TF G 1/8 G 1/8 G 1/8 G 1/4 G 1/4 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 NPT 1/4 NPT 1/4 Nil M3 x 0.5 M5 x 0.8 M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 Rc 1/4 CY3B6 CY3B10 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 CY3B50 CY3B63 25 30 35 50 50 50 60 60 70 10 16 19 25 30 40 40 60 70 16 16 78 81 103 132 137 156 182 180 192 d CYP C H B H 4 4 8 8 10 B 8 14 26 32 41 C 9.2 16.2 30 37 47.3 d M6 x 1.0
Single vane type/Double vane type CRBU2W40-S/D
Made to Order (For details, refer to pages 16 to 21.)
Refer to "Operation at low ambient temperature or low circulating fluid temperature" (page 186-1) for the concentration of the ethylene glycol aqueous solution. 4 h 2 h 1 h 5.
FU) (mm) AA AB A AV AW AX AY BA BB BC BD BE CB D DD DE DF DG FA FB FC FD H J JA JB Size 70 100 200 90 92 84 42 25.5 27 8 17 75 44.5 110 57 36 88h9 90h9 46H9 16 22H9 12.5 5 3.5 9 22 10.4 17.5 10.5 100h9 101 102 95 50 29.5 27 8 17 85 50.5 130 66 42 98h9 56H9 19 24H9 14.5 6 3.5 12 27 10.4 17.5 10.5 116h9 118h9 119 120 113 60 36.5 36 10 24 103 65.5 150 80 57 64H9 24 32H9 16.5 9 5.5 15 32 14.2
Set the switch to either H (High), M (Middle), L (Low). At settings other than these, the ionizer does not perform the emitter stain-detection. H (High) Level that does not affect the discharge time. M (Middle) Level at which the discharge time is a little bit longer than it was initially. Settings with the same letter share the same level.
Gripping Point Range Limit 8MHK2-12 MHKL2-12 MHK2-16 MHKL2-16 MHK2-20 MHKL2-20 MHK2-25 MHKL2-25 Overhang distance H (mm) Overhang distance H (mm) Overhang distance H (mm) Overhang distance H (mm) 60 60 100 120 Pressure 0.2 MPa 50 50 100 Pressure 0.2 MPa Pressure 0.2 MPa Pressure 0.2 MPa 80 40 40 80 60 0.3 MPa 0.4 MPa 0.5 MPa 0.6 MPa 0.3 MPa 0.4 MPa 0.5 MPa 0.3 MPa 0.4 MPa 0.5 MPa 0.6 MPa
Gripping Point Range Limit 8MHK2-12 MHKL2-12 MHK2-16 MHKL2-16 MHK2-20 MHKL2-20 MHK2-25 MHKL2-25 Overhang distance H (mm) Overhang distance H (mm) Overhang distance H (mm) Overhang distance H (mm) 120 60 60 100 Pressure 0.2 MPa 100 50 50 Pressure 0.2 MPa Pressure 0.2 MPa Pressure 0.2 MPa 80 40 40 80 60 0.3 MPa 0.4 MPa 0.5 MPa 0.6 MPa 0.3 MPa 0.4 MPa 0.5 MPa 0.3 MPa 0.4 MPa 0.5 MPa 0.6 MPa
A S G D L TG effective depth TL TF effective depth TL TD TB TC (mm) D (g6) DD (h9) AU A B BA BB BC BD BE BU F H J JA JB JJ K Size Rotation angle 20 30 40 90, 180 50 25 2.5 63 (11) 14 34 14.5 30.4 10 30 M8 x 1.25 11 6.5 3 90, 180 M5 x 0.8 depth 6 68 30 3 69 (11) 14 39 16.5 49 16 34.7 12 32 M10 x 1.5 14 8.5 4 90, 180 M6 x 1 depth 7 76 32 3 78 (13) 16 47 18.5 55 16 40.4 15 36 M10 x 1.5 14
AS131FM(3/16"), AS231FM(3/16", 3/8") is brass. !3 !2 q o !4 !7 !5 15-9-59 4 Series AS-FM Dimensions: Elbow Type M5 type U10/32 type Applicable tubing O.D. d Applicable tubing O.D. d H H (Hexagon width across flats) (Hexagon width across flats) A L4 A D1 L4 D1 L3 L3 M1 M1 T D2 L1 D2 L1 T L2 L2 Metric Size A L4 Weight (g) d T Model M1 D2 L2 L3 D1 L1 H Min. Min. Max. Max.
Refer to LECYU Operation Manual, Section 4 and Section 5 and Section 10 for details. 6.1 The recommended value of the parameter [LEF] LEFS25 LEFS32 LEFS40 Series Lead symbol H A B H A B H A B Lead 20 12 6 24 16 8 30 20 10 Initial value Recommended value Parameter *1,*2 Para.
No.SFOD-OMT0009CN-B LEFS40 H A B [mm] 30 20 10 [mm] 1200 1000 1100 1200 1000 1100 1200 [mm/s] 500 500 410 340 250 200 170 [mm/s] 30 20 10 () [mm/s] 49 33 17 () 1.3 LES(H) LES(H)8 LES(H)16 LES(H)25 J K J K J K [mm] 8 4 10 5 16 8 [mm/s] 400 200 400 200 400 200 [mm/s] 20 10 20 10 20 10 () [mm/s] 25 13 27 14 30 15 () 1.4 LEP LEP*8 LEP*16 J K J K [mm] 8 4 10 5 [mm] 25 25 [mm/s] 300 250
G H Model A ZH18DS-12-03-12 ZH18DL-12-03-12 ZH20DS-12-04-16 ZH20DL-12-04-16 12 12 12 12 110 52.45 42 15.8 3.5 19 20.95 110 52.45 42 15.8 3.5 19 20.95 124.6 60.95 47.7 15.8 3.5 24 26.75 124.6 60.95 47.7 15.8 3.5 24 26.75 I J K L M N O Model 3 8 Rc3 8 Rc1 2 Rc1 2 ZH18DS-12-03-12 ZH18DL-12-03-12 ZH20DS-12-04-16 ZH20DL-12-04-16 Rc 12 12 16 16 15.8 35.5 50 17 10 15.8 35.5 50 10 17.2 38.5 54.3
0.17 in. 4.4 mn o.T. 0.0E an. l.0mm) T T O.25 in. (6.4 mm) '75 PSIG (5 Kgflcm2) A E c D E F G H K M N P H 5.O7 (128 9) 4.39 (1 1 1.4) 1 1 8 (30) 1 6 9 t 7 5 '| _5 | 1 " (3) 080 20.4 1 5 7 a{I)l o71 alA) 0 9 6 24 S\ '1.26 (321 1 4 2 t36l 1 2 0 'io 5 ,2/ (6) Millimelsrs in Pargntheses Series NVM MECHANICALLY ACTUATED/PILOT OPERATED DIMENSIONS NVZM45O N\ZM45o-N014 A ts D E F I H J K M N P H
Conversion factor: kcal/h to kW : 860 [(cal/h)/W] * Refer to the following for the typical physical property values by circulating fluid.
H F O.F. 5 07 tbs. {2.3 t\ol T T . 90" 5 7 4 (145 9) 452 1 1 4 9 ) t t 8 t30l 1 2 2 {3t } 0 0 6 (1 s) l 1 ?
Inch Threads Bore size (mm) Bore size (mm) 12 16 20 25 Dd9 (inch) l d d H B C Part No.
1100 1200 1000 1100 1200 mm/s 500 500 410 340 250 200 170 [mm/s] () 30 20 10 [mm/s] () 49 33 17 1.3 LES(H) LES(H)8 LES(H)16 LES(H)25 J K J K J K [mm] 8 4 10 5 16 8 mm/s 400 200 400 200 400 200 [mm/s] () 20 10 20 10 20 10 [mm/s] () 25 13 27 14 30 15 1.4 LEP LEP*8 LEP*16 J K J K [mm] 8 4 10 5 [mm] 25 25 mm/s 300 250 150 350 250 200 [mm/s] () 20 10 20 10 [mm/s] () 25 13 27 14 -109No.JXC-OMT0001CN-C
Q+Stroke (NA) Cylinder form 12 16 (mm) d Bore size (mm) Standard stroke (mm) A B C E G GP H HA HG HN HP HT J JK L LD Slide Ball bushing 12 15, 25 8 4 16 25 7.5 50 34 6 14.5 34 33 18 M5 X 0.8 9.5 68 4.3 8.5 10 16 15, 25 9.5 5 18 29 6.5 65 40 6.5 16 39.5 39 21 M6 X 1 9.5 75 5.2 7.5 12 20 25, 50 11 6.5 25 36 8.5 80 46 9 18 44.1 45 24 M8 X 1.25 10 86 6.9 9.5 16 25 25, 50 11 6.5 25 40 8.5 90 54
of read outputs: 16 bits (10h) 12 1 (Number of bits) 13 0 Calculated 14 value Checksum(LRC) 15 Calculated value 16 End code CR 17 LF Note 1: The maximum value is 456 bits.