VHS20 to 50-A . ; . ; Built-in silencer (Option) = = @ @ 2 1 (IN) 2 (OUT) IN OUT B B : : Cross section of EXH port > > 3 (EXH) EXH Option Part No.
Communication A B RS-485 RS-232C Select B when communication is not used. Specifications (For details, please consult our Product Specifications information.)
Conduit terminal: VP3145-T A B DIN terminal: VP3145-D A B [105] 76 Light (For TL, TZ) 30 31.3 Max.12 G1/2 Applicable cable 6 to 12 Light position (For DL, DZ) G1/2 [196] NO NO 190.6 194 181.5 166 PE PE 26 26 83 83 32 32 36 36 80 80 [ ]: With indicator light (TL, TZ) 1310 Large Size 3 Port Solenoid Valve VP3165 Series Dimensions: VP3165 Grommet: VP3165-G A B 113 87.4 54 30 71 101 G1/2 1
A B A B DIN terminal: VP3165-D Conduit terminal: VP3165-T Conduit terminal with indicator light (TL) Light Light G 1/2 Max. 11 Applicable cable 6 to 12 G 1/2 Rc 1/4 ( ): With indicator light (TL) 4-10-6 7 Large Size 3 Port Solenoid Valve Rubber Seal Series VP3145/3165/3185 Dimensions: VP3185 A B Grommet: VP3185-G V100 G 1/2 SY SYJ Manual override Lead wire length 200 mm External pilot
PBT 2 B Port plug 2 Bonnet PBT, HNBR Refer to page 705.
Description Body cover Bearing cap Damper End cover A End cover B Photomicrosensor Sensor plate Connector A Connector B No.
2302) VNA (JIS B 6349) VNA 1 ISO VG32 VNA ( JIS K 6439) VNA VNA VNA VNA AS AS AS AS VNA AS 10A 111 420-03 3/8 B(9.5) 12 12 12 12(P1) (P1) (P1) (P1) 10(P2) 10(P2) 10(P2) 10(P2) 12(P1)10(P2) 15A 211 420-04 1/2 B(12.7) 20A 311 500-06 3/4 B(19.1) 25A 411 600-10 1 B(25.4) 2 32A 511 800-12 1 1/4 B(31.8) VNA01 VNA02 VNA03 VNA1 40A 611 900-14 1 1/2 B(38.1) (P1) () 12 50A 711 900-20 2 B
Double acting PA PA B A PB B A With by-pass Suck back valve Manual Operation-Series LVH N.C. Double acting P PA PA Locking and non-locking types available B A B A PB B A Integral fitting type/Threaded type Manifolds Main applications and fields For shut off For air bleeding N.C.
Insulation oil A H Polyacetal Note 1) Note 1) Non-leak (10 6 Pam 3/s) Brake oil Water (up to 60C) B P A H Stainless steel Note 1) If using for other fluids, please contact SMC.
8370: JIS B 8361: JIS B 9960-1: (1 : ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4. 4 No.EX-OMW0014CN-A / *3) 1 1.5 3) 1 1 5 No.EX-OMW0014CN-A () () () () 6 No.EX-OMW0014CN-A / () * UL , UL1310 Class2 7 No.EX-OMW0014CN-A * IP65 / *() SI SI SI () ()SI SI * IP65 EX245-SPN1A/EX245-SPN2A //M12 I/O EX245-SPN3A / 7/8 M12 M12 I/O SI ( ) () 8 No.EX-OMW0014CN-A CE * SI IO IO *
How to determine the auto switch installation position MHZ2 Step 2) Insert auto switch into the switch installation groove from direction B. "Set up as directed with power connected under no pressure or low pressure." A B MHZJ2 MHQ Step 3) Slide the auto switch in the direction of the arrow until the light illuminates.
Operating pressure (MPa) 1778 Series VPA450/470 5 Port Air Operated Valve Flow Characteristics/Mass Port size Function Flow characteristics Mass (kg) 14/2(PA/B) 4/25/3(A/BEA/EB) Valve model b Cv b Cv 15 17 21 15 17 21 16 18 22 16 18 22 3 8 1 2 3 4 3 8 1 2 3 4 3 8 1 2 3 4 3 8 1 2 3 4 0.22 0.15 0.13 0.22 0.15 0.13 0.28 0.27 0.19 0.28 0.24 0.15 3.6 4.0 5.2 3.6 4.0 5.2 4.0 4.7 5.3 3.9 4.5 5.1
If foreign objects with a size of 20 m or more are likely to enter, install the particle filter. 6 Filter Rc1/2 20m Note FQ1011N-04-T020-B-X61 Note) The filter shown above cannot be directly connected to the thermo-chiller.
Model C [dm3/(sbar)] C [dm3/(sbar)] Av x 10-6 m2 Cv converted Cv converted b Cv b Cv N.O. N.C. 0.12 0.03 0.35 0.03 0.72 1 M5 1/8 (6A) 0.04 0.13 0.96 VDW200 0.52 0.04 1 0.31 0.08 0.45 0.09 1.9 1.6 0.52 0.16 0.52 0.16 3.8 2 1.8 1/8 (6A) 1/4 (8A) VDW300 0.13 0.38 1.0 3.1 0.28 0.52 0.30 0.50 0.12 6.7 3 1.5 0.44 0.49 0.46 11 4 17-2-75 16 Series VDW200/300 Construction VDW250 VDW350 i o !0 i !
VDW 2 0 1 B 1 Series Lead wire length OUT (2) 1 2 3 10 20, 200 30, 300 300mm 600mm Nil L1 Note) Note) Type L1 is optional. (1) IN 2 port valve Voltage Type Note 1) Maximum operating pressure differential MPa (psi) 1 2 3 4 5 6 100VAC 200VAC 110VAC 220VAC 24VDC 12VDC Orifice size mm B C1 C2 20, 200 10, 30 300 Model Pressure port 2 Note 1) Pressure port 1 1 0.4 (58) 0.9 (130.5) VDW10 1.6 0.2
Disconnect the jumper wire from the remote terminal B (terminal number 6-7) and connect the switch. Automatic return switch (momentary switch).
If foreign objects with a size of 20 m or more are likely to enter, install the particle filter. 6 Filter Rc1/2 20m Note FQ1011N-04-T020-B-X61 Note) The filter shown above cannot be directly connected to the thermo-chiller.
EX) Base: 6 stations, common EXH, A & B port Rc 1/2 VVPA450-061-04 1 pc. VPA4154-00 3 pcs. VPA4254-00 2 pcs. XT038N-4A 1 pc.
Z A B . Oct X QX RX SX . ZX AX BX . T With stand for vertical installation 8 1 15 9 D-sub 15 pin (Socket type) Fixed screw: M2.6 Description No.