SMC Corporation of America
Elite Part Number Search
Search Results "LQ3H4A-T-1"

1-1/8 1-1/4 1-3/8 1-1/2 1-5/8 1-7/8 2-1/8 2-3/8 2-5/8 3-1/8 3-5/8 4-1/8 4-5/8 #6-32UNC3/4 7/8 1 1-1/8 1-1/4 1-3/8 1-1/2 1-5/8 1-7/8 2-1/8 2-3/8 2-5/8 3-1/8 3-5/8 4-1/8 4-5/8 #6-32UNC1-1/8 1-1/4 1-3/8 1-1/2 1-5/8 1-3/4 1-7/8 2 2-1/4 2-1/2 2-3/4 3 3-1/2 4 4-1/2 5 #10-24UNC1-1/8 1-1/4 1-3/8 1-1/2 1-5/8 1-3/4 1-7/8 2 2-1/4 2-1/2 2-3/4 3 3-1/2 4 4-1/2 5 #10-24UNC1-1/4 1-3/8 1-1/2 1-5/8 1-3/4 1

HRX-OM-W060 Contents Contents Chapter 1 Safety Instructions . 1-1 1.1 Before Using the Product . 1-1 1.2 Reading the Manual . 1-1 1.3 Hazards . 1-2 1.3.1 Level of hazards . 1-2 1.3.2 Definition of Serious injury and Minor injury . 1-2 1.4 Product Label . 1-3 1.5 Safety Measures . 1-4 1.5.1 Safety instructions for use . 1-4 1.5.2 Personal protective equipment . 1-4 1.6 Emergency Measures.

[] (1) ():1 ():1 Undefined No.11 1 4096 X 800 1 (2) ():1 ():2 1600 1 (3) ():2 ():1 400 1 ):1 ():1 01 40974096 1 1 [] 1 LEY16C-300 2.5mm 1/1 2 LEY16B-300 5mm 25/50 3 LEY16A-300 10mm 25/100 1 800 2.5mm Undefined No.12 1 4096 X 2 3 =1 /2 (3 ) =2.5mm/5mm (2.5mm/10mm) =25/50 (25/100) 1 -50No.JXC-OMT0001CN-C 9.3 XX X () 1:CW 2:CCW X ORIG direction 1 2 1 2: XX ORIG

HRX-OM-R005 Contents Contents Chapter 1 Safety Instructions . 1-1 1.1 Before using the product . 1-1 1.2 Reading the Manual . 1-1 1.3 Hazards . 1-2 1.3.1 Level of hazards . 1-2 1.3.2 Definition of Serious injury and Minor injury . 1-2 1.3.3 Types of hazard labels . 1-3 1.3.4 Locations of Hazard Labels . 1-4 1.4 Other Labels . 1-5 1.4.1 Product Label . 1-5 1.4.2 Earth Label . 1-5 1.5 Safety

(A) 2 1 (P) 3 (R) Rubber seal type VQZ200 300 / Metal seal type 3 2 1 3 2 1 N.C. N.C. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) 3 2 1 3 2 1 N.O. (A) 2 N.O. (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Parts list No.

1) (Note 1) 31 Overspeed 32 Overcurrent Alarms 33 Overvoltage 34 Receive error 1 (Note 2) 35 Command frequency error 36 Receive error 2 37 Parameter error 45 Main circuit device overheat (Note 1) (Note 1) (Note 1) 46 Servo motor overheat (Note 1) (Note 1) (Note 1) 47 Cooling fan error 50 Overload 1 (Note 1) (Note 1) (Note 1) 51 Overload 2 (Note 1) (Note 1) (Note 1) 52 Error excessive 8A USB

CE*-OMQ0013-F / / 1 7 1-1 1-2 1-3 1-4 8 2-1 2-2 2-3 13 3-1 3-2 3-3 15 4-1 4-2 4-3 17 5-1 5-2 5-3 21 6-1 6-2 22 7-1 7-1-1 7-1-2 7-2 7-2-1 7-2-2 7-3 7-3-1 7-3-2 7-3-3 INPUT 7-3-4 OUTPUT 7-3-5 7-3-6 28 36 9-1 9-1-1 9-1-2 9-1-3 9-2 9-2-1 9-2-2 9-3 9-3-1 45 10-1 10-2 46 11-1 11-2 50 12-1 CE2/CEU2 / *1) (ISO/IEC)(JIS) *2) *1) ISO 4414: Pneumatic fluid power

1 !9 !0 i !4 o !8 q @0 !2 e !3 !5 MX MTS t !6 r u y w !

Metal seal Rubber seal (1) Without (1) (1) With Function (1) With (w/o light) Symbol Specification DC (1.0W) AC Note 1) DIN style is applicable to VQ2000, 3000.

(Inch) 1/8" x 0.086" 1/8" 1/8" x 1/16" 3/16" 3/16" x 1/8" 1/2" 1/2" x 3/8" 3/8" 3/8" x 1/4" 1/4" 1/4" x 5/32" Refer to Best Pneumatics No. 7 for further details. 13 Series PB Applicable Fluids Material and Fluid Compatibility Check List for Process Pumps The data below is prepared based on data provided by the material manufacturers.

to 12 stations 24 D side D-sub connector kit P kit Note 1) 1 to 12 stations 24 D side 16 stations 26P 20P 1 to 9 stations 18 Flat ribbon cable connector kit J kit Flat ribbon cable (20P) PC wiring system compatible JD0 D side 1 to 8 stations 16 stations 16 Flat ribbon cable (20P) (PC Wiring System compatible) T kit TD0 Terminal block box kit D side 1 to 10 stations 16 stations 20 Terminal

2) Note 2) Note 1, 2) Note 1, 2) Note 1, 2) 1.

Mounting hole T(M) L1 L2 Nylon Urethane 1 8 KGE04-01 16 35 25 40 29 14 16 27.5 31 28 31.5 33.5 27.5 33 11 15 11 15 17 7.5 13 4 M12 1 13 5.6 5.6 14 1 4 KGE04-02 17 1 8 1 4 3 8 1 8 KGE06-01 KGE06-02 KGE06-03 KGE08-01 17 6 M14 1 13.1 13.1 17 15 17 19 26.1 18.0 28 27 48 17 1 4 KGE08-02 M16 1 8 18.5 17 19 3 8 KGE08-03 15 19 35 1 4 KGE10-02 34.5 36.5 41.5 29.5 53 67 12.5 14 10 21 M20 1 21 22 24

Mounting hole T(M) L1 L2 Nylon Urethane 1 8 KGE04-01 16 35 25 40 29 14 16 27.5 31 28 31.5 33.5 27.5 33 11 15 11 15 17 7.5 13 4 M12 1 13 5.6 5.6 14 1 4 KGE04-02 17 1 8 1 4 3 8 1 8 KGE06-01 KGE06-02 KGE06-03 KGE08-01 17 6 M14 1 13.1 13.1 17 15 17 19 26.1 18.0 28 27 48 17 1 4 KGE08-02 M16 1 8 18.5 17 19 3 8 KGE08-03 19 15 35 1 4 KGE10-02 34.5 36.5 12.5 14 41.5 29.5 53 67 10 21 21 M20 1 22 24

3 @1 @3 @2 e o !8 @7 #0 !7 @6 r u #1 t @4 @5 #2 @0 y i !9 !0 q !1 w !

CAT.ES100-41 A Multi-Channel Controller Series PSE200 Pressure Sensor Series PSE530 1 A single controller monitors up to 4 pressure sensors. 2 4 MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE SET 3 1 A single controller monitors 2 4 MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE SET 3 Multi-Channel Controller Series PSE200 Pressure Sensor Series PSE530 Space saving 1 40mm MPa kPa OUT1 76% OUT2 CH 1 2 3 4 PRESSURE

Proper tightening torque N.m Nominal thread size 1/6 rotation after tightening by hand M5 13.6N.m R 1/4, NPT 1/4, G 1/4, URJ 1/4, TSJ 1/4 3. Apply wrench only to the metal part of the main housing when installing the pressure switch onto the system piping.

(mm) 2(A) Port size R(PT) 2(A) Port size R(PT) 1(P) 1(P) 1(P) 4 6 8 10 12 M5 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 4 6 8 10 12 1(P) M5 M5 4 M5 4 Tube O.D. (mm) Tube O.D.