SMC Corporation of America
Elite Part Number Search
Search Results "NALT-5-IS-2"

(2 position) Twist selector (3 position) Foot pedal Push-pull P . 5-6-8 P . 5-6-12 P . 5-6-20 Effective area (mm2) Number of ports 1 2, 3 Poppet 2.5 2, 3 Poppet 19 2, 3 Poppet Function 5-6-2 Mechanical Valves Series VM Mechanical Valves SA VA VM400 VZM500 VZM400 VFM300 VFM200 VM800 SA 21 x 35 x 53 18 x 28 x 87 18 x 30 x 91 26 x 35 x 94 23 x 40 x 115 30 x 40 x 57 VA VM VR VH VHS Roller lever

The warranty period of the product is 1 year in service or 1.5 years after the product is delivered, whichever is first.2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2.

Air gripper .13 4-2. 3-port solenoid valve .14 4-3. Auto switch .15 5. Operating method or operation .16 5-1Precautions for Design .16 5-2. Installation .16 5-3. CRX Plug-in software .20 5-4. Air supply .28 5-5. Piping .28 5-6. Operating environment .29 5-7. Lubrication .29 6.

SI unit Refer to fault SI unit PWR LED is OFF malfunction No.1 SI unit Refer to fault PWR (V) LED is OFF No.2 Yes No SI unit SI unit Refer to fault SF LED is ON BF LED is ON No.3 Refer to fault No.4 SI unit SI unit Refer to fault BF LED is flashing SF LED is ON No.5 Refer to fault No.6 Group of valves Refer to fault not working No.7 All valves and Refer to fault valve LEDs are not operating

LEY63 LEY63D Lead symbol A B C L A B C Series Lead 5(2.86) (Including pulley 20 10 5 20 10 5 (Pulley ratio 4/7) ratio) Initial value Recommended value Parameter *1,*2 Para.

Note 2) The FN4 series is equipped with two pressure gauges.

ARM 2 2 3 3 3 4 4 5 5 6 6 2 2 2 3 3 4 4 5 5 6 6 1 2 1 2 3 1 2 1 2 1 2 A B C A B A B A B A B 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 19 x 16 12 x 10 25 x 22 19 x 16 1/4" x 5/32" 3/16" x 1/8" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 1/2" x 3/8" 3/8" x 1/4" 3/4" x 5/8" 1/2" x 3/8" 1" x 7/8" 3/4" x 5/8" SMC SMC SMC ARP P U Panel mount union Union IR-A IR SMC IRV : Basic size : With reducer

Load Load Switch 1 Switch 1 Blue [Black] Blue [Black] Brown [Red] Brown [Red] Switch 2 Switch 2 Blue [Black] Blue [Black] Power supply voltage Residual voltage Leakage current Load impedance Load voltage at OFF = x 2 pcs. x Load voltage at ON = x 2 pcs. = 1mA x 2 pcs. x 3k = 6V = 24V 4V x 2 pcs. = 16V Example: Power supply is 24VDC Voltage decline in switch is 4V Example: Load impedance

1 2 2 1 2 m 2 1 2 1 2 Kinetic energy E1 m 2 RB T S R Thrust energy E2 m g S F S + m g S F S m g S Absorbed energy E E1 + E2 E1 + E2 E1 + E2 E1 + E2 Note 2) E 2 2 E 2 2 E 2 2 E 2 2 Equivalent mass Me Note 1) This is the momentary speed at which an object is impacting against a shock absorber.

Refer to Best Pneumatics No. 2-1 for details. 361 CH2E/CH2F/CH2G/CH2H Series Construction @7 q y i @8 !4 #1 @6 @1 u @0 #0 o w !5 !8 !9 !6 !7 @9 !2 @2 @4 t e !0 CH2G Series !3 @3 r @5 !

Doc. no.C96N-OM0197Q PRODUCT NAME Cylinder with lock MODEL / Series / Product Number CP96N*32&100-*C Contents Safety Instructions P.2 1. Product Specifications P.4 1-1. Cylinder specifications P.4 1-2. Lock unit specifications P.4 1-3. Stop accuracy P.4 1-4. Precautions on model selection P.5 2. Installation and Handing P.9 2-1. Air supply P.9 2-2. Design P.10 2-3. Mounting P.11 2-4.

5 V, 12 V IC circuit Diagnostic indication (2-color indication) Grommet 2-wire 12 V Water resistant (2-color indication) With diagnostic output (2-color indication) 4-wire (NPN) 5 V, 12 V IC circuit Lead wire length symbols: 0.5 mNil 3 m L 5 m Z None N Since there are other applicable auto switches than listed, refer to page 10-2-102 for details.

a 48.5 23 60 142 0 86 1 . 5 1 5 1 0 5 59 130 58 254 58 52 17.5 66 3/. 16 37 55 1 5 23 70 208 0 102 1 3 . 5 1 8 130 76 160 71 296 80 65 21.5 80 4D 56.5 1 5 25 80 226 0 1 6 1 3 . 5 1 8 1 5 0 92 180 3 1 5 80 65 2 1 . 5 81 $eries CLA lllmensio Rear Flange Type/CLAG with Rod Boot tvt14x1.5 M 1 8 X 1 . 5 rv18x1.5 M22)r.1.5 t\426X1.5 I n 2 0 27 ,/. 42 I I 20 45 153 8 60 9 1 2 80 42 100 5 1 2 1

from the VY Valve. 02 14 2.0 3 03 38 3.3 body Ported Type 04 12 3.9 Terminal Designations are as follows: 04 12 7.2 5 06 34 8.9 1 = 24v Power Supply 2 = Control Signal 3 = Common Negative for both power and signal. 10 1 10 5% 2% + -2% 7 10 1 114 17 12 114 18 9 14 112 2 33 20 2 37 Courtesy of Steven Engineering, Inc. !

Note 1) The tightening torque for the hexagon socket head cap screw (M3 x 14 L) is 0.5 to 0.6 Nm. Note 2) The tightening torque for the hexagon socket head cap screw (M2.5 x 5 L) is 0.25 to 0.35 Nm.

Also, if pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. 8 Wrap this way. Sealant tape Leave 2 threads exposed. Fig. 2 Sealant tape 2-5.

pressure is: kPa for positive pressure is: MPa (kPa for 500 kPa range model) Options Option products Model Note Power and output cable ZS-28-A Length 2 m Bracket ZS-28-B With set screws M3 x 5 L (2 pcs.)

Applicable piping size Applicable tubing size (mm) 2 2 2 2 2 3 3 3 3 3 3 3 3 4 4 4 4 5 5 5 6 6 6 Size No.

Auto switch 1 Auto switch 1 Blue Blue Brown Brown Auto switch 2 Auto switch 2 Blue Blue Load voltage at ON = Power supply voltage Residual voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 kW = 6 V Example: Load impedance is 3 kW. Leakage current from auto switch is 1 mA.