40 Pilot EXH 177.5 14 (3(R) port) 2 x 5.5 Mounting hole 2 x 1/4 (: Thread type) 1 3 Manual override 23 9 19 3(R) port 1(P) port Conduit terminal VFN212N-lTll-02l-l-l Grommet VFN212N-lGll-02l-l-l Surge voltage suppressor (With "S") 137 41.7 300 19 23 Indicator light (With "Z") 74(Without "Z": 64) 64(Without "Z": 54) Grommet terminal VFN212N-lEll-02l-l-l Lead wire O.D. 3.5 at max.
Series VX Solenoid Coil Assembly How to Order VX021 C 001 01 B Rated voltage (1) VX solenoid coil assembly 02 =+4 7> 01 =+4 7> Electrical option Application 03 =+4 7> Nil # 04 =+4 7> S 5 % * ,* -> -/& 05 ( ! 001 # ) # ) #' ) L 5 % ) / *% ' 06 ! 002 003 Z 5 % *%+ * ,* -07 ( =+4 7> 08 (?
ARP30-02BG For 0.4 MPa setting 1 l/min (ANR) or less (at P2 = 0.4 MPa) Air consumption Ex.) ARP30-02BG-1 For 0.2 MPa setting 0.6 l/min (ANR) or less (at P2 = 0.2 MPa) Ex.)
,lodular type FFL Combinalion Recommended for control of pilot signal: NIT 200 ' OO 2G Elecko-pneumalic regulator Ref. catalog N8-01 HOW TO ORDER x x T I I L aterial I t NIL NBB (Buna) I S Copper Free Extarnal I TFPM (Viton) High Tamperature tP300 42 0 -T-T | l t l Supply & Output Preasure Gauge I t00 no gauge Operution 01 2kgllcrf r bsingte Acring 02 3 kgf/cm'z 03 10kg /cnf 04 4 kgf/cm'?
ARP30-02BG For 0.4 MPa setting 1 l/min (ANR) or less (at P2 = 0.4 MPa) Air consumption Ex.) ARP30-02BG-1 For 0.2 MPa setting 0.6 l/min (ANR) or less (at P2 = 0.2 MPa) Ex.)
(ANR)) Air flow rate (l /min (ANR)) AMG550 3 4 B AMG250 1 4 B Max. flow line Pressure drop (MPa) Max. flow line Air flow rate (l /min (ANR)) Air flow rate (l /min (ANR)) AMG650 1 AMG350 3 8B B Max. flow line Pressure drop (MPa) Pressure drop (MPa) Max. flow line Air flow rate (l /min (ANR)) Air flow rate (l /min (ANR)) 14-20-4 3 Water Separator Series AMG Construction AMG150 to AMG650 AMG850
Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.
Technical Data for Operation The instruction manuals should be read before using the Series CE1 scale cylinder and CEU1 3 point preset counter. 4.4-5 Stroke Reading Cylinder 12, 20, 32, 40, 50, 63 Series CE1 How to Order CE1 L 32 200 Mounting Number of auto switches Both ends tapped (standard) 2 Bore size B Auto switch S 1 12 20 32 40 50 63 12mm L F G D Without auto switch Foot 3 3 20mm
Model AMD450 AMD550 AMD650 AMD850 AMD150 AMD250 AMD350 Rated flow (l/min (ANR))(1) 2000 3500 6000 12000 200 500 1000 Port size (Nominal size B) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 3/8, 1/2, 3/4 1/2, 3/4, 1 31/2, 1 1, 11/2 11/2, 2 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Standing Style/Model Model AMD1000 Rated flow (l/min(ANR)) 8000 AMD800 24000 AMD900 40 Port size (Nominal size B) 2B Flange 2B
VK300-37-2-01 VK300-37-2-02 VK300-37-2-07 VK300-37-4-51 VK300-37-4-06 VK300-37-3-05 VK300-37-3-53 Rated voltage 100VAC 200VAC 240VAC 6VDC 12VDC 24VDC 48VDC Rating symbol A1 A2 A3 LW06 LW2 LD4 LD8 DIN terminal Circuit diagram for connector with light The bushing may be damaged if the tightening torque of 0.8Nm is exceeded.
D 1 10 Stations Common supply and exhaust M a i n t e n a n c e a n d a d j u s t m e n t i s p o s s i b l e w i t h o u t d i s a s s e m b l y o f the manifold H O W T O O R D E R NZM V A C U U M E J E C T O R M A N I F O L D (N)ZZM B NUMBER OF STATIONS 01 ... 1 Station 02 ... 2 Stations to 10 ... 10 Stations EXHAUST PORT 04 ... 1/2 06 ... 3/4 PORT THREAD Nil ...PT* Remove (N) when ordering
Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Specications Model HRSH100-Al-20-l HRSH150-Al-20-l HRSH200-Al-20-l HRSH250-Al-20-l HRSH300-Al-20-l Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.27 2.1 2.1 2.8 2.8 Control method PID control Ambient temperature/Altitude Note 1), 9) C Temperature: 20 to 45, Altitude: less than 3000
Please change the parameter in the initial setting. *3 The minimum unit of the travel distance of the actuator should be 1 [m]. *4 When the motor mounting position is right side parallel (LEY*R / LEYG*R) or left side parallel (LEY*L / LEYG*L), the rotation direction selection is 0(+: Counter motors side). -31- Recommended Value of acceleration time constant of Point table No.1 [LEY] LEY25
2 SET SUP DIN UP DOWN OUT UP ( ) ON/OFF SET ( ) DOWN ( ) ON/OFF SUP () OUT () DIN DIN / ON/OFF() ON () -14No.PS-OMR0001CN-J 2 (ISA3) ISA3-F ISA3-G ISA3-H (5 m ) 0.010.03 mm 0.020.15 mm 0.050.30 mm () 1 060 2 10300 2 30500 2 () 1 1 100200 kPa () 3 -20220 kPa 600 kPa 1.5 4 5 L/min 12 L/min 22 L/min DC24 V 10(p-p)10() 25 mA 1 (NPN PNP) 10 mA 26.4 V 1 V (10
min 12 L/min 22 L/min DC24 V 10(p-p)10() 25 mA 2 (NPN PNP) 10 mA 26.4 V 1 V (10 mA ) 2 LCD 3 7 (/) 6 7 () IP67 8 050 -2070 () 3585RH() AC1000 V 50/60 Hz 1 2 M(DC500 V ) Rc1/8 C 4 6 G1/8(ISO1179-1) F G1/8(ISO1179-1) -15No.PS-OMT0001CN-E 2 ISA3-F ISA3-G ISA3-H M12-4 4 4 5 m 0.72 mm 1.14 mm M12-4 4 4 1.14 mm 23 8 6 5 m46 14 6 5 m 0.50 mm 1.00 mm(26 )
AME150 AME450 AME650 B 1 8B 1B 1 2 0.1 MPa 0.1 MPa 0.1 MPa Max. flow line Max. flow line Pressure drop (MPa) Pressure drop (MPa) Pressure drop (MPa) Max. flow line Air flow rate (l /min (ANR)) Air flow rate (l /min (ANR)) Air flow rate (l /min (ANR)) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800)
/min (ANR)) Air flow rate (l /min (ANR)) AMH550 AMH250 B B 3 4 1 4 Inlet air pressure Air pressure Pressure drop (MPa) Pressure drop (MPa) Max. flow line Max. flow line Air flow rate (l /min (ANR)) Air flow rate (l /min (ANR)) AMH650 AMH350 B 1B 3 8 Inlet air pressure Air pressure Pressure drop (MPa) Pressure drop (MPa) 0.5 Max. flow line Max. flow line Air flow rate (l /min (ANR)) Air flow
Maintenance Caution Model Connection (Flange) 2B 8B C 2B/3B/4B 500 A 330 B 300 D 1070 E 1200 F 1290 G 20 H 720 M16 X l 400 Anchor bolt M20 X l 500 AMF800 AMF900 400 550 560 745 300 300 1070 1090 1230 1320 1335 1450 24 24 q It is not possible to indicate a definite replacement interval for the element because it varies with the odor concentration of the compressed air.
A80CN 1) Lead wire symbols 0.5m: 3m: L 5m: Z : N 2) This rotary cylinder is not an improved product in water resistant ability.
: D Manual override (Non-locking) 2-Rc 1/8 1(P) port Applicable cable O.D. 4 to 6.5 MAX.10 71.5 78.5 71 Indicator light (Type DZ only) 67.5 59 32 17 2 2-4.5 (Mounting hole) P mPm P 19 35 Pg.7 2-Rc 1/8 1(P) port A A A 11 20 26 49 300 (lead wire length) 1 P = 19 13.5 L2 5.5 L1 47.5 11 5 n-Rc 1/8, M5 x 0.8 2(A) port 19 35 n-Rc 1/8 3(R) port 47.5 11 R R P = 19 19 L Dimension n: Stations n L