x 0.5 M5 x 0.8 Port size Top ported M3 x 0.5 M5 x 0.8 Deflection accuracy 0.03 mm or less *1) Single vane 90can be adjusted to 9010(both ends of rotation 5each) Single vane 180can be adjusted to 18010(both ends of rotation 5each) *2) Operate within the speed adjustable range.
Model Bolt Max.tightening Torgue (Nm) JMHZ2-16D M3 x 0.5 0.59 Attachment 16 - How to Mount Air Gripper (1)Mounting to the robot arm (2)Mounting of the cover Take care not to get the switch cable caught when mounting the cover.
Model Bolt Max.tightening Torgue (Nm) JMHZ2-16D M3 x 0.5 0.59 Attachment 15 How to Mount Air Gripper Adjust the robot arm position before mounting so that the mounting is easy. (1) Mounting to the robot arm (2) Mounting of the cover Take care not to get the switch cable Caught when mounting the cover.
Model Bolt Max.tightening Torgue (Nm) JMHZ2-16D M3 x 0.5 0.59 Attachment 14 How to Mount Air Gripper Connector storage Set the three connectors at the end of the robot hand according to the characters printed on the flange. The connection part of the connectors are set in the direction of the arrows.
JMHZ2-16D-X7400B-HC10-(*) P13P14P15 4 M6 31.5 2XM4x0.7 8 4 M6 108.8L 4 4 M4 4 M3 27 17 10 - JMHZ2-16D-X7400B-HC10DT-(*) 4 M6 32.5 8 4 M6 109.8L 4 4 M4 4 M3 27 17 11 - 3-6. M8 8 M8-Molex P .19 NPN PNP No. 1 +24V DC24V 2 GND DC0V 3 ON/OFF() 4 ON/OFF() 5 () 6 () 7 8 Molex (51227-0800) M8 8 12 - 3-7.
Refer to the table below Bolt pull Model Belt Pull tension Model Bolt size Tightening [N] Part number torque [Nm] EQFS25 LE-D-15-1 19.6 EQFS25 M3 0.6310% EQFS32 LE-D-19-1 49.0 EQFS32 M4 1.510% EQFS40 EQFS40 LE-D-19-2 70.0 19 - "Pulley plate" is installed.
(Only "With motor cover") (Nm) M2.5 0.3610% M3 0.6310% M4 1.510% M5 310% The fingernail of "Grommet" is inserted in the hole of "Pulley box". Grommet 43 - 7. Troubleshooting Alarms below are abstract of representative examples. For other alarms, see operation manual of controller. No.
MOT3 (6 ) 17 ENC4 (16 ) 4 18 MOT4 (6 ) ) (+)3 (+) 3 (+)4 (+)4 (+) 19 CI 3 4 ) 3 4 (+)(-) 20 M PWR 3 4 )5. 26 No.SFOD-OMT0009CN-B 4.3 (1) 5.5 (2) DIN 27 No.SFOD-OMT0009CN-B 4.4 (1) DIN (a) (4 M5 ) (M5)X4 (b) DIN DIN DIN (M5X8) DIN 2 4 3.0[Nm] M5X8 DIN 1 2 2 3.0[Nm] DIN M5X14 A DIN B DIN DIN (M5X14) 0.40.6 [Nm] 0.40.6[Nm] 28 No.SFOD-OMT0009CN-B A B M5X14 (2) M3
-38No.JXC-OMT0001CN-C (3) : CI C24V (+) (+) EMG1/EMG3 (+) 1 3 (+) (24V ) EMG2/EMG4 (+) 2 4 (+) (24V ) C24V EMG1/EMG3 EMG2/EMG4 LKRLS1/LKRLS3 LKRLS2/LKRLS4 LKRLS1/LKRLS3 + 1 3 (+) LKRLS2/LKRLS4 + 2 4 (+) PHOENIX CONTACT ( FK-MC0,5/5-ST-2,5) 2) AWG20(0.5mm oC 60 2.0 8mm -39No.JXC-OMT0001CN-C 6.2 (1)(3) C PWRCI M PWR (1) +24V 24-0V 24V 0V (24-0V) (24V) (0V) (+24V) M24V 0V 24V 0V M3
Loosen the hexagon socket head cap screws (M3 x 30:2 locations) which are fixing the SI unit. 2. Separate the SI unit to valve manifold. 3. Add and increase the attached tie-rod (2 pcs. per block) to the increased block respectively and pass through a block by the tie-rod. 4.
Caution (1)For M3, M5, 10-32UNF Tightening method (10)Do not apply excessive force or shock to For M3 First, tighten it by hand, then give it an additional 1/6 turn to 1/4 turn with a hexagon wrench. Refer to Table below for reference. the body or fittings with an impact tool.
The terminal screw is an M3 cross head screw. Note: Connect the ground terminal to ground. Resistance to ground should be 100 ohms or less. A. Single power supply used B.
Insulation resistance 1000 M Withstand voltage 1000 V Operating temperature range -30 to +55 oC VCTF 2 core cable (0.75 mm2 x 2) VCTF 4 core cable (0.75 mm2 x 4) Use the M3 crimped terminal for the connection.
The terminal screw is an M3 round head combination screw. Terminal Connection BS+ Connect the communication power supply BS+. BDH Connect the communication cable BDH. BDL Connect the communication cable BDL. BSConnect the communication power supply BS-.
B RATE Terminal board Terminal Connected to MS+ BS+ of communication power line BDH BDH of communication line BDL BDL of communication line BSBSof communication power line FG Ground line 24V 24V of solenoid valve power line 0V 0V of solenoid valve power line M3 terminal screw in use. EX##-OMF0012 8 EX##-OMF0012-A No.EX-OMF0012-B -9- 5-3. Address setting (1) ADDRESS NO.
Tighten the wiring screws (M3 slotted head screws) firmly with a tightening torque of 0.5 to 0.6 Nm. Make sure to connect "terminal resistor" between "CAN_H"-"CAN_L" to the units at the both ends of the system. Terminating resistor is 121 1%, 1/4 W (Refer to Fig. 2). Refer to Fig. 3 about how to connect to the unit.
Tighten the wiring screws (M3 slotted head screws) firmly with a tightening torque of 0.5 to 0.6 Nm. Be sure to connect a "Terminating resistor" to both ends of transmission line. (Refer to Fig. 2). Tighten the connector fixing screws (M2.5 slotted head screws) firmly with a tightening torque of 0.2 to 0.3 Nm.
Step 7 Reassembly of bonnet assembly (No.2) 3 Bolt 1 2 4 Bonnet assembly Port 1(P) Bolt size, Tool, Tightening torque of bolt (Nm) valve Bolt size Hex Tightening torque size wrench XLAV-16 M3 3 0.7 -25 M5 4 1.5 -40 M6 5 2.5 -50 M8 6 6.1 Body -63 M10 8 15 -80 Turn ON the solenoid valve to supply air pressure of 0.4MPa (G) to the port 1(P).
Air flow adjustment switch Scale Air flow [m3/min] 1 0.19 2 0.46 3 0.66 4 0.80 4-4. Maintenance Warning Function and Cleaning If the product is used for an extended period with dust present on the emitters, the product performance will be reduced.
Tightening torque (1) Round head combination screw (M2.5 x 41): 0.3 to 0.36 Nm (4) Hexagon socket head cap screw (M3 x 30): 0.6 to 0.66 Nm Replacement procedure of ZL212-SP01 (Silencer set) Disassembly and Reassembly 1. Remove the four round head combination screws (M2.5 x 53) (1). 2.