How to Order Integrated Display Type PF2A7 10 01 27 Flow rate range Thread type Unit specification 1 to 10l/min 5 to 50l/min 10 to 100l/min 20 to 200l/min 50 to 500l/min 10 50 11 21 51 Nil M Wiring specification With unit switching function Fixed SI unit Note) Nil N F Rc NPT G 3m lead wire with connector Without lead wire Nil N Note) Fixed units: Real-time flow rate: l/min Accumulated flow
-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Vacuum switch unit E C ZX1 1 10 Ejector unit Filter unit F ZX1 1 10 Ejector unit PV/V port size Ejector unit nozzle dia.
How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)
How to Order Hexagon Socket Head Cap Screw ZQSTB 05 Fitting assembly Number of stations Clip (ZK1-CP-A) 10 pcs. in one set 01 02 1 station 2 stations Applicable tubing O.D.
-020 BMA2-025 BMA2-032 BMA2-040 9 8 10 10 9 8 10 10 14 13 13 14 D-B5/B64 D-B59W D-G5/K59 D-G5W/K59W D-G5BAL D-G59F D-G5NTL D-G5NBL 9 8 10 10 4.5 4 4 5 BA-01 BA-02 BA-32 BA-04 D-H7C 9 7 8.5 10 D-G5/K59 D-G5W/K59W D-G5NTL/G5BAL 4.5 4 4 5 D-B7/B80 D-B73C/B80C D-G79/K79 D-K79C D-G59F D-G5NBL BM1-01 BM1-02 BM1-32 BM1-04 5.5 5 5 6 40 40 35 45 Since this is a guideline including hysteresis, not
Alarm1 Water Leak Detect FLT 01 Alarm2*1 02 Alarm3 RFGT High Press FLT 03 Alarm4*1 04 Alarm5 Reservoir Low Level FLT 05 Alarm6 Reservoir Low Level WRN 06 Alarm7 Reservoir High Level WRN 07 Alarm8 Temp. Fuse Cutout FLT 08 Alarm9 Reservoir High Temp. FLT 09 Alarm10*1 10 Alarm11 Reservoir High Temp.
Example) For 10-CQSXB25-47D, a 3mm spacer is installed inside a standard stroke 10-CQSXB25-50D cylinder.
They can be ordered in lots of 10 pieces. d D Series SY3000 SY5000 SY7000 Part No.
AS2052F-A AS1002F-A AS2002F-A 500 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 01, 23, 03, 04, 06, 07 100 08, 09 06, 07 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 400 200 06, 07 03, 04 300 50 200 100 100 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations AS3002F-A AS4002F-A 1500
Model Elbow type Straight type In-line type 12-REA25 10-AS2001F-06-X214 10-AS2201F-01-06-X214 10-AS2301F-01-06-X214 12-REA32 10-AS2001F-06-X214 10-AS2301F-02-06-X214 10-AS2201F-02-06-X214 6. Do not use the cylinder with its body fixed. Be sure to secure both head covers (or end covers in case of CY1R) before using the cylinder.
Electrical entry q Description 01 02 03 01 02 03 01 02 03 Mounting bolt and gasket are not included. Platinum silver Body C: Conduit VS4010-CSSub-plate Platinum silver Aluminum die-casted w T: Conduit terminal VS4010-TSSpool/Sleeve Stainless steel e U: Grommet, D: DIN terminal VS4010-SReplacement Parts Part no. No.
Minimum Stroke for Auto Switch Mounting (mm) 12 16 20 25 32 40 50 63 80 100 Auto switch model No. of auto switches mounted 1 pc. 10 5 D-A9 2 pcs. 15 10 D-A9V D-M9V 1 pc. 5 2 pcs. 10 1 pc. 15 10 5 D-M9 2 pcs. 15 10 1 pc. 15 10 D-M9W 2 pcs. 15 10 1 pc. 10 D-M9WV 2 pcs. 10 D-Z7 D-Z80 1 pc. 10 5 2 pcs. 15 10 D-Y59 D-Y7P 1 pc. 5 10 2 pcs. 15 10 D-Y69 D-Y7PV 1 pc. 5 2 pcs. 5 D-Y7W D-Y7WV 1 pc.
Note 6) The flow rate unit is based on 0C and 101.3kPa. 2 For Air Digital Flow Switch Series PFA How to Order PFA5 Remote Type Sensor Unit 10 01 Wiring specification Flow rate range 3m lead wire with connector Without lead wire Nil N 1 to 10l/min 5 to 50l/min 10 to 100l/min 20 to 200l/min 50 to 500l/min Nil N F 10 50 11 21 51 Port size Thread type Size Applicable model Flow rate (l/min)
DC1224 V DC1224 V 8 DC(+) DC(-) DC1224 V DC1224 V DC(+) 9 DC(-) / / 10 ( ) 11 / 5m / 12 2030 20 -28No.PS-OMG0001CN-H No.
Node address setting, Communication speed setting 1) Turn on (SW mode) the switch No. 10 of the 10-digit switch mounted on the SI unit. 2) Change the instance attribute value via the network as indicated below.
(Element life check) Max. contact capacity: 10 VA AC, 10 W DC Rated contact voltage (max. operating current): 125 V AC (0.08 A), 30 V DC (0.33 A) Max. contact capacity: 10 W DC Rated contact voltage (max. operating current): 30 V DC (0.33 A) Pressure drop 0.1 MPa Symbol V: Degreasing wash, white vaseline Reed switch Reed switch Body/housing is degreasing washed.
Body Assembly B Manifold mounting parts IZN10 ES 2 10 A002 01 06 Number of manifold Mounting pitch ES 17mm 2 2 stations 3 3 stations 4 4 stations Nozzle shape NIL 01 02 11 Piping female Note 1) Rc1/8 Large flow nozzle Type Energy saving charge elimination nozzle Electrode needle cleaning kit/IZS30-M2 Piping diameter 06 f6: metric 07 f6.351/4"): inch 16 f6: metric (elbow) 17 f6.351/4"): inch
Type AS1200-M3 Direct cylinder elbow type 2 Bore size JIS Symbol Direct cylinder flat elbow type 4 Symbol Bore size Applicable series Control type AS1200-M3 AS1400-M3 M3 M3 x 0.5 Meter-out Meter-in 0 1 AS120-M5 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 M5 x 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 P.15-11-3 Thread type Cylinder side R Tube side Rc Symbol Metric thread (M3
Fitting plug KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 Dimensions L (mm) A Applicable fitting size d A L D Part number KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 5 6 8.5 10 11.5 31.5 32 35 39 43 1/8 5/32 1/4 5/16 3/8 16 16 18 20.5 22 D Used to block unused cylinder port. L DIN rail AXT100-DR12.5 (Pitch) 5.25 7.5 Suffix number into from the dimension table below.