SMC Corporation of America
Elite Part Number Search
Search Results "LEY32RC-50C-S3AN3D"

Cylinder side pressure (P2) I N I N O UT O UT Specifications 0.8 MPa 0.15 MPa 5 to 50C 0.60 dm3/(sbar) 180 c.p.m Maximum operating pressure Minimum operating pressure Ambient and fluid temp.

Repeatability Note 4) 2% F.S. (0 to 50C, based on 25C) Temperature characteristics For measured value display: 4-digits, 7-segment LED (Orange) For channel display: 1-digit, 7-segment LED (Red) Display method Status LEDs Illuminates when output is ON OUT1: Red Enclosure Operating temperature range Operating humidity range IP65 for the front face only, the rest is IP40.

Status LEDs 24 VDC 10% Power supply voltage Current consumption 35 mA or less Enclosure IP40 0 to 50C (with no freezing and condensation) Operating fluid temperature Operating: 0 to 50C Stored: 10 to 60C (with no freezing and condensation) Operating temperature range Operating humidity range Operating, Stored: 35 to 85%R.H.

Operating: 0 to 50C, Stored: 10 to 60C (with no freezing and condensation) Resistance Operating or Stored: 35 to 85%RH (with no condensation) 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs., whichever is smaller.

Recommended lubricant [AL] Class 1 turbine oil (ISO VG32) Bowl material [AW/AL] Polycarbonate Bowl guard [AW/AL] Semi-standard (Steel) Standard (Polycarbonate) Construction [AW] Relieving type Weight [kg] 0.33 0.63 1.15 1.25 3.21 3.36 1 Pressure gauge connection threads are not available for F.R.L. unit with a square embedded type pressure gauge or with a digital pressure switch. 2 5 to 50C

. *2 5 to 50C for the products with the digital pressure switch *3 For the following conditions in accordance with [Test condition: ISO 8573-4:2001 compliant, Test method ISO 12500-3:2009 compliant] Conditions: When a new element is used, and the flow capacity, inlet pressure, and the amount of solid bodies on the filter inlet side are stable *4 The compressed air purity class is indicated

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, GC, 16MM LE ELECTRIC ACTUATOR, 1.46607 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 11.21006 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 6.61386 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 13.55842 lb

The LES series electric slide table actuator uses a compactly-integrated, recirculating linear guide for high rigidity and high precision. When the LES is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein.. Two types of built-in motors * are available. The series can be top or bottom mounted. In

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, GC, 16MM LE ELECTRIC ACTUATOR, 4.89478 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, EC, 10MM LE ELECTRIC ACTUATOR, 5.40132 lb

5 to 50C 5 to 50C 5 to 50C 5 to 50C 5 to 40C 5 to 40C 5 to 40C 5 to 40C Electric power 180VA 300VA 300VA 300VA 640VA 180VA 300VA 640VA 180VA 300VA 640VA 640VA Control system AC software servo/PTP control Position detection system Incremental encoder Home position return direction Maximum positioning point setting Can be selected between the motor side and the side opposite the motor. 1008

Note 3) Solenoid valve: Max. 50C Note 4) Synthesized effective area with 2 position.

: based on 25C) 2% F .S. or less (0 to 50C: based on 25C) 5% F.S. or less (0 to 60C) ZSE30: 0.2 F.S. 2 digits or less ISE30: 0.2 F.S. 1 digit or less Repeatability 1% F.S. or less 0.2% F.S. 1 digit or less 0.5% F.S. 0.2% F.S. 1 digit or less Hysteresis mode: Variable Window comparator mode: Variable Hysteresis mode: Variable Window comparator mode: Variable Variable 1 to 10% Fixed 3% F.S.

For models with a solenoid valve, the temperature of the solenoid valve section should be no greater than 50C. All models 1. When controlling valve responsiveness, take note of the size and length of piping, as well as the Cv factor (flow rate characteristics) of the actuating solenoid valve.

The compatibility is indicated for fluid temperatures specified for the respective products (50C or less). 7. Do not use liquids that will cause the wetted sealant to swell.

Flow characteristics: C Max. operating frequency 0.8 MPa 0.15 MPa 5 to 50C 0.60 dm3/(sbar) 180 c.p.m SUP side pressure (P1) To CYL port VVQ1000-FPG-02 1 set VQ1000-FPG-C6M5-D 2 pcs.

ZX1-F Operating pressure range Operating temperature range Filtration efficiency Element Mass Standard accessory Vacuum to 0.5 MPa 5 to 50C 30 m PVF 35 g Bracket A (ZX1-OBA) Note) If not operated within the specified range of pressure and temperature, trouble may result.