) + b (2) Conversion formula from the flow gauge measurement value to the process data: (PD) = (Pr b) / a Pr: Flow measurement value and pressure set value PD: Flow measurement value (process data) a: Inclination b: Intercept [Inclination and intercept to the unit specification] Series Unit Flow range Inclination a Intercept b 1 L 0.00025 0 2 L 0.0005 0 5 L 0.00125 0 L/min 10 L 0.0025 0
JXC-OMT0028CN (GW)(EtherNet/IP) / LEC-GEN1 . 4 2. . 6 2.1 . 6 2.2 . 6 2.3 . 7 2.4 () . 8 (1) . 8 (2)GW . 8 (3)LEC . 8 (4)GW . 8 (5)GW . 8 (6) . 9 (7) . 9 3 . 10 3.1 . 10 3.2 . 12 3.3 . 13 (1)(LECGEN1) . 13 (2)DIN (LECGEN1D) . 13 3.4 . 14 (1) . 14 (2) . 14 4. . 15 4.1GW (B RATE) . 15 4.2 (CN2SW) . 16 4.3LEC . 16 4.4GW EtherNet/IP . 22 5. . 26 5.1 CN4 . 26 5.2 CN3 . 26 5.3
If the installation is using accurate control, wait until the product has warmed up (approximately 10 to 15 minutes).
] 15 [0.10] 15 [0.10] 7.3 [0.05] 7.3 [0.05] 7.3 [0.05] 0.00 0 1.3 [5] 2.6 [10] 4.0 [15] 5.3 [20] 7.9 [30] 9.2 [35] 11 [40] 12 [45] 6.6 [25] 0.00 0 1.3 [5] 2.6 [10] 4.0 [15] 5.3 [20] 7.9 [30] 9.2 [35] 11 [40] 12 [45] 13 [50] 15 [55] 16 [60] 6.6 [25] 0.00 0 0.1 [0.5] 0.3 [1] 0.4 [1.5] 0.5 [2] 0.8 [3] 0.9 [3.5] 1.1 [4] 1.2 [4.5] 1.3 [5] 0.7 [2.5] Flow rate gal/min [L/min] Flow rate gal/min [
(inch) M Weight (g) A D L1 L1 Applicable tubing M 10 16 18.3 18 3.5 KQGL03-32 10-32UNF 10.6 20.5 18 5/32 12 19.5 20.7 21 4.2 KQGL03-N01S D NPT1/8 A 10 17 20.5 25 3.5 KQGL07-32 10-32UNF L2 12 13 20.5 22.1 22.9 27 18.8 KQGL07-N01S 1/4 NPT1/8 H Connection thread 9 14 24.5 25.2 35 KQGL07-N02S NPT1/4 12 21.9 25.3 37 KQGL09-N01S NPT1/8 (In case of R) 15 14 25.9 24.9 27.6 45 20.9 21.6 KQGL09-N02S
Status Condition 0 No supply voltage SP Status of solenoid power supply 1 Supply voltage OK 0 Short circuit DI Status of sensor power supply 1 Normal Output area mapping Output data MSB LSB MSB LSB Offset (word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 -28No.EX-OMK0004-B Output No. assignment Combinations of output data and valve
L 60.5 3 48 2 85.5 5 73 4 110.5 7 98 6 135.5 9 123 8 160.5 11 148 10 185.5 13 173 12 210.5 15 198 14 235.5 17 223 16 19 248 18 20 VS 260.5 285.5 21 273 No.
size (mm) 4 5 7 10 Symbol 4 5 7 10 Class 3 Class 4 Voltage 1 2 3 4 5 6 100VAC 200VAC 110VAC 220VAC 24VDC 12VDC Manual override None Slotted locking type (tool required) Nil B Consult SMC regarding other voltages.
24 18 40 5.5 M6 x 1.0 9 Rc1/8 26 14 10 5.5 7 4.5 57 14 50 118.5 96.5 16 35 64 37 14 12 M10 x 1.5 86 7 30 22 50 6.6 M8 x 1.25 11 Rc1/4 30 17 14 3 8 5.5 71 19 63 130 102 39.5 36.5 21.5 21 45 77 16.5 15 M16 x 2.0 103 7 36 28 60 9 M10 x 1.5 14 Rc1/4 18 4.5 10.5 6.5 84 19 10-10-10 11 3 Position Cylinder Series RZQ Foot style: RZQL Foot Style (mm) B + Full stroke L Bore size (mm) A LH LS B L LD
) 0.6 0.7 Critical pressure 0.65 [658] (158) 0.5 0.6 0.55 Sonic [656] (151) 0.5 0.4 0.45 [654] (143) 0.4 0.3 0.35 0.3 [650] (133) 0.2 0.25 0.2 [646] (120) 0.15 0.1 0.1 0.05 2 2 2 2 3 2 3 2 3 2 03 04 VX211 VX22 VX23 VX2 4 VX2 50 VX2 60-02 VX2 602 10 15 5 3 5 10 15 20 25 30 4.5 10 15 20 30 40 50 60 3 2 6 30 60 8 25 35 10 20 40 10 35 Flow rate Q kg/h Figures inside [ ] indicate the saturated
(mm) 4 6 8 10 12 I.D. (mm) 2.5 4 6 7.5 9 White (W) Black (B) Red (R) Blue (BU) Yellow (Y) Green (G) Air/Nitrogen gas/Water (Pure water) (1) Fluid Max. operating pressure (at 20C) 1.0 MPa (2) 0.7 MPa (2) Min. bending radius (mm) 25 35 45 55 15 Refer to the burst pressure characteristics curve.
L 60.5 3 48 2 85.5 5 73 4 110.5 7 98 6 135.5 9 123 8 160.5 11 148 10 185.5 13 173 12 210.5 15 198 14 235.5 17 223 16 19 248 18 20 VS 260.5 40 285.5 21 273 No.
L/min) PF2A710 A 1 10 PF2A750 B 5 50 PF2A711 C 10 100 PF2A721 D 20 200 PF2A751 E 50 500 -37No.PF-OMO0007CN PF2A710/750 PF2A711/721/751 -38No.PF-OMO0007CN ()ZS-37-A (L )ZS-37-B ZS-29-T -39No.PF-OMO0007CN NPN(1 ) + (15 V) NPN(1 ) + (420 mA) PNP(1 ) + (15 V) PNP(1 ) + (420 mA) 10 PF2A7 NPN(1) + (15 V) PF2A7--28--X560 PNP(1) + (15 V) PF2A7--68--X560 NPN(1) + (420 mA) PF2A7--29--X560 PNP
(UP) (SET) (DOWN) LCD (OUT1)/ OUT1OUT2 ON ON/OFF (UP) (SET) ON/OFF (DOWN) -11No.PF-OMP0001CN-F F.S. () 15 V F.S.=5[V]1[V]4[V] 1F.S.4[V]10.04[V] 15 V 15 V 420 mA ON OFF () (0100)( ) 90 () (0100) ()90ON(OFF) () 10 L/min 10 L ON OFF ON ()OFF () 0 -12No.PF-OMP0001CN-F , ,2 5 10 L/min 5 ,51050 L ON-OFF () 1 L/min ,101112 1 L/min SI SI ON-OFF ON 0 ripple -13No.PF-OMP0001CN-F
Pressure range Switch 100 kPa 0 0.5 MPa 10 MPa 15 MPa 0.4 MPa 1 MPa 0 1 MPa For 1 MPa (For Air) ISE70 100 kPa (0.1 MPa) 1 MPa For 10 MPa (For General Fluids) 10 MPa 0 ISE75 10 MPa 0.4 MPa For 15 MPa (For General Fluids) 0 15 MPa ISE75H 0.5 MPa 15 MPa The ISE75(H) switch shows zero (0) when the pressure being applied goes below the lower limit of the set pressure range, when the cut-too-zero
15 FG Fixed screw: M2.6 HEC002-A/HEC006-A 10-1 Appendix 10.2 Calculation of dew point (from psychometric chart) Relative humidity (%) 55 100 90 80 70 60 50 45 40 B A 35 30 4 10 13 20 24 30 Temperature (deg.C) Fig.10-1 Moisture air diagram 1) Measure the ambient temperature and relative humidity. 2) Plot the ambient temperature on the horizontal axis (Ex. 24 C), and then draw a perpendicular
measurement value (PD) Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 OUT2 OUT1 Item Error output Reservation Flow Fixed Diagnosis Reservation Diagnosis Switch output The process data of this product is Big-Endian type.
(Full span) Indication precision G46-10-02-SR A, B Fluid contact part cleaning (Wetted part) Precision cleaning General degreasing Be sure to read the precautions on page 14-11-15 for selection and installation.
less 31 49 37 5 or less 20 190 35 62 50 10 or less 39 66 33 5 or less 30 190 39 68 43 10 or less 43 72 29 5 or less 50 190 49 83 33 10 or less 53 87 22 5 or less 70 190 54 95 30 10 or less 58 99 21 5 or less 100 190 61 108 27 10 or less 65 112 18 5 or less 200 190 81 139 21 10 or less 85 143 15 5 or less Operating range m: Value of the operating range Lm of a single auto switch converted