Twists or crushing of connected tubes d. Hardness and deterioration of connected tubes e. Air leakage 192
64 30 24 113 68 30 24 0.1 2505-003 45.9 3 8 2506-004 50.0 1 2 310 88.5 48 35 2507-006 105.6 3 4 514 97.5 60 41 2508-010 129.6 1 57 54 22 19 2510-002 17.2 1 4 55 56 22 19 2511-003 17.2 3 8 0.05 0.02 0.01 0.005 0.002 Construction/Parts/Dimensions 50 100 200 500 1000 2000 5000 10 20 Port size Air flow (l/min (ANR)) Case (ZDC) Noise Level (Initial conditions) Hexagonal flats D (2507-006: Width
AME150 AME250 AME350 AME450 AME550 AME650 AME850 Model Note) 200 500 1000 2000 3500 6000 12000 Rated flow (l/min (ANR)) Port size (Nominal size B) 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , , , , , , , , , , Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.
D The setting time from when the signal of the connected pressure sensor reaches the set value, to when the ON-OFF output actually begins working. Delay time setting can prevent the output from chattering. Delay time Shows how precisely the pressure can be displayed or set.
D Shows how precisely the pressure can be indicated or set by the digital Pressure switch. When 1 digit = 1 kPa, the pressure is given with an increment Digit (Min. setting unit) of 1 kPa, e.g., 1, 2, 3,, 99, 100. E Energy saving automatic control Indicate that the vacuum pressure during adsorption is monitored and ON and OFF of the ejector is automatically controlled.
Panel mount adapter (Part No.: ZS-46-B) Panel mount adapter + Front protective cover (Part No.: ZS-46-D) Flow exceeding the upper limit of the set flow range is applied. Display unit setting Press the or button to change the display units. Warning Reset applied flow to a level within the set flow range. Power is supplied.
Ratio of discharge amount to fresh water (%) 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity (mPa s) mPas Silicone oil Lubricant Vegetable oil Water 60 to 80 1 6080 340 950 1500 3150 9800 Viscosity (mPa s) cp 0 100 1000 10 150 | 2650 45 | 2 3000 4500 Tomato juice Honey Medical barium Wooster source Cutting oil 4500 45 2000 to 3000 8 - 8.
Please check the following points in the regular maintenance, and replace the parts as necessary. a) Scratches, damage, wear, or corrosion b) Air leakage c) Squeezing or twisting of the tubing that is connected d) Hardening, deterioration or softening of the tubing that is connected e) Loosening of the nozzle 2.
LEF-D-2-1 For details, refer to the Web Catalog,) Note 4) Order auto switches separately. (For details, refer to the Web Catalog.)
Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz, when the actuator was tested in both an axial and perpendicular direction to the lead screw. (The test was performed with the actuator in the initialized state). Note 6) Maximum instantaneous power consumption (including the controller) is when the actuator is operating.
D: Modified errors in text. E: Contents are added. F: Contents are added. [July 2016] G: Contents revised in several places. [August 2019] H: Modified errors in text. [ November 2019] I: Contents revised in several places.
ITV2-OM00118-A P R O D U C T N A M E E/P Regulator (PROFIBUS DP type) MODEL/ Series/ Product Number ITV1000/2000/3000/2090-PR* Series Install and operate the product only after reading the Operation Manual carefully and understanding its contents. Specifically, read the safety instructions carefully. Keep this operation manual available whenever necessary.
ITV2-OM00095-C P R O D U C T N A M E E/P Regulator (DeviceNetTM type) MODEL/ Series/ Product Number ITV1000/2000/3000/2090-DE* Series Install and operate the product only after reading the Operation Manual carefully and understanding its contents. Specifically, read the safety instructions carefully. Keep this operation manual available whenever necessary.
ITV2-OM00116 P R O D U C T N A M E E/P Regulator (For RS-232C) MODEL/ Series/ Product Number ITV1000/2000/3000/2090-RC* Series Install and operate the product only after reading the Operation Manual carefully and understanding its contents. Specifically, read the safety instructions carefully. Keep this operation manual available whenever necessary.
ITV2-OM00114-B P R O D U C T N A M E E/P Regulator (CC-Link type) MODEL/ Series/ Product Number ITV1000/2000/3000/2090-CC* Series Install and operate the product only after reading the Operation Manual carefully and understanding its contents. Specifically, read the safety instructions carefully. Keep this operation manual available whenever necessary.
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2000 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing January, 2001 D-SMC.L.A.
(Value in the initial stage) Vibration resistance: No malfunction from test with 45 to 2000 Hz one sweep, to axis and right angle direction of main valve, each one time when pilot signal ON and OFF. (Value in the initial stage) JIS Symbol
(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.
1 Controller mounting * Select the LECP2 when setting the stroke range using the stroke adjustment unit or an external stopper. 11LEJS Nil Without cable (Without communication plug connector)*2 Nil Screw mounting D DIN rail mounting* 1 1.5 m 3 3 m 5 5 m S Straight type communication plug connector*2 25A* DIN rail is not included. Order it separately.
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: DMTU (D+M+T+U)