40 510 30 50 70 100 200 300 2 10 30 50 70 100 200 300 Eccentric distance L (mm) Eccentric distance L (mm) Continuous line: Operating pressure 0.4MPa or more Selection graph to 700mm/s Selection Example: Vertical Upward Mounting 100 50 Selection conditions Mounting: Vertical upward (lifter) Maximum speed: 500mm/s Load weight: 40kg Eccentric distance: 80mm Load weight m (kg) Refer to graph
(Cylinder: CYP32-200, Work piece weight: 5kg, Average speed: 2000mm/s) Note 5) The data above provide a guide for selection but is not guaranteed. Cylinder tube Piping port variations provide a high degree of freedom Piping port positions can be selected to accommodate the installation.
(Cylinder: CYP32-200, Work piece weight: 5kg, Average speed: 2000mm/s) Note 5) The data above provide a guide for selection but is not guaranteed. Cylinder tube Piping port variations provide a high degree of freedom Piping port positions can be selected to accommodate the installation.
(Cylinder: CYP32-200, Work piece weight: 5kg, Average speed: 2000mm/s) Note 5) The data above provide a guide for selection but is not guaranteed. Cylinder tube Piping port variations provide a high degree of freedom Piping port positions can be selected to accommodate the installation.
Voltage 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC Electrical entry G C T TL Grommet Conduit Conduit terminal Conduit terminal with indicator light Clip part no. Note) Indicate the valve model no. as a label will be attached to the clip.
Coil rated voltage (V) 24, 6, 12, 48 Allowable voltage fluctuation (%) Power consumption (W) [Current mA] 15 to +10% of rated voltage 1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)] Note) DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Inrush Note) Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200
, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 3000 32 3000 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke type (XB11) applies to the strokes exceeding 2000 mm.
MK-A012 MK-A016 Bore size (mm) 12 16 20 25 32 40 50 63 12 70 87 16 100 123 20 250 290 25 280 320 32 500 525 40 595 640 50 1100 1350 63 1520 1805 Clamp bolt, Hexagon socket head cap screw, Hexagon nut, Spring washer MK-A020 MK-A032 Additional Weight MK-A050 Unit: g 63 17 46 25 350 531 50 7 46 13 350 345 32 7 21 5 200 166 40 6 21 7 200 198 25 7 10 3 100 153 12 13 16 32 20 6 10 2 100
Made to Order How to Order 2 F 06 A 200 AS Lubricant: Vaseline -X12 Example) AS2002F-04A-X12 Body size Made to Order Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X21 100 M5 standard 200 1/8 standard 205 1/4 standard 300 3/8 standard 400 1/2 standard Push-lock type Example) AS2002F-04A-X21 * Not particle-free Applicable tubing O.D.1 Metric size Inch size 23 3.22
Maximum operating pressure Pv (MPa) 1 5 0.3 Model Allowable load mass mv (kg) Model Cushion Stroke Stroke (mm) CYV15 CYV32 CYV15 CYV32 25 30 8-18-6 Rodless Cylinder for Vacuum Series CYV 15, 32 How to Order MX CYV 15 200 MTS MY CY Standard stroke Bore size MG 15 32 15 mm 32 mm Standard stroke (mm) 100, 150, 200, 250 300, 350, 400, 450 500, 600, 700 Bore size (mm) 15, 32 CX DSpecifications
200 Unclamped position T200 S200 240 240 T240 S240 270 T270 Limit switch Clamped position Note) This product does not include the limit switch.
Turn another 90 from the position where tightening is felt by hand.
Maximum operating pressure Pv (MPa) 1 5 0.3 Model Allowable load mass mv (kg) Model Cushion Stroke Stroke (mm) CYV15 CYV32 CYV15 CYV32 25 30 8-18-6 6 Rodless Cylinder for Vacuum Series CYV 15, 32 How to Order MX CYV 15 200 MTS MY CY Standard stroke Bore size MG 15 32 15 mm 32 mm Standard stroke (mm) 100, 150, 200, 250 300, 350, 400, 450 500, 600, 700 Bore size (mm) Courtesy of Steven Engineering
Table 3-3 Power supply cable and Earth Leakage BreakerRecommended Recommended earth leakage breaker Model Power supply Sensitivity voltage Cable qty. x size Rated Rated of leak voltage current current [V] [A] [mA] 1-phase 200-230V AC (50/60Hz) 3 cores x12AWG HRS040-A-20 200, Recomm 230 20 30 Terminal (3 cores x3.5mm2) HRS040-W-20 block ended (including ground) screw crimp diameter terminal
Table 3-3 Power supply cable and Earth Leakage BreakerRecommended Terminal block Recommended earth leakage breaker screw Recom Tightening Model Power supply Cable qty. x torque Rated Sensitivity Rated diameter mended voltage size voltag of leak current crimp e current [A] terminal [V] [mA] 3coresx12AWG 1-phase (3 cores 200-230V AC HRS050-A-20 200, x3.5mm2) (including 230 20 30 M4 5.5-4 1.5Nm
Item XLH-25 XLH-40 XLH-50 Rated voltage of the heater 90 to 240 ACV Heater assembly number XLA25-60S-1 XLA25-60S-1 No. of heater assemblies 1 pc. 1 pc. H4 S y m b o l Initial power / Power 100 VAC 200/40 200/50 200 VAC 800/40 800/50 consumption (W) Heater assembly number XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 1 pc. 1 pc. 1 pc.
Weight Series Stroke[mm] 50 100 150 200 250 300 350 400 450 500 600 700 800 LEKFS25 Product weight[kg] 1.7 1.8 2.0 2.1 2.3 2.4 2.5 2.6 2.8 2.9 3.2 3.5 3.8 0.26 Additional weight with lock[kg] LEKFS32 Series Stroke[mm] 50 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 Product weight[kg] 3.6 3.8 4.0 4.2 4.5 4.7 4.9 5.1 5.3 5.5 5.9 6.3 6.7 7.1 7.5 0.53 Additional weight with lock[kg
(mm) 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Weight(kg) 3.15 3.35 3.55 3.75 3.95 4.15 4.35 4.55 4.75 4.95 5.15 5.35 5.55 5.75 5.95 6.15 6.35 6.55 6.75 6.95 0.53 Additional weight for lock(kg) 4 Model LEFS40 Stroke(mm) 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 Weight(kg) 5.37 5.65 5.93 6.21 6.49 6.77 7.15 7.33
Laser marking Hexagon wrench Features 2 Rodless Cylinder for Vacuum Series CYV How to Order CYV 15 200 Rodless cylinder for vacuum Standard stroke Bore size 15 32 15mm 32mm Standard stroke (mm) 100, 150, 200, 250 300, 350, 400, 450 500, 600, 700 Bore size (mm) 15, 32 Specifications 15 32 Bore size (mm) Atmosphere to 1.3 x 10Pa (ABS) Operating environment pressure Air and inert gases Operating
Bore size [mm] (Pressure receiving diameter) 4 6 10 16 20 Operating pressure range [MPa] Mass of moving parts [g] 4 8 24 62 103 Thrust control standard [N] 0.01 to 8 0.03 to 19 0.08 to 50 0.20 to 140 0.30 to 200 Stroke [mm] 0.001 to 0.7 10 (Excluding the mass of moving parts) 1170 (Metal Seal Type/Single Acting) /4, 6, 10, 16, 20 control range of 0.01 N to 200 N Application Examples: For