500 25 50 100 200 300 500 Outlet air flow rate L/min(ANR) 6 12 25 50 60 86 3 6 11 22 29 50 Purge air flow rate L/min(ANR) *Note3 Inlet air pressure MPa 0.7 Inlet air temperature oC 25 Inlet air saturation temperature oC 25 Ambient temperature oC 25 Dew point indicator purge air flow rate 1 L/min (ANR) {In the case of inlet air pressure 0.7MPa} *Note4 Regulator construction (about Type V)
DC(+) 5 OUT1 4 OUT2 3 FUNC 2 DC(-) 1 -19No.PS-OMU0002CN-D Z/ISE20A(F)-S/-R () DC(+) NPN 2 Max.28 V80 mA 1 V R15 V OUT1 1 k OUT2 S420 mA DC(-) 12 V 300 24 V 600 50 DC(+) -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) DC(+) -X () -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) -20No.PS-OMU0002CN-D -V/-T () DC(+) PNP 2 Max.80 mA 1 V T15 V OUT1 1 k OUT2 V420 mA DC(
Max. lead impedance: 300 (at power supply voltage of 12 VDC) Load impedance 600 (at power supply voltage of 24 VDC) Min. lead impedance: 50 Analog response time 20 ms Input type Non-voltage input: 0.4 V or less, Current consumption: 5.5 mA or less External input Input mode Zero-clear 5 Input time 30 ms or more -75No.PS-OMX1005 Product No.
(19 (38L(2 ) 0.50.05 Nm ,, A(ZS-46-A1) 38L A B(ZS-46-A2) 38L B -15No.PS-OMU0005CN-C (a)(a) (b) (ZS-46-B) +(ZS-46-D) 90 -16No.PS-OMU0005CN-C (-M5) 1/6~1/4 1~1.5Nm (ZS-46-N) -01-N01 23 3~5 Nm -C4L-C6L 1/61/4 1~1.5Nm -17No.PS-OMU0005CN-C -18No.PS-OMU0005CN-C () TU0425( 42.5) -19No.PS-OMU0005CN-C FG -20No.PS-OMU0005CN-C Z/ISE20B(F)-S/-R () NPN 2 Max.28 V80 mA 1 V R15 V 1 k S420 mA 12 V 300
12 V 300 24 V 600 DC(-) 50 DC(+) -V/-T () OUT1 PNP 2 OUT2 Max.80 mA 1 V DC(-) DC(+) -Y () -V/-T () OUT1 PNP 2 OUT2 Max.28 V80 mA 1 V DC(-) -23No.PS-OMU0008CN-D [] 3 0.2 [] / / OUT1 OUT1 OUT2 OUT2 [F10]30 () 1 3 1 3 5 (63 ) (3 ) () () (26 ) (28 ) (30 ) 3 () 3 -24No.PS-OMU0008CN-D ON OFF ON P_1 H_1 ON OFF [] ISE20C [P_1] OUT1 0.500 MPa [P_2] OUT2 0.500 MPa [
24 V 600 50 OUT2 FUNC DC(-) DC(+) OUT1 -E OUT2 PNP 1 Max.80 mA 1 V 1 k FUNC DC(-) DC(+) -F OUT1 PNP 1 Max.80 mA 1 V 12 V 300 24 V 600 50 OUT2 FUNC DC(-) -20No.PS-OML0002CN-G 1 1 1 1 ONOFF ON OFF ON P_1 H_1 [Pa] ON OFF [] -21No.PS-OML0002CN-G <> 1 [P_1][n_1] 1 1 -22No.PS-OML0002CN-G 2[P_2][n_2] (P1LP1H) P1L()P1H() (n1Ln1H) 1 -23No.PS-OML0002CN-G 2[
at 12 V power supply voltage 600 at 24 V power supply voltage Min. load impedance 50 -E PNP open collector 1 output Max. 80 mA Residual voltage 1 V or less Analogue voltage output Output impedance approx. 1 k -F PNP open collector 1 output Max. 80 mA Residual voltage 1 V or less Analogue current output Max. load impedance 300 at 12 V power supply voltage 600 at 24 V power supply voltage
24 V 600 50 -S/-R () NPN 2 Max.28 V80 mA 1 V -17No.PS-OMM0002CN-F -V/-T () PNP 2 Max.80 mA 1 V T15 V 1 k V420 mA 12 V 300 24 V 600 50 -V/-T () PNP 2 Max.80 mA 1 V -A NPN2 Max.28 V80 mA 1 V -B PNP2 Max.80 mA 1 V -18No.PS-OMM0002CN-F ONOFF () ON OFF ON5OFF 20 P 1 H_1 [Pa] ON OFF [s] -19No.PS-OMM0002CN-F <> (19) 1 [P_1][n_1] 1 1 2[P_2][n_2] 2 (P1L P1H ) P1L()P1H() (n1L
voltage suppressor of 24 VDC and 1.0 W or less (manufactured by SMC) Valve Output SY3000SY5000SY7000 VQC1000VQC2000VQC4000VQC5000 JSY1000JSY3000JSY5000 SV1000SV2000SV3000 S0700 Applicable valve series Output setting during communication fault HOLD / CLEAR Protection Short circuit protection Operating temperature range -10 to 50 oC Standard CE marked (EMC directive/RoHS directive) Weight 300
, 350, 400, 450, 500 nut made of stainless steel 25, 50, 75, 100, 125, 150, 175, 200, 250, XC8 XC9 XC14 XC15 XC22 Adjustable stroke/Extension adjustment 1 50, 63 300, 350, 400, 450, 500, 600 2 Adjustable stroke/Retraction adjustment 25, 50, 75, 100, 125, 150, 175, 200, 250, Change of trunnion bracket mounting position 80, 100 300, 350, 400, 450, 500, 600, 700 Change of tie-rod length Types
Compact Cylinder Double Acting, Single Rod Bore size: 056(9/16), 075(3/4), 106(1 1/16), 150(1 1/2), 200(2), 250(2 1/2), 300(3), 400(4) Series NCQ8 How to Order Without auto switch B 056 025 NCQ8 B 056 025 Z M9BW S NCDQ8 With auto switch Built-in magnet X-Option Nil XB6 XC4 Standard High temp.
Flow rate (l/min (ANR)) Inlet pressure (MPa) ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 100 200 300 400 500 600 Flow rate (l/min (ANR)) Inlet pressure (MPa) ARP40(K) ARP40(K) Rc1/2 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35
Speed Controller Cylinder Solenoid valve Tubing Silencer Maximum return speed (mm/s) 100 200 300 6 ASD230F CJ2 VJ500 TU0604 1 m AN11001 10 Mounting 16 Cylinder size Caution 20 1. If installing flow controls to valve ports, interference may occur with the fittings. Please consult the catalog before installing.
, 350, 400, 450, 500 Replacement Parts: Seal Kits 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit No. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.
Output specification Port size: (inch) Symbol Nil 1 2 Specification Series PF2D300 Series PF2D200/300 Series PF2D300 Applicable display unit (monitor) model 11 13 19 3/8 1/2 3/4 PF2D504 PF2D520 PF2D540 Output for display unit Output for display unit + analog output (1 to 5 V) Output for display unit + analog output (4 to 20 mA) Specifications for Sensor Unit Model PF2D504 PF2D520 PF2D540
Double acting, Single rod Fluid Air Proof pressure 1.05 MPa Maximum operating pressure 0.5 MPa Minimum operating pressure Note 1) 0.005 MPa 10 to 80C Ambient and fluid temperature Cushion Rubber bumper (Provided as standard) Lubrication Note 2) Not required (Non-lube) Rod end thread Female thread Rod end thread tolerance JIS class 2 +1.0 0 Stroke length tolerance Piston speed Note 3) 0.3 to 300
400 500 600 700 800 900 1000 1200 1400 1600 1800 2000 MY3A/3B 3000 16, 25, 40, 63 CAT.S20-153 English cat.no.ES20-153 Mechanical Joint Rodless Cylinder/Compact and Low Profile Series MY2H/HT Series MY2H/HT Standard stroke (mm) Bore (mm) Model Guide 50 100 150 200 250 300 350 400 450 500 550 600 700 800 900 1000 1200 MY2C 16 Cam follower guide High precision guide Single axis MY2H 25 High
Vertical Horizontal l: Load eccentricity m Mounting position m L L to 100 to 300 Maximum speed mm/s to 500 to 100 to 300 to 500 Load eccentricity lmm 100 50 200 100 50 200 100 50 200 1 2 3 4 5 6 7 8 9 10 11 12 Selection graph L: Overhang (the distance from the cylinder shaft center to the load center of gravity) The direction of L can also be a diagonal direction .
N213 aOSilrtr 3 way.3 port sotenoid vatve NVZseies Rubber Seal Model 100/300/500 Low Power Consumption 1.8 WDC Compact Size, Large Flow Capacity Cv 0.05 0.5 High Speed Response Time -15 mSec (NVZ 100) Built-in One-Touch Fitting Manifolds Avaihbb Individual or Manifold Mounting Variat ions of C L Kl tmrn"..
Note 2) When compressor discharge concentration is 30mg/Nm Specifications Models Model AMG150 AMG250 Drain Catch Series AMG Compressed air 1.0MPa (145psi) Fluid Maximum operating pressure Rated flow rate Note) l/min (ANR) 300 750 Note) 0.05MPa (7psi) Min. operating pressure Proof pressure The AMG series is installed in air pressure lines to remove water droplets from compressed air.