6, 10, 15, 20, 25, 32 Dual Rod Cylinder Series CXS 10-/11-/1221-/22Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Directional Control Valves Air Grippers Modular F. R.
F: FKM E: EPDM For VCB30 OR-2380-130F F: FKM E: EPDM For VCB40 OR-2600-180F F: FKM E: EPDM If external leakage occurs after replacing the coil, replace the above seals. When the loosened clip is pulled out in direction using pinchers, etc., the coil can be removed and replaced in direction .
If a Wireless Remote unit with inputs / outputs which are different from the set numbers is registered, the I/O map should be changed. -85No.EX##-OMV0017-D (5)-f FCS Setting (Frequency Channel Select The frequency channel can be selected using this function. This function is only supported by protocol V.2.0. Specify protocol V.2.0 in [System setting].
PF3W5--2 (Analogue 4 to 20 mA type: Without temperature sensor) Flashes three times.
How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)
type (2 fingers) Series LEHF S type (3 fingers) Series LEHZ Series LEHS Opening/closing stroke Opening/closing stroke 4 6 10 14 22 30 Opening/closing stroke 4 6 8 12 Opening/closing stroke 16 (32) 24 (48) 32 (64) 40 (80) Size Size Size Size 10 20 32 40 10 20 32 40 10 16 20 25 10 16 20 25 32 40 4 6 10 14 CAT.NAS100-77 Controller Step data input type for servo motor Programless type Step data
Applicable bore size d H B C D E1 C H NX B A L1 A1 U1 I-04A 40 69 22 24 55 M14 x 1.5 15.5 20 12+0.070 0 16 0.1 0.3 I-05A 50, 63 74 27 28 60 M18 x 1.5 15.5 20 12+0.070 0 16 0.1 0.3 I-08A 80 91 37 36 71 M22 x 1.5 22.5 26 18+0.070 0 28 0.1 0.3 I-10A 100 105 37 40 83 M26 x 1.5 24.5 28 20+0.084 0 30 0.1 0.3 NT-04 40 M14 x 1.5 8 22 25.4 21 NT-05 50, 63 M18 x 1.5 11 27 31.2 26 NT-08 80 M22 x 1.5
Other parameter settings Item Page Default setting [F 3] Response time page 30 2.5 ms [F 4] Display resolution page 31 1000-split [F 5] Auto-preset function page 32 Manual [F 6] Fine adjustment of display value page 34 0% [F 7] Power saving mode page 35 OFF [F 8] Security code page 36 OFF [F90] Setting of all functions page 37 OFF [F97] Copy function page 39 OFF [F98] Check of output page
Refer to Flow Characteristics (page 14-20-44) and figure of Max. Air Flow (page 14-20-45).
0 Units selection function 30 F 1 Setting of OUT1 31 F 2 Setting of OUT2 34 F 3 Digital filter setting 36 F 4 Auto-preset function 37 F 5 FUNC terminal setting 39 F 6 Fine adjustment of display value 40 F10 Sub display setting 41 F11 Display resolution setting 47 F14 Zero cut-off setting 48 F80 Power saving mode 49 F81 Security code 50 F90 Setting of all functions 52 F96 Number of pressurizing
AW-OMX0057-A PRODUCT NAME Filter Regulator MODEL / Series / Product Number AW20(K)-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AW30(K)-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW40(K)-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW40(K)-(F,N)06(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW60(K)-(F,N)06(F,N)10(B,C,
(Figure-20-3) Fix the cylinder with screws included as accessories after confirming that there is no interference between the lever and the proximity switch. Figure-20-1 Figure-20-2 Figure-20-3 20 - 9. Troubleshooting Detail of trouble Cause Countermeasure Operation is not smooth 1. Lubrication failure Clean components and apply specified grease to them. 2.
N] F=-q x PA+w x PC F=q x PA+(e-q) x PC F=-q x PA+r x PB+(w-e) x PC F=q x PA q, w and e are piston areas.
Series MHZ2 112210, 16, 20, 25 Air Gripper How to Order 11 Vacuum suction type Clean series 11 MHZ2 16 D M9N 22 MHZ2 16 D M9N Copper, fluorine and silicone-free + Low particle generation Bore size 10 16 10 mm 16 mm 22 Vacuum suction type 20 mm 20 25 mm 25 Action Number of auto switches Double acting D Nil 2 pcs. S 1 pc.
2110 20 21Direct Operated Precision Regulator (For Special Applications) Direct Operated Precision Regulator with Backflow Function (For Special Applications) Series ARP20K to ARP40K 10 20 2110 20 21-ARP20/ARP20K 10 20 21 -ARP30/ARP30K 10 20 21 -ARP40/ARP40K 10 20 21 Description Symbol Body size 20 30 40 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting
Setting Mode 24 Function Selection Mode 26 Function selection mode 26 Default setting 26 F 0 Units selection function 28 F 1 Setting of OUT1 29 F 3 Digital filter setting 32 F 4 Auto-preset function 33 F 6 Fine adjustment of display value 35 F10 Sub display setting 36 F11 Display resolution setting 41 F80 Power saving mode 42 F81 Security code 43 F82 Input of line name 45 F90 Setting of all
Approx. 300 F Q Q Class H coil Broken line section C C G 1/2 R R E E A H A H B B 2-P Port size 2-P Port size 2-M, thread depth N 2-M, thread depth N L L K K DIN terminal: D Conduit terminal: T Cable 6.8 to 10 F S Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet: G Conduit: C DIN terminal
F Analog 4 to 20 mA G External input Note 4) H External input Note 4) Note 4) Accumulated flow, peak flow Unit specifications and minimum flow can be reset by external signal input.
Field name Example RTU mode ASCII mode (HEX) character data binary data Header : None Device address 0x01 0,1 0x01 Function 0x04 0,4 0x04 Quantity of bytes to read 0x02 0,2 0x02 Information of 0009h(Data display 1) 0x00FA 0,0,F,A 0x00,0xFA Checksum ASCII:LRC RTU:CRC F,F 0x39,0x73 Trailer CR/LF None Total quantity of byte 15 7 * Response message at an ambient temperature of 25.0C 3.13 Register
AF-OMR0020-C PRODUCT NAME MIST SEPARATOR MODEL / Series / Product Number AFM20-(F,N)01(F,N)02(B,C)(-2,6,C,J,R,Z)-A AFM30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,R,W,Z)-A AFM40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,R,W,Z)-A AFM40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-A Contents Page 1. SAFETY INSTRUCTIONS 1-5 2. APPLICATION 6 3. SPECIFICATIONS 6 4. HOW TO ORDER 7 5. OPTIONAL BRACKET ASSEMBLY 8 6.