Note 9) External scratch marks and dirt are judged as good parts provided that they do not affect product performance.
Do not grip the piping port on the back side or the handles of the panel. 3. Do not pass over bumps, etc., with the casters.
Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction. 5. Do not use in a place subject to heavy vibration and/or shock. 6. The valve should not be exposed to prolonged sunlight. Use a protective cover. Note that the valve is not for outdoor use. 7.
Do not use in an atmosphere containing corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. Warning Air Supply 2. Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction. 1.
Do not use in atmospheres contacting corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not use in explosive atmosphere. 3. Do not use in locations subject to vibration or impact. 4. Do not expose to direct sunlight for an extended period of time. Protective cover should be used to shield. 5.
Do not use at location where a negative pressure is applied. The circulating fluid pump should be prepared by the customer. Note 4) The outline dimensions do not included protruding parts such as the foot flange and tube.
Analogue output: 4 to 20 mA Max. load impedance: 300 (12 VDC) 600 (24 VDC) Do not use the product for flammable or highly permeable fluids. A fire or explosion can result. Flow direction OUT side IN side Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.
Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these . 2. Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction. 3. Do not use in a place subject to heavy vibration and/or shock. 4.
Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.
(mm) 3.2 4 6 8 10 12 D Tubing I.D.
Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Our pressure switches do not have an explosion proof rating. Never use it in the presence of an explosive gas as this may cause a serious explosion. Panel Caution Panel mounting adapter A Panel mounting adapter B 1. Do not use in an environment with spattering liquid of oil or solvent. 2.
Do not mount the product in locations where it is exposed to radiant heat. 5. Do not use in dusty locations or where water, oil, etc., splash on the equipment. 6.
Do not mount the product in locations where it is exposed to radiant heat. 5. Do not use in dusty locations or where water, oil, etc., splash on the equipment. 6.
7 9.5 12 There is no difference in the frequency and the inrush and energized apparent power because a rectifying circuit is used in the AC (Class B, Builtin full-wave rectifier type).
Fig. 12-1 Correct position Fig. 12-2 Incorrect position 25/28 8. Made to order product A wide range of made-to-order products are prepared depending on operating environment and conditions. Refer to Table 13 for made-to-order products.
Do not use valves where there is direct contact with, or in atmospheres of, corrosive gases, chemicals, salts water or steam. 2. Do not use in an explosive atmosphere. 3. Do not use in locations subject to vibration or impact. Confirm the specifications for each series. 4 - 4. A protective cover should be used to shield valves from direct sunlight. 5.
Do not use pressure sensors with corrosive and/or flammable gases. 7. The applicable fluids are air, non-corrosive gas and non-flammable gas. Consult with SMC if the switch is to be used with other types of fluids. Caution Connection Caution 1. Do not drop, bump, or apply excessive impacts (100 m/s2) while handling.
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 5 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low tank fluid level 1 CH1 abnormal high circulating fluid temp. 2 Reservation
Front Mounting Rear Male Clevis, C Front Female Clevis, D Diameter E1 R W MF ZF FB CD EB L XD UB CB EW MR TR AO AT XA SA 32 48 32 16 10 130 7 10 65 12 142 45 26 26 9.5 32 10 4 144 142 40 55 36 20 10 145 9 12 75 15 160 52 28 28 12 36 11 4 163 161 50 68 45 25 12 155 9 12 80 15 170 60 32 32 12 45 12 5 175 170 63 80 50 25 12 170 9 16 90 20 190 70 40 40 16 50 12 5 190 185 80 100 63 30 16 190