Base Mounted Wiring: 01 (Plug-in, Insert Plug w/Lead Wire), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 7 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 01 (1/8), Thread: T (NPTF), Control Unit: AP (Air Filter w/Auto Drain, Regulator, Air Release Valve,Pressure Switch), Voltage of Air Release
Base Mounted Wiring: 01 (Plug-in, Insert Plug w/Lead Wire), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 2 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 01 (1/8), Thread: T (NPTF), Control Unit: None, Voltage of Air Release Valve: w/o Air Release Valve, Q: Q (CE Marked)
Base Mounted Wiring: 01 (Plug-in, Insert Plug w/Lead Wire), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 3 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 01 (1/8), Thread: T (NPTF), Control Unit: None, Voltage of Air Release Valve: w/o Air Release Valve, Q: Q (CE Marked)
Base Mounted Wiring: 01 (Plug-in, Insert Plug w/Lead Wire), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 3 Stations, Passage: 2 (P and EA,EB: Common, Port A,B: Bottom), Port Size: 01 (1/8), Thread: T (NPTF), Control Unit: None, Voltage of Air Release Valve: w/o Air Release Valve, Q: Q (CE Marked)
Base Mounted Wiring: 01 (Plug-in, Insert Plug w/Lead Wire), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 6 Stations, Passage: 2 (P and EA,EB: Common, Port A,B: Bottom), Port Size: 01 (1/8), Thread: T (NPTF), Control Unit: None, Voltage of Air Release Valve: w/o Air Release Valve, Q: Q (CE Marked)
Base Mounted Wiring: 01 (Plug-in, Insert Plug w/Lead Wire), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 4 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 01 (1/8), Thread: T (NPTF), Control Unit: A (Air Filter w/Auto Drain, Regulator, Air Release Valve), Voltage of Air Release Valve: 5 (24VDC
.: AMX-OMX0018-B PRODUCT NAME Line filter MODEL / Series / Product Number AFF20-(F, N)01 ~ (F, N)02(B, C)(-2, 6, C, J, L, R, Z)-D AFF30-(F, N)02 ~ (F, N)03(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D AFF40-(F, N)02 ~ (F, N)04(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D Contents Page 1. Safety Instructions 2 to 7 2. Application 8 3. Standard specifications 8 4. How to order 9 5.
.: AMX-OMX0019-C PRODUCT NAME Mist Separator MODEL / Series / Product Number AM20-(F, N)01 ~ (F, N)02(B, C)(-2, 6, C, J, L, R, Z)-D AM30-(F, N)02 ~ (F, N)03(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D AM40-(F, N)02 ~ (F, N)04(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D Contents Page 1. Safety Instructions 2 to 7 2. Application 8 3. Standard specifications 8 4. How to order 9 5.
.: AMX-OMX0020-B PRODUCT NAME Micro Mist Separator MODEL / Series / Product Number AM20-(F, N)01 ~ (F, N)02(B, C)(-2, 6, C, J, L, R, Z)-D AM30-(F, N)02 ~ (F, N)03(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D AM40-(F, N)02 ~ (F, N)04(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D Contents Page 1. Safety Instructions 2 to 7 2. Application 8 3. Standard specifications 8 4. How to order 9 5.
P A B C D E G J M N Q R S T U V AMK20 1/81/4 40 133.9 17.5 21 25 21 30 27 22 5.4 8.4 60 2.3 28 AMK30 1/43/8 53 167 21.5 26.5 30 35 26.5 41 35 25 6.5 13 71 2.3 32 AMK40 1/43/81/2 70 212.5 25.5 35.5 38.4 40 35.5 50 52 30 8.5 12.5 88 2.3 39 semi-standard bowl Semi-standard specifications Model Metal bowl No.
AF-OMX0054-B PRODUCT NAME Micro Mist Separator MODEL / Series / Product Number AFD20-(F,N)01(F,N)02(B,C)(-2,6,C,J,L,R,Z)-D AFD30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFD40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFD40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-D Contents Page 1. Safety Instructions 2-7 2. Application 8 3. Standard Specifications 8 4. How to Order 9 5.
cylinder adjustment (cushion needle adjustment). 200 150 Cushioning quality (RHCF40-500, load weight 5kg, supply pressure 0.5MPa, horizontal drive) High power cylinder 500 General purpose cylinder Cushioning capacity [J] 100 1000mm/s 3000mm/s 2000mm/s 500mm/s 400 Stroke [mm] 300 50 200 100 50mm/s 20 25 32 40 50 63 80 100 0 1.0 0 2.0 10 Time [s] Cylinder size [mm] Features 1 : Series RHC t
Vacuum Pad: Ball Joint Type Series ZPT/ZPR Pad diameters: 10, 13, 16, 20 25, 32, 40, 50 rp ti on so ad on r sl fo a nt al e e d id w e or p ty k t s in u rf o j a ll c a e B s Series ZPT: Vertical vacuum entry type Series ZPR: Lateral vacuum entry type One-Touch fitting Vacuum Pad: Ball Joint Type Series ZPT/ZPR Pad diameters: 10, 13, 16, 20, 25, 32, 40, 50 Pad materials: NBR, Silicon rubber
IZ*-OMP0064 E P r o d u c t Ionizer Model/Series IZS4 Series Contents Safety Instructions . 1. How to Order . 1-1. Ionizer . 1-2. Accessories . 1-3. Option . 2. Installation . 2-1. Installation of ionizer . 2-1-1. Selection of piping port size . 2-1-2. Distance for installation . 2-1-3. Mounting and installation of the bracket . 2-2. Installation of the external sensor. 2-3.
Note 3) Refer to the operation manual for handling of the remote controller. 0 to 45C 35 to 80% RH (with no condensation) 33 g (excluding dry cell batteries) CE Ambient temperature Ambient humidity Weight Standards/Directive Construction IZS40 series y r t q e Description No.
Similarly, for valves which had an “N” prefix, the thread type now needs to be indicated in the part number (e.g., symbol “N” for NPT thread or “T” for NPTF thread)
Valve part number example: Plug-in type NVT307-5DO-01→VT307-5DO-01T
Be aware that NVFR/NVFS series valves were of the body ground type.
If body grounding is required, suffix a “-Q” to the part number.
Appendix F: Safety Characteristics Operation Output with Two Output with Outputs Two Channel Single Channel Channel Single Channel (only) Input (only) Input (only) Item Input Input SFF 99.98% 99.98% PFDAV (T) 1% of 10-3 1% of 10-2 Average Probability of Dangerous Failure PFH (T) 1% of 10-7 1% of10-6 Probability of dangerous failure per hour Achievable Safety Level SIL3 / PL e SIL2 / PL d
/PL / 16 108 No.EX##-OMY0006CN 22.F + + SFF 99.98% 99.98% PFDAV (T) Average Probability of -3 1% of 10 -2 1% of 10 Dangerous Failure PFH (T) Probability of dangerous -7 1% of10 -6 1% of 10 failure per hour Achievable Safety Level SIL3 / PL e SIL2 / PL d SIL3/PL e SIL2 PL d 109 No.EX##-OMY0006CN 23.GEX245-FPS EX245-FPS1/2/3 Input delay : tFilter + 2 ms tFilter = Parameterized filter
Cables, connectors and hub shall comply with the IEEE802.3 10BASE-T/100BASE-TX standard.
Table 1 Moment of inertia Size Allowable kinetic energy (J) 10 0.00015 15 0.00025 20 0.0004 30 0.015 40 0.03 How to calculate the load energy E : Kinetic energy (J) I : Moment of inertia (kg m Speed (rad/s) : Rotation angle (rad) 1803.14 rad t : Rotation time (s) 1 E = I 2 2 2 = t Table 2 Safety operable rotation time adjustment range Size Rotation time ( s / 90) 10 0.03 to 0.5 15