SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ5-41-02-M5"

M5 01 N01 Port size M5 x 0.8 R1/8 NPT1/8 Pressure-sensing part Silicon fluid contact Materials in Piping port (Common) PBT, CB156, heat resistant PPS, O-ring: HNBR part Piping port C3604 (Electroless nickel plating), SUS304, NBR Weight Body 24 g 34 g 36 g Lead wire with connector +39 g Cable specifications Conductor area 0.15 mm2 (AWG26) Insulator Outside diameter 1.0 mm Color Brown, Blue

M5 01 N01 C4H C6H N7H C4L C6L N7L Port size M5 x 0.8 R1/8 NPT1/8 4 mm One-touch fitting Straight type 6 mm 1/4 inch 5/32 inch 4 mm One-touch fitting Elbow type 6 mm 1/4 inch 5/32 inch Pressure-sensing part Silicon Materials in fluid contact Piping port (Common) PBT, CB156, heat resistant PPS, O-ring: HNBR C3604 part (Electroless nickel Piping port POM, SUS304, NBR, C3604 plating), SUS304,

41 0 0 1.5 2 2 5.5 4 4.5 8 31.5 35.5 43 31.5 35.5 43 Note) The above values should be used as a guide for detection at stroke end.

Weight [g] D-M9N(V) D-M9P(V) D-M9B(V) Auto switch model Caution 0.5 8 8 7 Precautions 1 14 14 13 Lead wire length (m) 3 41 41 38 Fix the auto switch with the existing screw installed on the auto switch body.

The straight piping length shall be 8 cm or longer in order to maintain 3%F.S. of the specification. -70No.PF-OMO0005-F Dimensions (in mm) PFMB7201-02 PFMB7201-N02 -71No.PF-OMO0005-F PFMB7201-02L PFMB7201-N02L -72No.PF-OMO0005-F PFMB7201S-02 PFMB7201S-N02 -73No.PF-OMO0005-F PFMB7201S-02L PFMB7201S-N02L -74No.PF-OMO0005-F PFMB7201-F02 -75No.PF-OMO0005-F PFMB7201-F02L -76No.PF-OMO0005-F PFMB7201S-F02

) (2)2mm 2 D (3) 40 30mm 50mm ()60mm 0mm 16 *LEH 10mm 25 30mm 30mm 50mm DIN 60mm 17 - 4 4.1 Node Address/Data Rate 1 DeviceNet MSD LSD Data Rate *1 PGM DeviceNet *2 010 *3 PGM DeviceNet Node Address MSD LSD Data Rate Node Address Data Rate MSD LSD 0 125kbps 10) 1) 1 250kbps 0 0 0 2 500kbps 0 1 1 3 PGM *1 0 2 2 9 6 2 62 6 3 63 6 4 PGM *1 9 9 2 PGM 64-99 01h MAC ID 063 02

For how to enter the security code, refer to "How to enter the security code" on page 41. 4, If the security code entered is correct, the display will change to UnL. Press any of the , or buttons to release the key lock and return to measurement mode. If the security code entered is incorrect, FAL will be displayed and the security code must be entered again.

Clear Water (as Circulating Water) Quality Standards The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulating type Supply water Influence Item Unit Standard value Corrosion Scale generation p p p p p p pH (at 77F (25C)) 6.0 to 8.0 100to 300 Electrical conductivity (77F) [S/cm] Standard item Reference item Chloride ion (Cl) [mg/L]

RoHS 3-Screen Display High-Precision Digital Pressure Switch: For Air ISE70/71 Series How to Order ISE70 02 M L2 Pressure range Option 3 Symbol Description ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certicate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/41 T Calibration certicate Option 2 Symbol

Namur mounting allows for installation between the Actuator and SMC PPS Body Solenoid Valve or on a Delrin Sub-base 41 23.5 3. Will help reduce "water hammer" by throttling the actuator speed allowing for more precise Actuator control 2xDUCK-BILL CHECK VALVE (3/5 PORT) 4. Stainless Steel adjustment screws PORT 1 PORT 3 5.

How to order HF2BFB 30 02 (1) (2) (3) (4) (5) (2) Symbol Details Body size 30 40 BFA Antibacterial Filter (5m) BFB Antibacterial Filter (0.1m) (1) Filter type BFC Odor Removal Filter BFD Bacteria Removal Filter Nil Rc N NPT (3) Thread type F G 02 1/4 (4) Port size 03 3/8 04 1/2 Nil Flow direction: left to right (5) Semi-standard R Flow direction: right to left 10 5.

(Refer to page 41 for details.) -40No.PS-OMX0002-A Auto-preset When auto-preset is selected in function selection mode, the set value can be calculated and memorized from the measured pressure.

N Options Hand valve R In/Out Reverse Valve model (Cv) Port size (NPT) 2 3 4 6 (0.4) (1.1) (3.2) (10.5) 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Porting and mounting method Code 0 1 2 3 Mounting method Body Panel mount Body Panel mount Note) Only side porting is available for VH200 and VH600 and R port is located on the bottom.

Filtration rating . 0.3 I' m 0.01 I'm 0.3+0.01 I'm Oil misl removal rate : O.8ppm (1.0mglm3(ANR)} O .08ppm (O.1 mg/m3(ANR)) 008ppm (O.1 mglm3(ANR)) Micro-Mist Separator with Prefilter Micro-Mist Separator SeriesAMH Available Models Model AMH150 AMH250 AMH350 AMH450 AMH550 AMH650 AMH850 Air flow rate NOle) Q/min (ANR) 200 500 1000 2000 3500 6000 12000 1/4 3/8 1/2 3/8 1/2 3/4 1/2 3/4 1 3/41

AP100-02 500 Relief flow {l/min (ANR)} Dimensions 400 28 300 Panel cut dimensions 200 100 + 0 K P C U O 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S L H 32.5 Set pressure (MPa) Note) The graph above shows the relief flow when the set pressure rises and falls from 0.1 MPa. 30 1.6 41 8.5 6.5 10 (69) 45.5 OUT IN 20 40 2 x 1/8, 1/4 40 758

Mesh: 100/70/50/25 mesh How to Order WF300 02 Port size Mesh 02 Rc1/4 03 Rc3/8 04 Rc1/2 Nil 100 mesh 1-X204 70 mesh 2-X204 50 mesh 3-X204 25 mesh Related Equipment Check Valve INA-14-290/XTO-674Water Regulator WR110--X224/WR110--X215 Body material: Brass Body material: Special brass Best Pneumatics 14-E627 Port size Set pressure range (-X224): 0.08 to 0.39 MPa Rc1/8, Rc1/4 Set pressure

CL Bore size (mm) 20, 25, 32 40, 50, 63 80, 100 Thread size Pulling force Stroke (mm) MLGC M2.5 X 0.45 X 25l 4.9N 2 M3 X 0.5 X 3l 10N 3 CNA M5 X 0.8 X 40l 24.5N 3 Bolt should be detached under normal operation, otherwise it may cause malfunction of the locking feature. CB wThe lock piston is pushed further upward.

C J G5-S Material: Carbon steel Material: Polyurethane (mm) (mm) (mm) CV MM A B M16 x 1.5 M20 x 1.5 M25 x 1.5 M30 x 1.5 M32 x 1.5 B 3.5 4.5 5 6 6.6 C 22 27 32 41 41 h1 25.4 31.2 37 47.3 47.3 C 4 8 8.3 11.3 13.1 h M16 x 1.5 M20 x 1.5 M25 x 1.5 M30 x 1.5 M32 x 1.5 MM B 6 6 6 6 6 C 22 27 32 41 41 Part no. Part no. Part no.

CL MLG Stroke (mm) Pulling force Bore size (mm) 20, 25, 32 40, 50, 63 80, 100 Thread size CNA 2 4.9N M2.5 X 25l 3 10N M3 X 3l CNG 3 24.5N M5 X 40l Bolt should be detached under normal operation, otherwise it may cause malfunction of the locking feature. MNB wThe lock piston is pushed further upward.