to 8 2.5 to 11 4 to 18 4 to 18 6.5 to31.5 6.5 to 31.5 Internal 1.3 x 10-10 for the standard material (FKM) Leakage at ambient temperatures , excluding gas permeation Pam3/s External 1.3 x 10-11 for the standard material (FKM) at ambient temperatures , excluding gas permeation Flange type KF (NW) KF (NW) , K (DN) Main material Body: aluminum alloy, Bellows: SUS316L, Main part: SUS304 and FKM
No 1 2)3) 4) 5)6) 6) 5)6) 7) O 8) 9) 10) 11) 12) 13) 1 2)3) 4) 14) 15) 10) 11)16) 28 No.ZL3-OM00801-A No 1 ON 10 2) 3) 4) 5) 6) 7) 8) O O 9) 10) 11) 12) 13) 14) 15) ON/OFF 16) 29 No.ZL3-OM00801-A Revision history AUKCA marking added 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com
M N C D 4-O T Q 2-P E B S K L U W AA A I AP R X AB Y + Stroke J V Z + Stroke AC AD 8-AF AE For standard stroke (mm) Bore size (mm) Stroke range (mm) AC E D AF G AE AD AB AA N M F L K B J AP C H I A 20 25 32 40 50 75, 100, 125, 150, 200 M5 x 0.8 depth 10 16.5 92 60 9.5 depth 6 30 75 11 12 45 25 5.5 80 60 55 108 M8 x 1.25 depth 14 25 24 30 99 M6 x 1 depth 12 16.5 113 65 11 depth 8 30 85 13
B C d H MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M NTJ-015A NT-015A NT-02 NT-03 NT-04 10 8 9.2 6 15.5 5 10 9.2 M5 x 0.8 4 20.5 8 16 8 9.2 8 16.5 6 16 11.5 M6 x 1.0 5 22.5 10 20 8 9.2 10 18.5 6 20 15 M8 x 1.25 5 24.5 13 25 10 11.5 12 22.5 11 25 19.6 M10 x 1.25 6 33.5 17 28 14 16 16 28.5 12 28 25.4 M14 x 1.5 8 40.5 22 Applicable bore (mm) Part no.
10 5 20 10 to 60 47.5 M6 x 1.0 37.5 10 10 40 5.5 M5 x 0.8 7 52 8 10 28 5.4 9 19.5 10 6 25 10 to 50, 75, 100 54 M6 x 1.0 42 12 12 45 8.5 M6 x 1.0 7 60 4.5 10 12 34 5.5 9 23 10 49.5 7 28 10 to 50, 75, 100 60.5 M6 x 1.0 48.5 13 16 52 8.5 M8 x 1.25 7 69 5 14 12 40 5.5 9 26 10 57 10 With rod end male thread: MQQDM Rod end nut H1 Bore size (mm) L1 C1 H1 X 10 23.5 10.5 M5 x 0.8 15.5 16 26.5
0 13 12 11 10 9 8 7 6 5 4 3 2 1 0 50 100 150 200 250 3000 mm/s2 3000 mm/s2 Work load: W [kg] Work load: W [kg] 5000 mm/s2 10 mm/s2 0 0 Speed: V [mm/s] 50 100 150 200 250 Speed: V [mm/s] 10 Easy to Operate EQFSH Series Battery-less Absolute (Step Motor 24 VDC) SpeedWork Load Graph (Guide) EQFS25HH/Ball Screw Drive Horizontal/Lead 20 Vertical/Lead 20 2.5 16 14 12 10 8 6 4 2 00 200 400 600 800
15 5 10 5 10 10 5 10 D-A9 D-A9V D-M9V D-M9 10 10 10 10 D-M9W D-M9WV D-M9AVL 15 10 D-M9AL 15 10 5 D-Z7 D-Z80 D-Y59 D-Y7P D-Y69 D-Y7PV D-Y7W D-Y7WV 15 10 10 15 10 5 5 5 10 15 15 10 15 D-Y7BAL 10 20 75 18-3.
Air or fluid leakage Check if air or fluid are leaking from the piping. 11 After energizing, the display and output can drift. For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time. Insufficient warm-up time Product failure Replace the product.
Fittings & Tubing Air Cylinders Rotary Actuators 10 9+ST 4 x M3 x 0.5 thread depth 3.5 8 2.7 6.7 2 x M3 x 0.5 thread depth 3 (Piping port) Steel ball 4.5 15 M3 x 0.5 thread depth 3.5 Vacuum suction port 24.5 25 Note) 11-, 22-: Vacuum suction port 12-, 21-: Relief port ST 13.4 47+ST 11 1.2 37+ST 5.5 4.5 10+ST 3.8 3.8 11 2.75 M3 x 0.5 x 3 L M8 x 1.25 x 8 L (Bolt holder) (Hexagon socket set
Configuration Minimum equipment and wiring requirements to get started 1 Provided by customer Ex) 1-Phase 200 VAC (*1) 7 Provided 6 1 by customer 8 2 3 N PC 3 4 5 9 C D 11 21 10 4 (*2) U 2 Electric Actuators Ex) LEF V W Provided by customer 3 PLC (CC-Link master unit) 11 (*1) Refer to LECSC2-T Operation Manual, Chapter 4 for further details if the power supply voltage is 3-Phase 200VAC.
Settable range : 10...988 (1.0 kPa...98.8 kPa) Combination conditions with other parameters : 10 H1 P1-1 (50) ... ... ... ... ... 16 2 R/W 0x0032 Vacuum confirmation hysteresis (H1) of CH15 (50) 3.4.3. Pressure P2 (Index 66) Table 3-11.
6 x M5 x 0.8 thread depth 10 (A, B, C common view) 50 +0.02 0 (A, B, C common view) 3 x 5 depth 10 16h9 0 0.043 2 10 38.5 22 (76) 70 11 25 2 12 0 0.05 5 0 0.03 5 0 0.03 4 Open: 37 Closed: 19 2 x M5 x 0.8 thread depth 10 (Thread for mounting attachment) 25 25 7 7 10 10 502 Series MHR2/MDHR2 Rotary Actuated Air Gripper 2-Finger Type With auto switch (Built-in magnet) : MDHR2-30R 76 73
Metric size Inch size Type Elbow Universal 2 3 1 8" 5 32" 23 01 3.2 4 6 8 10 12 04 06 08 10 12 03 05 07 09 11 13 3 16" 1 4" 5 16" Control type Meter-out Meter-in 0 1 3 8" 1 2" Use 1/8" tube.
21.6 70.4 Fitting size VAC/SET Straight R Elbow S Elbow T Elbow U 8 8.5 11 14 Elbow V 26.5 6 1/4" 8, 5/16" 10, 3/8" 10.5 10.5 10.5 11 21 21 21 21 27.5 27.5 28.5 30.5 1 1.5 4 7 65 26.6 40.5 5.2 7 Options One-touch Fittings for Vacuum Regulator Bracket Assembly Bracket For IRV10(A) P601010-17 For IRV20(A) P601020-17 One-touch fitting for IRV10(A) 51A C6 VVQ1000 Bracket Fitting type Fitting
(For the part number of the dew point indicator, refer to pages 10 and 11.) 3.
C common view) 2 10 38.5 22 (76) 70 11 25 2 12 0 0.05 5 0 0.03 5 0 0.03 4 Open: 37 Closed: 19 2-M5 x 0.8 thread depth 10 (Thread for mounting attachment) 25 25 7 7 10 10 12-5-16 17 2 Finger Rotary Actuated Air Gripper Series MHR2/MDHR2 With auto switch (Built-in magnet): MDHR2-30R 76 73 B 3-M5 x 0.8 thread depth 10 MDHR2-30E Port Location P .C.D.43 (Mounting thread) MHZ 80 MHF 120 MHL MHR
Torr (mmHg) 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 10 102 3. Mount a valve with its coil position upward, not downward. 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 101 102 103 104 105 106 107 108 109 Pa Vacuum piping direction: if the system uses a vacuum pump, we ask that you install the vacuum pump on the secondary side.
ZFB300-10 10 (N)ZFB101-05 53 24 17.5 316" 48 26 22.5 12.5 15 50 15.5 14.4 12.8 8.5 (N)ZFB101-07 54 24.2 17.7 14" APPLICATION T O E J E C T O R S Y S T E M Inch size (N)ZFB201-07 52 28 65 24.5 13.5 27.2 19.7 16 61 17.5 16.6 15.2 14" 9.5 (N)ZFB301-11 57 30 70 27 14.5 30.2 21.7 17 65 21.5 8 18.5 38" 11 (N)ZFB401-13 64.5 34 87.5 30.5 16.5 34 24 21.5 81 25.6 23 21.7 12" 13.5 H O W T O O R D E
Hyrodless Monosashi-kun (with Stroke Adjustment Unit, X417) 31 Chapter 9: Construction / Parts List 32 Chapter 10: Cushion Capacity 10-1. Cushion Selection 33 10-2. Absorbing Capacity of Air Cushion, Stroke Adjustment Unit 34 10-3. Adjusting Method 35 Chapter 11: Stopping Operation 11-1. Over run 36 11-2.