The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529) SS5V2 MANIFOLD SV2000. MANIFOLD BLOCK ASSY. VALVE. SS5V2 NO SIZE RATING. .19052 lb. 21.
Positive Y EX210-SAS2 4 out Negative Y EX210-SAS3 VQ2000/4000 4 out Positive Y EX210-SAS4 8 out Negative Y EX210-SAS5 8 out Positive Y EX210-SAS6 LonWorks SEMI, Echelon Special Order ** VQ, SX, SY & SV 16 out N Negative 16 out Positive N VQ, SX, SY & SV EX120/121/122-SMJ1 CC-Link CLPA & Mitsubishi 16 out Positive Y VQ2000/4000/5000 EX124 (U, D)-SMJ1 16 out Positive N SQ1000/2000, SZ3000/50
With the 0.1 W specification, the vibration and impact resistance is 10/50 m/s2 or less. Note 3) With the low vacuum specification, the operating pressure range is 1.33 102 Pa to the maximum operating pressure.
Model Port size Recommended air flow (l/min (ANR)) Weight (kg) ZR 1 8 1 4 50 0.14 200 0.19 ZFA100 ZFA200 ZM The collected dust does not remain in the case. Dust is removed easily at the time the filter element is replaced. As a result, the dust does not remain in the case.
Model: VQC1000, Wiring: Double Wiring, Port Size: For 4mm One-touch fitting, Check Valve Option: w/ Back Pressure Check Valve
Model: VQC1000, Wiring: Single Wiring, Port Size: For 4mm One-touch fitting, Check Valve Option: w/ Back Pressure Check Valve
Model: 1000 (VQC1000), Wiring: D (Double Wiring), Port Size: C4 (For 4mm One-touch fitting), Check Valve Option: B (w/ Back Pressure Check Valve)
Model: 1000 (VQC1000), Wiring: S (Single Wiring), Port Size: C4 (For 4mm One-touch fitting), Check Valve Option: B (w/ Back Pressure Check Valve)
10 STA MFLD W/ EJECTOR. O84. 666.60000 lb. 4/5 PORT SOLENOID VALVE.
5 to 50 C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)5.5 MPa?5 to 50 C Note 1)20 times/minVertical upwards3/4?10.6 ?1101/45.6100
IS1000 01 S Port size Seal Option 01 N01 X201 R 1/8 NPT 1/8 None With seal Lead wire length 3 m Regulating pressure range 0.1 to 0.6 MPa Nil S X202 Lead wire length 3 m Regulating pressure range 0.1 to 0.6 MPa X215 16-9-1 2 Series IS1000 Construction 5 500 50 20 t u 0.1 0.2 y 0.3 0.4 i 58.5 MPa q Component Parts !
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), COVER PLATE, VALVE, SS5V2 MANIFOLD SV2000, 21, SS5V2 NO SIZE RATING, .30527 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529) SS5V2 MANIFOLD SV2000. GAUGE ASSEMBLY. VALVE. SS5V2 NO SIZE RATING. .02885 lb. 21.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529) SS5V2 MANIFOLD SV2000. CLIP. VALVE. SS5V2 NO SIZE RATING. .32758 lb. 21.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529) SS5V2 MANIFOLD SV2000. SILENCER COVER. VALVE. SS5V2 NO SIZE RATING. .30527 lb. 21.
SV series: ES11-81 Compact design with high flow capacity Model (Series) SV1000 SV2000 SV3000 SV4000 Flow characteristics Note) Applicable cylinder size (mm) Manifold pitch (mm) b C[dm3/(sbar)] Cv can operate independently. the number of stations are required.
SV series: ES11-81 Compact design with high flow capacity Model (Series) SV1000 SV2000 SV3000 SV4000 Flow characteristics Note) Applicable cylinder size (mm) Manifold pitch (mm) b C[dm3/(sbar)] Cv can operate independently. the number of stations are required.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), MFLD BLOCK, SGL WIRING, VALVE, SS5V2 MANIFOLD SV2000, 21, SS5V2 NO SIZE RATING, .18304 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529) SS5V2 MANIFOLD SV2000. MFLD BLOCK, DBL WIRING. VALVE. SS5V2 NO SIZE RATING. .14960 lb. 21.