For more information about the options, refer to our website (URL https://www.smcworld.com). 4 Snap shot function The current flow rate value can be stored to the switch output ON/OFF set point.
PF3A802H AC40#-D Y400-D Y400T-D E400-#04-D 4 : For more information about the options, refer to our website (URL https://www.smcworld.com).
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-11 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-O021 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
Note 5) 3/16", 3/8", 1/2"are made of brass AS131F (3.2, 4, 6, 1/8", 5/32, 1/4), AS231F-01(3.2, 4, 6, 1/8", 5/32) are POM. 15-9-5 5 Series AS Elbow Type M3 port M5 port U10/32 port Applicable tubing O.D. d (Hexagon width across flats) Applicable tubing O.D. d (Hexagon width across flats) Metric Size Inch Size Applicable tubing O.D. d 1/8" Applicable tubing O.D. d A(2) Weight (g) T D1 H(1)
ZA A B t 2 x D ZX C ZM ZL ZH ZH ZH ZH -X267 ZH13 to 20DA 2 x D B ZHP A F E C ZU VQD-V Long clamping screw set for 1 station required for assembly needs to be ordered separately.
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Fig. 3-11 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-W038 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly. Incorrect piping might cause leakage of supplied or drained leakage and wet surrounding area and facility.
D) Exhaust the air while in the clamped state, and confirm that the clamp arm does not open. 7
Setup Procedure CKZT -X2797 -X2798 Power clamp cylinder mounting and setup procedure