Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) AS TMH ASD AS Number of needle rotations Number of needle rotations Number of needle rotations AS-FE KE Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa AS-FG Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) AS-FP AS-FM AS-D AS-T AS-D AS-T ASP Number

A B 63 63 80 85 90 100 C Port size Rc(PT) INA-11-402 INA-11-403 INA-11-404 INA-11-405 INA-11-406 INA-11-407 Model No. 1/4 15 15 15 20 22 22 141 164.5 170 180 230 251 3/8 1/4 , 3/8 , 1/2 3/4 B C D E F Port size Rc(PT) 3/4 , 1 1 Model No. A 1 2 150 165 42.7 76.3 45 65 40 60 35 40 80 80 ALBA90-10 ALBA90-20 1.17-24

L ISA-5-1 ISA-5-2 ISA-5-3 ISA-5-4 ISA-5-5 ISA-5-6 ISA-5-7 L 73.0 8 4.5 1.25 7.5 135.5 173.0 210.5 248.0 5.5 35 35 285.5 323.0 852 Pressure Sensor Controller Series PSE200/300 Function Details A Auto-shift function B Auto-preset function When there are large fluctuations in the supply pressure, the switch may fail to operate correctly.

Single acting retraction type Features 2 Heavy Duty Stopper Cylinder Series RSH/RS1H 20, 32 50, 63, 80 How to Order Positional relationship of lever and port Piping direction Flange side RSH20 Port Direction of transfer Nil Nil RSH32 Direction of transfer Cylinder stroke Bore size Port 15mm (RSH20) 20mm (RSH32) 20mm 32mm 20 32 15 20 Heavy Duty Stopper Cylinder 20, 32 20 32 Z73 D L RSH Heavy

14 10 210.5 200 181 15 11 223 212.5 191.5 16 12 235.5 225 202 17 13 248 237.5 212.5 18 14 248 237.5 223 12.5 15 260.5 250 233.5 13.5 16 273 262.5 244 14.5 L1 L2 L3 L4 External pilot manifold L: Dimensions n: Stations (n1 + n2) L n 2 135.5 125 107.5 14 3 148 137.5 118 15 4 160.5 150 128.5 16 5 173 162.5 139 17 6 173 162.5 149.5 12 7 185.5 175 160 13 8 198 187.5 170.5 14 9 210.5 200 181 15

Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM Operating pressure Port size Rated flow rate Model Model/Rated Flow Rate Rated flow rate (L/min) Model Threaded connection Flange connection Port size Operating pressure Threaded connection Flange connection Threaded Rc Flange SSA Threaded Rc Flange SSA (L/min) FH340-03 FH340-04 FH342-06 FH342-08 FH340-10 FH340-12 FH540-03 FH540

Table 1 Table 2 Output type ON YES Hysteresis mode For air OFF P-1 P-2 Display Instantaneous flow rate l/min Cumulative flow rate l Large flow rate "P" H H H (fixed hysteresis) = 3 digits CFM x 10-2 ft3 x 10-1 ON CFM = ft3/min Window comparator mode NO OFF P-1 P-2 For water Large flow rate OUT1 Output mode Display Instantaneous flow rate l/min Cumulative flow rate l ON YES OUT2 is the

R C R C (44) G1/2 E A H 2-P Port size B (S) E G1/2 2-M Thread depth N D A H B 2-P Port size 2-M Thread depth N D L L K K N.O.

M4 x 5 L ZS-24-B Bracket B with 2 mounting screws M4 x 5 L ZS-24-D Bracket D with 2 mounting screws each of M3 x 5 L, M4 x 5 L ZS-35-C Panel mount adapter (piping specification: 01, N01) ZS-35-D Panel mount adapter (piping specification: W1, WF1, M5, C4, C6) ZS-35-F Panel mount adapter + Front protective cover (piping specification: 01, N01) ZS-35-G Panel mount adapter + Front protective

W Axial Right F R L T B Cable length Left Top 2m 3m 4m 5m 2 3 4 5 Motor specification Standard motor Matsushita Electric Industrial Co., Ltd.

0.3 0.3 P1 = 0.2MPa 0.2 0.2 P1 = 0.1MPa 0.1 0.1 0.001 0.04 0.03 0.02 0.01 0.004 0.003 0.002 0.1 Pressure difference P [MPa] Graph (2) Flow characteristics line Example 1) Obtain the pressure difference when water 15 [l/min] runs through the solenoid valve with an Av = 45 x 106 [m2].

43 L plug connector (L) n: Station Dimensions n L 11 12 13 14 15 16 17 18 19 28 20 39 31 50 42 61 53 72 64 83 75 94 86 105 97 116 108 127 119 138 130 149 141 160 152 171 163 182 174 193 185 204 196 215 207 20 237 229 2 3 4 5 6 7 8 9 10 L1 L2 1 226 218 1.13-10 Series VQD1000 Dimensions Plug lead manifold unit(VV4QD15-ll) Lead wire length: 300mm Light 4-Rc(PT)1/8 SY (P, R port) ACB ACB ACB

NVF353O f l Operating prs6sur range 2 pGiEon singb 20 -129 PSI S(1.5 -gkgF) 2 pssition double-15-128 P$l (1 -gkgflcm'?) Arntient and tluid temperatureMax .120'F(Max. 50'C) Respon time 2 poitl'| slngle/doubb 20ms or less at 75 PSI (skg/cm'?) 3 pcition 40ms or less at 75 PSI (skgf/cm'?)

10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 1/4" 6 12 3/8" 10 20 5/8" 15 40 3/4" 20 60 1" 25 80 32 1-1/4" 80 1-1/2" 40 80 2" 50 80 2-1/2" 63 80 Note) The longer the stroke, the larger the amount of deflection in a cylinder tube.

Start flag 0: no send Numerical data input 2 1: send 1 Step data No 0 to 63 Data writting 3 Operation Note) 1 1: Absolute 2: Relative 4 H 5 L Speed 2 0 to 65500 mm/s 6 3 7 2 Position 4 +/-2147483647 0.01mm 8 1 9 0 ID1 Numerical 10 H 11 L Acceleration 2 0 to 65500 mm/s2 data input 12 H 13 L Deceleration 2 0 to 65500 mm/s2 Data writting 14 Pushing force 1 0 to 30 10% 15 Trigger LV 1 0 to 30

Specifications .11 3. 1 Specifications.11 3. 2 Details of parts.13 3.3 Outside dimension diagram.14 (1) Screw mount type (LEC-GPR1).14 (2) DIN rail mount type (LEC-GPR1D) .14 3.4 How to install.15 (1) How to install.15 (2) Installation location .15 4. Initial Setting.16 4. 1. Switch (Address, B RATE).16 4. 2. Setting the switch to change the communication (CN2SW).17 4. 3.

Specifications .11 3. 1 Specifications.11 3. 2 Details of parts.13 3.3 Outside dimension diagram.14 (1) Screw mount type (LECGE1).14 (2) DIN rail mount type (LECGE1D).14 3.4 How to install.15 (1) How to install.15 (2) Installation location .15 4.

JIS symbol 1/8, 5/32 3/16, 1/4 3/8 5/16 3/16, 1/4 1/4 3/16 1/4, 5/16 1/2 Inch sizes 3/8 5/32 Flow rate l/min (ANR) {Nl/min} 920 660 230 420 1390 290 460 1050 100 130 Controlled (Free) Effective area mm flow 14 10 3.5 6.5 21 4.5 7 16 2 1.5 1l/min=0.035SCFM 18mm2=1Cv Note 1) Flow rate values are at a pressure of 0.5MPa (72.5psi) and temperature of 20C (68F).

Refer to Glossary on page 17-3-15 for details of max. operating pressure differential and max. system pressure.

L type) [00.50] 00.50 L/min (100 L type) [0.126] 0.126 L/min (250 L type) [ P_2] Set value (OUT2) Page 44 5% of maximum rated flow [00.20] 00.20 L/min (4 L type) [000.8] 000.8 L/min (16 L type) [002.0] 002.0 L/min (40 L type) [000.5] 000.5 L/min (100 L type) [00.12] 00.12 L/min (250 L type) [ H_2] Hysteresis (OUT2) Page 45 [ dtH2] Delay time setting at ON [ 0.00] 0.00 s Page 45 [ dtL2] Delay