SMC Corporation of America
Elite Part Number Search
Search Results "MLGCMB20-450-D"

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Air cushion, Operating Pressure(MPa

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Air cushion, Operating Pressure(MPa)

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Air cushion, Operating Pressure(MPa

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Rubber cushion, Operating Pressure(

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Rubber cushion, Operating Pressure(MPa

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Allowable Load Weight: 2 [450 lbf (2 KN)], Stroke: 12 (12mm, MACM2), Table Option: G (Stainless Steel, Polished Finished), Sensor Type: Unsupported, Relief Port: No

Allowable Load Weight: 2 [450 lbf (2 KN)], Stroke: 12 (12mm, MACM2), Table Option: N (Cast Nylon), Sensor Type: Unsupported, Relief Port: No

Allowable Load Weight: 2 [450 lbf (2 KN)], Stroke: 12 (12mm, MACM2), Table Option: U (Ultra High Molecular Weight Polyethylene), Sensor Type: P (Port Side Photo Sensor Mounted Type), Relief Port: No

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VALVE, MEDIA FOR MFLD, AIR, 3 PORT SOLENOID VALVE, 450 lb

external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC , Response time (0.5MPa) w/o indicator light & surge voltage suppressor: 32ms or less , Ambient & fluid temperature: 50°C, VALVE, SOL, 4/5 PORT SOLENOID VALVE, 450

IP65 enclosure , Conforms to UL94V-0 flame resistance , Special construction improves service life when compared with current shading coil , Power consumption: size 1 - 4.5w; size 2 - 7w; size 3 - 10.5w , Body material: aluminum, resin, 2 PORT VALVE, 2 PORT VALVE, 450 lb

Safety cannot be assured in the case of unexpected malfunction. 0 2 4 6 8 10 Input No. 12 14 No corrosive gas or dust Operating atmosphere 250 g Weight 450 g Provide grounding to assure the safety and noise resistance of the Serial System. Individual grounding should be provided close to the product with a short cable. 138 Seal cap (for M8 connector socket): 16 pcs.

(Note1) (Petroleum,Water-glycol, Emulsion,Phosphoric ester) Applicable model FH100-06 FH100-08 FH100-10 FH100-12 FH100-16 FH100-20 FH100-24 INOUT Port size (Rc) 3/4B 1B 1 1/4B 1 1/2B 2B 2 1/2B 3B Drain port size M162 Rated flow Paper 50 80 120 160 260 450 600 rate Micromesh 60 100 150 200 300 550 700 (L/min) Operating pressure 1.0MPa Operating temperature 80oC Nominal filtration 1.

Faster Average speed [mm/s] Measuring conditions Supply pressure: 0.55 MPa 0 50 100 150 125-250 160-300 Bore size-Stroke 200-300 250-450 320-530 Speed adjustment rotary switch set value 0 5 9 Mounting: Vertical downward Load: no-load Operating direction: Upward *1 The average speed value is the stroke divided by the full stroke time.

End-lock type (Cylinder with end lock) 16 20 25 32 40 Lock position Single side (selectable), both sides Holding force (max.)N 110 170 270 450 700 Stroke fine adjustment range (mm) 0 to -5.6 0 to -6 0 to -11.5 0 to -12 0 to -16 Backlash 1mm or less Manual release Possible (Non-locking type) Warning 1.

It that case, install the tube and plug, and pull the fitting out together with them. 450 Series ARM5A/5B/5S Replacement Procedure of Diaphragm 3 3. Replacement of Manifold Stations (Common Supply Specification) Change of manifold stations and common supply block Content Actuators Modular F.R.L.