trunnion 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80: 1400 100: 1500 Refer to pages 19 to 23 for cylinders with auto switches. 80, 100 Intermediate strokes not listed above are produced upon receipt of order.
Applicable stroke table Stroke [mm] Size 30 50 100 150 200 250 300 350 400 450 500 Manufacturable stroke range 25 15 to 400 32 20 to 500 25 - .
200 300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
AWD ITV VBA VE VY G AL Model Port size B J A F G H I C D E 100 100 60 60 73 73 230 230 431(481) 437(487) 59 63 166 162 117 117 3-M5 X 0.8 X 6 3-M5 X 0.8 X 6 AL800-12 to 14-1 AL900-20-1 11/4 / 11/2 2 ( ) With float switch 1.17-10
Cylinder Speed Chart Bore size Series CS1/CS2 Pressure 0.5 MPa, Load factor 50% Cylinder stroke 300 mm Average velocity (mm/s) System 125 140 160 180 200 250 300 1000 Vertically upward movement Horizontal movement 900 800 700 600 500 400 300 200 100 0 A 800 900 1000 700 600 500 400 300 200 100 0 B 900 1000 800 700 600 500 400 300 200 100 0 C 800 900 1000 700 600 500 400 300 200 100 0 D 800
Applicable Controller Power Supply Voltage 100VAC Specification Series LJ1H10 Series LJ1H20 LJ1H1021H-K (8mm lead) LJ1H2021F-K (5mm lead) 250 400 225 350 12kg 6kg 200 300 175 250 Speed (mm/s) Speed (mm/s) 150 8kg 13kg 125 200 10kg 100 150 14kg 75 100 15kg 50 50 25 0 100 200 Stroke (mm) 300 400 0 100 200 300 400 500 600 Stroke (mm) When an actuator is operated under conditions that exceed
Note 2) ( ): Denotes without sub-plate. 10-SV2000 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) Weight (g) Note 2) Flow rate characteristics Note 1) Port Valve model Actuation type M12 waterproof connector (Cable length 300 mm) size C[dm 3/(sbar)] b Cv C[dm 3/(sbar)] b Cv Single 159 (96) 2.4 0.41 0.64 2.8 0.29 0.66 2 position Double 163 (100) Closed center 1.8 0.47 0.50 1.8 0.40 0.47 3 position 10
Relationship between boundary value and display value of the level bar/switch point value bar and process data Distance type Level 1 Level 2 Level 3 Level 4 Level 4 60 or less (60 to 36) X+30 X+25 X+20 ISA-F (35 to 31) (30 to 26) (25 to 21) ISA3-G 300 or less X+150 X+125 X+100 Display (300 to 176) (175 to 151) (150 to 126) (125 to 101) value ISA3-H 500 or less X+300 X+250 X+200 Constantly
Cylinder Speed Chart Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series Average speed (mm/s) 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 It is when the cylinder is extending that is meter-out controlled by speed controller which
Weight Series Stroke[mm] 50 100 150 200 250 300 350 400 450 500 LEKFS16 Product weight[kg] 0.9 1 1.1 1.2 1.3 1.4 1.5 1.5 1.6 1.7 0.12 Additional weight with lock[kg] LEKFS25 Series Stroke[mm] 50 100 150 200 250 300 350 400 450 500 600 700 800 Product weight[kg] 1.7 1.8 1.9 2.1 2.3 2.4 2.5 2.6 2.8 2.9 3.2 3.4 3.7 0.26 Additional weight with lock[kg] LEKFS32 Series Stroke[mm] 50 100 150 200
(the value under the prescribed conditions) 0.8 0.7 0.6 Subsonic Critical pressure 0.5 0.4 0.45 0.45 Sonic 0.4 0.4 0.35 0.35 0.3 0.3 0.3 0.25 0.2 0.25 0.2 0.2 0.15 0.15 0.1 0.05 0.1 0.1 0.05 S = 0.54 VDW101 10 60 50 40 30 20 10 20 VDW 1.6 S = 1.2 125 100 75 50 S = 3.2 VDW202.3 350 300 250 200 150 100 50 S = 5.8 VDW203.2 600 500 400 300 200 100 S = 2.8 VDW302 300 250 200 150 100 50 VDW303
300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.
size Lubrication Model Rubber Air M3 x 0.5 12-CY3B6 6 300 50, 100, 150, 200 M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 12-CY3B15 15 1000 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 12-CY3B25 25 (Both sides) Non-lube 12-CY3B32 32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250
to 2000 300 to 400 5 300 to 2000 300 to 400 10 200 to 2000 200 to 300 15 200 to 2000 200 to 300 20 150 to 2000 150 to 250 30 50 to 2000 50 to 200 60 50 to 2000 50 to 150 (Note) After installation, verify the effects of static neutralization.
However, the lower limit (310) and the upper limit (320) setting cannot be established unless the following is satisfied. (300) Split range setting (320) (310) 40.0 % Example of connecting 2 units of IP8001 (unit 1 & unit 2) if (200)= (dir) is selected: 100% Unit 1 300=on 310=0.0 320=50.0 Stroke Unit 2 300=on 310=50.0 320=100.0 0% 0% 100% 50% Input current Fig. 24 If the input current range
d80 . %100 0 . 3 ~ "32 0. 1 8 "SO 0.58 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, SOD, 600 Allowable rotating torque "40 0.33 " 100 0.69 . ft Ibs max . . : 63 25,50,75,1 00,125,1 50 ,175,200, %50,.063 0.47 250, 300.350,400,450,500, 600 sr 25, so, 75. 100, 125. 150, 175 ,200,250, 300,350, 400, 450, 500, 600, 700 Nole 1) AbsOfbabte kinshc energy by cushIOn mechanIsm IS
70 to 100 Maximum pushing force LEP 10 (Basic) 100 50 to 100 LEP 10L (Compact) 100 60 to 100 Parameter protect 1: Common + StepData Changeable parameter 1: Common + StepData, 2: Common Enable switch 2: Disable Select 1:Enable or 2:Disable when using a teaching box Model name Part no. of each product Only the English characters and numbers are changeable.
10 30 205 4 3 2 20 Data 10 20 30 40 50 100 200 300 1 1 2 3 4 5 10 20 304050 100 200300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5 MPa 100 P = 0.5 MPa Load weight m(kg) Larger than 75st Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100
Movement MOD Speed Position Acceleration Deceleration Pushing force Trigger LV Pushing speed Moving force Area 1 Area 2 In position 0 1: Absolute 100 10 3000 3000 0 0 0 100 0 0 0.50 1 1: Absolute 100 100 3000 3000 0 0 0 100 0 0 0.50 2 1: Absolute 100 200 3000 3000 0 0 0 100 0 0 0.50 Note) The step data input range changes depending on the actuator model.
However, the lower limit (310) and the upper limit (320) setting cannot be established unless the following is satisfied. (300) Split range setting (320) (310) 40.0 % Example of connecting 2 units of IP8101 (unit 1 & unit 2) if (200)= (dir) is selected: 100% Unit 1 300=on 310=0.0 320=50.0 Stroke Unit 2 300=on 310=50.0 320=100.0 0% 0% 100% 50% Input current Fig. 25 If the input current range