3 I.D. 10.8 x 2.4 O-ring JIS B2401-4D-P11 FPM 4 Series FQ1 Dimensions Bracket 32 V-band support 2.3 75 (25) 50 100 (80) 75 70 70 30 50 10 92 7 2-A 10 108 R3.5 R8 127 (60) R25 120 109 Part number A Applicable bore size Rc 1 Rc 3/4 Rc 1/2 BP-13S BP-14S BP-15S 34.5 27.5 22 120 50 AIR VENT 10 G1/4 10 92 7 R3.5 2-Rc P 102 (43) A I N INLET OUTLET B (108) Intermediate holder Note) Installed only

Symbol x 50 001 005 010 020 050 075 100 002 004 006 013 0.01 0.01 0.005 0.005 0.002 5 10 50 100 0.002 10 50 100 Flow rate l/min (ANR) Flow rate l/min (ANR) Note) The recommended flow rate is the rate for an initial pressure drop of 0.01 to 0.02 MPa. 2 Series FQ1 How to Order Filters Element and Seal Part Numbers 1.

Operating: 0 to 50C, Stored: 10 to 60C (with no freezing and condensation) Resistance Operating or Stored: 35 to 85%RH (with no condensation) 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller.

From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm). Then, the actuator should move from the position where the pushing operation was completed (where INP turned ON) to a point 50 mm away at 50 mm/s. (Step Data No.2 is used for this operation).

3150 L/min 60 to 6300 L/min 120 to 12600 L/min Set point range Accumulated flow 0 to 999,999,999,990 L Instantaneous flow 2 L/min 5 L/min 10 L/min Flow Minimum resolution Accumulated flow 10 L 100 L Accumulated volume per pulse (Pulse width = 50 msec.)

M36 x 1.5 21 47 50 64 4 Compact Cylinder/ Double Acting: Double Rod Series CQ2W 180, 200 How to Order CQ2WB 180 180 50 50 D D C C Z76 With Auto Switch CDQ2WB With auto switch (built-in magnet) Number of auto switches 2 pcs. Nil S 1 pc. n "n" pcs.

3 I.D. 10.8 x 2.4 O-ring JIS B2401-4D-P11 FPM 4 Series FQ1 Dimensions Bracket 32 V-band support 2.3 75 (25) 50 100 (80) 75 70 70 30 50 10 92 7 2-A 10 108 R3.5 R8 127 (60) R25 120 109 Part number A Applicable bore size Rc 1 Rc 3/4 Rc 1/2 BP-13S BP-14S BP-15S 34.5 27.5 22 120 50 AIR VENT 10 G1/4 10 92 7 R3.5 2-Rc P 102 (43) A I N INLET OUTLET B (108) Intermediate holder Note) Installed only

200 300 300 200 Usable range 100 100 Usable range 20 30 40 50 50 40 30 20 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Distance from cylinder shaft center: L0 (cm) Distance from cylinder shaft center: L0 (cm) Note: 1N = 0.2248lbf 1kg = 2.2046lb 1in = 25.4mm 1in = 2.54cm 100 80 REA63 REA50 50 40 30 REA40 REA32

Specification for Option M 10 1 Safety instructions . 10 1 10 2 Specifications . 10 2 10 3 Installation of motor type auto drain . 10 3 10 4 Electric circuit . 10 3 Chapter 11 Specification for Option R 11 1 Safety instructions . 11 1 11 2 Specifications . 11 1 11 3 Power supply connection procedure . 11 2 11 4 Cautions for handling the GFCI . 11 3 11 5 Electric circuit . 11 3 Chapter 12

less 31 49 37 5 or less 20 190 35 62 50 10 or less 39 66 33 5 or less 30 190 39 68 43 10 or less 43 72 29 5 or less 50 190 49 83 33 10 or less 53 87 22 5 or less 70 190 54 95 30 10 or less 58 99 21 5 or less 100 190 61 108 27 10 or less 65 112 18 5 or less 200 190 81 139 21 10 or less 85 143 15 5 or less Operating range m: Value of the operating range Lm of a single auto switch converted

From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm). Then, the actuator should move from the position where the pushing operation was completed (where INP turned ON) to a point 50 mm away at 50 mm/s. (Step Data No.2 is used for this operation).

Rated voltage 3 2 1 110 VAC 50/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Model Port size (Rc 1/4) (Rc 3/8) (Rc 1/2) (Rc 3/4) (Rc 1) 02 03 04 06 10 2232 2232 2242 2352 2362 4 5 6 7 8 9 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC for inquiry.) Refer to the table (1) given below for availability. Refer to page 17-3-65 for ordering a coil only.

Indicator light Output 1 and 2: Orange Power supply voltage 12 to 24 VDC 10% Current consumption 50 mA max. Enclosure IP65 Operating temperature range 0 to 50 oC (No freezing and condensation) Environment Operating humidity range Operation, Storage: 35 to 85%R.H.

Graph (2) Cylinder Output on the Retracting Side (Double acting) 1500 150 Tube bore size [mm] 1000 100 40 Side load Balance weight 400 500 40 50 32 200 250 300 20 25 30 Operating pressure [MPa] Cylinder output F[N] Load weight [kg] 150 15 Allowable Side Load on the Piston End (Nm) 100 10 Stroke of linear part Size 40 40 50 4 5 100 75 50 40 30 25 20 15 10 5 32 32 40 9 10 11 12 12 13 13 13

A L D VQZ D KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 VQD Color: White VZS VFS EXH port silencer VS 63 Silencer is installed in the EXH port.

Ph (25C) 6.5 to 8.2 6.0 to 8.0 Electrical conductivity (25C) (s/cm) * 100 to 800 0.5 to 300 Chloride ion (mgCl-/L) Max. 200 Max. 50 2-/L) Max.200 Max.50 Sulfate ion (mgSO4 Acid consumption (Ph4.8) (mgCaCO3/L) Max.100 Max.50 Total hardness (mgCaCO3/L) Max.200 Max.70 Calcium hardness (mgCaCO3/L) Max.150 Max.50 Standards Ionic silica (mgSiO2/L) Max.50 Max.30 Iron (mgFe/L) Max.1.0 Max.0.3 Copper

Electrical entry Normally closed Normally open Double acting VNA01 VNA02 VNA03 VNB Coil rated voltage (V) AC (50/60 Hz) 100 V, 200 V, Other voltage (Semi-standard) 24 V, Other voltage (Semi-standard) 15% to +10% of rated voltage 35C or less (When rated voltage is applied.) 5.6 VA (50 Hz), 5.0 VA (60 Hz) 3.4 VA (50 Hz), 2.3 VA (60 Hz) 12.7 VA (50 Hz), 10.7 VA (60 Hz) 7.6 VA (50 Hz), 5.4 VA

VV3ZA2-50-031-01 1 pc. VV3ZA4-50-031-021 pc. VZA214-P2 pcs. VZA414-2P2 pcs. VVZ200-31A-11 pc.

40 55 9 18 7 50 65 1/4, 3/8, 1/2 AC40B-06-D 1/8 155.2 149.1 35.5 38.4 77.6 40 35.5 0 50 40 55 9 18 7 50 65 3/4 AC50B-D 1/8 186.2 220.1 43 38.4 93.1 30 45 0 70 50 70 11 20 8 60 80 3/4, 1 AC60B-D 1/8 196.2 234.1 45 38.4 98.1 30 45 0 70 50 70 11 20 8 60 80 1 Options Semi-standard specifications Metal bowl with Digital level gauge With PC/PA bowl Metal bowl Square Round type Round type Round

AC VXR21 DC 50 45 20 60 40 15 AC VXR22 DC 50 60 25 60 50 20 AC VXR23 DC Operating Fluid and Ambient Temperature Operating fluid temperature (C ) Ambient temperature (C ) Temperature conditions Power source Water (Standard) Oil (Standard) High temperature oil (2) High temperature water (2) (D) (D) 80 80 40 60 AC DC AC/DC 60 40 1 60 40 Maximum Minimum 10 5 (1) Note 1) 50 cSt or less Note