Controller Series: LECP1 (Programless Controller), Parallel I/O Type: P (PNP), I/O Cable Length, m: 5, Option: Screw Mounting, Actuator Series: LER (Rotary Table), Table Accuracy: Basic, Size: 50, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6)
Controller Series: LECP1 (Programless Controller), Parallel I/O Type: P (PNP), I/O Cable Length, m: 5, Option: Screw Mounting, Actuator Series: LER (Rotary Table), Table Accuracy: H (High Precision), Size: 30, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6)
Controller Series: LECP1 (Programless Controller), Parallel I/O Type: P (PNP), I/O Cable Length, m: 5, Option: Screw Mounting, Actuator Series: LER (Rotary Table), Table Accuracy: Basic, Size: 10, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10)
Controller Series: LECP1 (Programless Controller), Parallel I/O Type: P (PNP), I/O Cable Length, m: 5, Option: Screw Mounting, Actuator Series: LER (Rotary Table), Table Accuracy: H (High Precision), Size: 50, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10)
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: 5, Option: Screw Mounting, Actuator Series: Rotary Table, Table Accuracy: Basic, Size: 30, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: -
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: 5, Option: Screw Mounting, Actuator Series: Rotary Table, Table Accuracy: Basic, Size: 30, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: -
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: 5, Option: Screw Mounting, Actuator Series: Rotary Table, Table Accuracy: High Precision, Size: 30, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: -
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: 5, Option: Screw Mounting, Actuator Series: Rotary Table, Table Accuracy: Basic, Size: 10, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: -
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: 5, Option: Screw Mounting, Actuator Series: Rotary Table, Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: -
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: 5, Option: Screw Mounting, Actuator Series: Rotary Table, Table Accuracy: High Precision, Size: 30, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: -
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: 5, Option: Screw Mounting, Actuator Series: Rotary Table, Table Accuracy: Basic, Size: 10, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: -
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: 5, Option: Screw Mounting, Actuator Series: Rotary Table, Table Accuracy: High Precision, Size: 50, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: -
bytes occupied Output data: [Unit 0] Digital output unit (EX600-DYB): 1 byte occupied [Unit 2] Wireless Base unit (EX600-WEN#): 2 bytes occupied Unit 0 Unit 1 Unit 2 Unit 3 DYB AXA DXD EX600-WSV# Wireless Remote unit setting parameter (Wireless channel 001) Valve End Digital output Analogue Digital Wireless manifold plate input input Remote unit Input size: 64 points/8 bytes Output size: 48
bytes occupied Output data: [Unit 0] Digital output unit (EX600-DYB): 1 byte occupied [Unit 2] Wireless master unit (EX600-WEN#): 2 bytes occupied Unit 0 Unit 1 Unit 2 Unit 3 DYB AXA DXD EX600-WSV# Wireless slave unit setting parameter (Wireless channel 001) Valve End Digital output Analogue Digital Wireless slave manifold plate input input unit Input size: 64 points/8 bytes Output size: 48
Table for the change of parameter setting (wireless slave (1)) Setting items Set value Hold/Clear (unit) Clear Occupied points for the module input 64 point/8 byte Occupied points for the module output 48 points/6 bytes Occupied points for the valve manifold output 32 point/4 byte Wireless communication Active Analogue input update time 1 s I/O unit assignment direction Mode 1 (4) (3) Default
bytes occupied Output data: [Unit 0] Digital output unit (EX600-DYB): 1 byte occupied [Unit 2] Wireless master unit (EX600-WEN#): 2 bytes occupied Unit 0 Unit 1 Unit 2 Unit 3 DYB AXA DXD EX600-WSV# Wireless slave unit setting parameter (Wireless channel 001) Valve End Digital output Analogue Digital Wireless slave manifold plate input input unit Input size: 64 points/8 bytes Output size: 48
*Operating delay time of the valves is not considered 48 No.EX##-OMY0011-A Appendix F: Failure modes The function of the product is to safely control the switching off of the attached pneumatic valves. Hazards and harmful events that could compromise this function need to be responded to as defined below.
No.EX-OMN0035CN-A / Series EX600-DX## EX600-DY## EX600-DM## SMC 3 9 10 12 12 14 17 17 20 20 LED 25 28 28 31 34 34 36 36 LED 40 42 42 44 46 46 48 48 LED 52 54 54 56 -1No.EX-OMN0035CN-A 57 58 58 58 58 58 59 -2No.EX-OMN0035CN-A (ISO/IEC)(JIS) 1 2 *1 ISO 4414: Pneumatic fluid power -General rules relating to systems.
(Refer to "Sub display" on page 48.) The corrected value [C_5] after auto-shift input will disappear when the power is turned off, and will reset to zero (initial value) when the power is returned.
Measurement mode] 25 Flow Setting (set value only) of OUT1 OUT2 [3 step setting mode] 26 Default settings 28 Function Setting [Function selection mode] 28 Default settings 28 F0 Reference condition Unit selection function 29 F1 Setting of OUT1 31 F2 Setting of OUT2 39 F3 Response time 44 F10 Display mode 45 F13 Reversed display mode 46 F20 External input 47 F22 Setting of analogue output 48