These vortexes are stable under certain conditions, and their frequency is proportional to the flow velocity, resulting in the following formula. f = k x v f: Frequency of vortexes, v: Flow velocity, k: Proportional constant (determined by the vortex generator's dimensions, shape, etc.) Therefore, the flow rate can be measured by detecting this frequency.

19.2 k/45.45 k/ 93.75 k/187.5 k/500 k/ 1.5 M/3 M/6 M/12 Mbps 156 k/625 k/ 2.5 M/5 M/10 Mbps 125 k/250 k/ 500 kbps Communication speed 4-branch input Specified file Note 2) EDS file GSD file 64/64 Possible to change depending on the switch setting 96/96 (3 stations, remote device station) Possible to change depending on the switch setting Occupied area (Number of inputs/outputs) 4-branch

Indicator light Load voltage Auto switch model Lead wire length (m) Applicable load Pre-wired connector Tie-rod mounting Band mounting Special function Type Electrical entry Wiring (Output) 0.5 (Nil) 3 (L) 5 (Z) 1 (M) AC DC G39 K39 3-wire (NPN equivalent) M9N M9P J51 M9B M9NW M9PW M9BW M9NA M9PA M9BA F59F 3-wire (NPN) 3-wire (PNP) 24 V IC circuit 5 V, 12 V Grommet 100 V, 200 V 2-wire 12

Note 13) When option Y is selected, V for (4) exhaust sealing valve cannot be selected. -10No. ZKJ-OM00201-D 2.

area mm2 Note 1) D Model L Applicable tubing O.D. mm Weight g M 2-Applicable tubing TPH TPS KPH04-00 37.4 18 4 4 4 10.4 4 L L2 L1 D D KPH06-00 39.6 19.5 10 10 6 12.8 6 M M L KPH08-00 44.4 21.5 26 18 10 15.2 8 K KPH10-00 48.6 24 41 29 15 18.5 10 KPH12-00 50.6 25 58 46 18 20.9 12 M Note 1) D indicates the maximum diameter.

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)]

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)]

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -

Supply voltage for sensor 24 VDC Max. supply current for sensor 0.2 A/1 point, 0.9 A/1 unit Current consumption 100 mA or less (inside of Input unit) Input resistance 5.6 k Rated input current 4 mA or less 17 V or more/2.5 mA or more 17 V or more/2.5 mA or more ON voltage/ON current (Between input terminal and (Between input terminal and 0 V for sensor) +24 V for sensor) 7 V or less/1 mA

Load voltage Auto switch model Lead wire length (m) 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Wiring (output) Special function Tie-rod mount Type Electrical entry Applicable load Pre-wired 40 to 100 32 40 to 100 32 Band mount AC DC None connector G59 G5P K59 M9N 3-wire (NPN) F59 5 V, 12 V IC circuit M9P Grommet 3-wire (PNP) 24 V F5P M9B 12 V 2-wire Reed auto switch Solid state auto

5 V, 12 V 3-wire (PNP) 24 V Grommet 12 V 2-wire 100 V, 200 V Reed auto switch Solid state auto switch 3-wire (NPN) Terminal conduit 12 V 2-wire 3-wire (NPN) Relay, PLC IC circuit Yes 5 V, 12 V Diagnostic indication (2-color indication) 3-wire (PNP) 2-wire 24 V 12 V Grommet 3-wire (NPN) 5 V, 12 V 3-wire (PNP) Water resistant (2-color indication) 2-wire 12 V 4-wire (NPN) 5 V, 12 V IC

Series VXR21/22/23 Dimensions Normally Closed: VXR210/220/230 Normally Open: VXR212/222/232 Grommet: G Port size Conduit: C DIN terminal: D Cable 6 to 12 Conduit terminal: T Model Grommet Electrical entry Conduit Conduit terminal DIN terminal Q N 59 60 60 Port size P Rc N Q L K J H F E A B C D M 74 (81) 88 (98) 90 (100) N M 67 (74) 80 (90) 82 (92) M 67 (74) 80 (90) 82 (92) N M 67 (74) 80

Tubing for AD27-D: I.D. 2.5 (3/32") or larger, Length 5 m (200 inch) or shorter Tubing for AD37, 47(N)-D: I.D. 4 (3/16") or larger, Length 5 m (200 inch) or shorter Tubing for AD38, 48(N)-D: I.D. 6.5 (1/4") or larger, Length 5 m (200 inch) or shorter Air Source Warning (1) Use clean air.

Tubing for AD27-D: I.D. 2.5 (3/32") or larger, Length 5 m (200 inch) or shorter Tubing for AD37, 47(N)-D: I.D. 4 (3/16") or larger, Length 5 m (200 inch) or shorter Tubing for AD38, 48(N)-D: I.D. 6.5 (1/4") or larger, Length 5 m (200 inch) or shorter Air Source Warning (1) Use clean air.