to 150 10 to 150 10 5 5.5 to 11.2 5.4 to 9.0 4.4 4.4 3.3 3.3 10 to 200 10 to 200 10 to 150 10 to 150 10 10 2.8 to 5.6 2.7 to 4.5 3.3 3.3 2.2 2.2 20 to 350 Note 4) Basic Compact Basic Compact Basic Compact Basic Compact Basic Compact Horizontal Max. work load [lb] Note 2) Note 3) Vertical Actuator specifications Electric specifications 20 to 300 Note 4) Horizontal 20 to 350 Note 4) Speed
50 60 70 80 10 20 Work load [kg] Work load [kg] LEJS63/Ball Screw Drive: Vertical LEJS63;A LEJS63;B 20 Duty ratio: 50% 20 Acceleration/Deceleration [mm/s2] Acceleration/Deceleration [mm/s2] Duty ratio: 50% 15000 15000 10 10 Duty ratio: 75% Duty ratio: 75% 5000 5000 0 0 0 10 2.5 5 7.5 0 20 15 5 10 Work load [kg] Work load [kg] LEJB40/Belt Drive: Horizontal LEJB63/Belt Drive: Horizontal 20
L FT B + Stroke G Stroke range 20FD FT FV FX FZ G L L1 M B A A B 91 36 10 to 50 63 46 101 9 9 80 92 108 38 8 33.5 60 Data 101 46 75, 100 107.5 43.5 10 to 50 80 53.5 117.5 11 11 99 116 134 43 10 43.5 77 117.5 53.5 75, 100 126 53 10 to 50 Rod end nut L1 100 63 136 11 11 117 136 154 50 12 43.5 94 136 63 75, 100 Double Clevis Style Double clevis style: CLQD/CDLQD Stroke range Without auto switch
Bore size (Stroke (mm)) 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 Applicable Auto Switches/Refer to Best Pneumatics No. 3 for further information on auto switches.
11 depth 6.5 63 1/4 19.5 10 40 65 55 10 22.4 19 M16 x 2 20 7 52 9 14 depth 8.6 71 1/4 20.5 10 50 71 60 11 28 24 M20 x 2.5 24 8 58 11 17.5 depth 10.8 81 1/4 22 10 63 80 67 13 35.5 30 M27 x 3 33 9 69 13 20 depth 13 97 1/4 25.5 10 80 95 78 17 45 41 M30 x 3.5 36 14 86 15 23 depth 15.2 117 3/8 30 15 100 122 96 26 56 50 M39 x 4 45 21 106 17 26 depth 17.5 142 3/8 36 15 Note 1) Body dimensions are
10 10 10 ORIG ACC/DEC 1000 1000 1000 1000 Creep speed 10 10 10 10 ORIG sensor 0 0 0 0 ORIG SW Dir 0 0 0 0 Undefined parameter21 0 0 0 0 101 - Appendix 1.5 LER series setting value LER Step data default Model LER10K LER10J LER30K LER30J LER50K LER50J Gear Ratio [] 8 12 8 12 7.5 12 No. 0 0 0 0 0 0 Movement MOD ABS ABS ABS ABS ABS ABS Speed 280 420 280 420 280 420 Position 0.00 0.00 0.00 0.00
107.5 117.5 126 136 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75, 100 FV 63 101 46 9 9 M 80 117.5 53.5 11 11 4 x FD G B + Stroke L FT FX FZ A + Stroke 100 136 63 11 11 Bore size (mm) FV FX FZ G L L1 M 63 80 100 80 99 117 92 116 136 108 134 154 38 43 50 8 10 12 33.5 43.5 43.5 60 77 94 Rod end nut L1 Double clevis style: CLQD/CDLQD 4 x N Cap bolt CT Head Side Flange Style (mm) CD hole H10
-125 14-150 18-150 22-150 26-150 30-150 36-150 Model Symbol Applicable bore size (mm) 6 10 10, 15 20 25, 30 40 50, 63 80 100 125, 140 160 6 10 15 20 30 40 63 80 100 140 160 Maintenance Standard Warning 1.
-125 14-150 18-150 22-150 26-150 30-150 36-150 Model Symbol Applicable bore size (mm) 6 10 10, 15 20 25, 30 40 50, 63 80 100 125, 140 160 6 10 15 20 30 40 63 80 100 140 160 Maintenance Standard Warning 1.
38 8 33.5 60 46 101 75, 100 43.5 107.5 10 to 50 80 117.5 53.5 11 11 99 116 134 43 10 43.5 77 53.5 117.5 75, 100 53 126 10 to 50 Rod end nut L1 100 136 63 11 11 117 136 154 50 12 43.5 94 63 136 75, 100 Double clevis type: CLQD/CDLQD Double clevis type (mm) CT 4-N Cap bolt Stroke range Without auto switch With auto switch Bore size (mm) CD CT A A B CL B CL 10 to 50 75, 100 10 to 50 75, 100
Torr (mmHg) 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 10 102 3. Mount a valve with its coil position upward, not downward. 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 101 102 103 104 105 106 107 108 109 Pa Vacuum piping direction: if the system uses a vacuum pump, we ask that you install the vacuum pump on the secondary side.
10 15 15 20 MS4-10 MS5-10 MS6-15 MS6-15 MS8-20 Left Right Left Right Operating direction of the housing Operating direction of the housing Manufactured by Misumi Trading Ltd.
38 8 33.5 60 46 101 75, 100 43.5 107.5 10 to 50 80 117.5 53.5 11 11 99 116 134 43 10 43.5 77 53.5 117.5 75, 100 53 126 10 to 50 Rod end nut L1 100 136 63 11 11 117 136 154 50 12 43.5 94 63 136 75, 100 Double clevis type: CLQD/CDLQD Double clevis type (mm) CT 4-N Cap bolt Stroke range Without auto switch With auto switch Bore size (mm) CD CT A A B CL B CL 10 to 50 75, 100 10 to 50 75, 100
15-10 RS Q G RS H A RZQ Series CVM5/CVM5K 20 25 32 40 Standard MI W S 10-15-16 10-15-26 Double acting Nonrotating rod CEP1 CE1 Series CVM3/CVM3K Single acting (Spring return) (Spring extend) CE2 20 25 32 40 Standard 10-15-31 10-15-44 ML2B Nonrotating rod C J G5-S CV Series CV3/CV3K 40, 50 63, 80 100 Standard 10-15-50 MVGQ Double acting Nonrotating rod 40, 50 63 CC 10-15-63 RB Series CVS1/
0.015 0.024 0.008 0.016 10-V124A Note 1) Note 1) 10-V124 and 10-V124A: Supply pressure to port 3 and exhaust from port 1.
thread (2 each) Sides (2 each) Bottom mount 0.06 in3 (1.07 cm3) Leak rate Across the seat leak Surface finish Connections Actuation pressure Actuation port connection Actuation port location Installation Internal volume Adjustable range of metered flow 2) 10 to 200 slpm 10 to 350 slpm 6 slpm 10 slpm 15 slpm 20 slpm 10 to 20 slpm 21 to 50 slpm 51 to 100 slpm 101 to 200 slpm 201 to 350 slpm
(Different surfaces) 15 15 15 1 pc. 15 15 10 2 pcs. (Same surface) 25 25 25 D-A9V 2 pcs. (Different surfaces) 10 10 10 1 pc. 5 5 5 2 pcs. (Same surface) 30 30 30 D-M9V 2 pcs. (Different surfaces) 10 10 10 1 pc. 5 5 5 2 pcs. (Same surface) 55 55 55 D-M9 D-M9W 2 pcs. (Different surfaces) 15 15 15 1 pc. 15 15 10 2 pcs. (Same surface) 30 30 30 D-M9WV 2 pcs.
Vacuuming Graphs Top cover Seal separator LJ1H10 Vacuuming flow characteristics Particle concentration (Particles/ft3) Particle concentration (Particles/ft3) 10 Speed: 400mm/s Dust seal 10 Speed: 600mm/s 10 Side cover 200 150 100 50 25 Vacuuming flow (l/min ANR) LJ1H20 Vacuuming flow characteristics 10 Speed: 500mm/s 10 Speed: 1000mm/s 10 200 150 100 50 25 Vacuuming flow (l/min ANR) Particulate
Range Resolution LAT3-10 0 to 10 Refer to the 0.03 LAT3-20 0 to 20 Area Range table on the LAT3-30 0 to 30 right. LAT3M-50 0 to 50 LAT3F-10 0 to 10 LAT3F-20 0 to 20 0.005 LAT3F-30 0 to 30 LAT3F-50 0 to 50 This determines the condition for when the INF signal is activated. The INF signal turns ON when the pushing force generated by the Card Motor exceeds the 0.5 to 5.0 set value.